Field Validation of a Novel Passive Sampler for Dissolved PFAS in Surface Waters

被引:15
|
作者
Gardiner, Christine [1 ]
Robuck, Anna [1 ]
Becanova, Jitka [1 ]
Cantwell, Mark [2 ]
Kaserzon, Sarit [3 ]
Katz, David [2 ]
Mueller, Jochen [3 ]
Lohmann, Rainer [1 ]
机构
[1] Univ Rhode Isl, Grad Sch Oceanog, Narragansett, RI 02882 USA
[2] US EPA, Atlantic Coastal Environm Sci Div, Narragansett, RI USA
[3] Univ Queensland, Queensland Alliance Environm Hlth Sci, Brisbane, Qld, Australia
关键词
Perfluorooctanesulfonic acid; Perfluorooctanoic acid; Sampling rate; Wastewater treatment plan effluent; Surface water; Narragansett Bay; POLYFLUOROALKYL SUBSTANCES; IN-SITU; STATISTICAL TREATMENTS; DIFFUSIVE GRADIENTS; CALIBRATION; SULFONATES; SYSTEMS;
D O I
10.1002/etc.5431
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Numerous per- and polyfluoroalkyl substances (PFAS) are of growing concern worldwide due to their ubiquitous presence, bioaccumulation and adverse effects. Surface waters in the United States have displayed elevated concentrations of PFAS, but so far discrete water sampling has been the commonly applied sampling approach. In the present study we field-tested a novel integrative passive sampler, a microporous polyethylene tube, and derived sampling rates (R-s) for nine PFAS in surface waters. Three sampling campaigns were conducted, deploying polyethylene tube passive samplers in the effluent of two wastewater treatment plant (WWTP) effluents and across Narragansett Bay (Rhode Island, USA) for 1 month each in 2017 and 2018. Passive samplers exhibited linear uptake of PFAS in the WWTP effluents over 16-29 days, with in situ R-s for nine PFAS ranging from 10 ml day(-1) (perfluoropentanoic acid) to 29 ml day(-1) (perfluorooctanesulfonic acid). Similar sampling rates of 19 +/- 4.8 ml day(-1) were observed in estuarine field deployments. Applying these R-s values in a different WWTP effluent predicted dissolved PFAS concentrations mostly within 50% of their observations in daily composite water samples, except for perfluorobutanoic acid (where predictions from passive samplers were 3 times greater than measured values), perfluorononanoic acid (1.9 times), perfluorodecanoic acid (1.7 times), and perfluoropentanesulfonic acid (0.1 times). These results highlight the potential use of passive samplers as measurement and assessment tools of PFAS in dynamic aquatic environments. Environ Toxicol Chem 2022;00:1-11. (c) 2022 SETAC
引用
下载
收藏
页码:2375 / 2385
页数:11
相关论文
共 50 条
  • [21] Silicone rubber sampler to measure dissolved gases in saturated soils and waters
    Jacinthe, PA
    Groffman, PM
    SOIL BIOLOGY & BIOCHEMISTRY, 2001, 33 (7-8): : 907 - 912
  • [22] Field performance of the Chemcatcher passive sampler for monitoring hydrophobic organic pollutants in surface water
    Vrana, Branislav
    Mills, Graham A.
    Leonards, Pim E. G.
    Kotterman, Michiel
    Weideborg, Mona
    Hajslova, Jana
    Kocourek, Vladimir
    Tomaniova, Monika
    Pulkrabova, Jana
    Suchanova, Marie
    Hajkova, Katerina
    Herve, Sirpa
    Ahkola, Heidi
    Greenwood, Richard
    JOURNAL OF ENVIRONMENTAL MONITORING, 2010, 12 (04): : 863 - 872
  • [23] Field performance of a novel passive bioaerosol sampler using polarized ferroelectric polymer films
    Therkorn, Jennifer
    Thomas, Nirmala
    Scheinbeim, Jerry
    Mainelis, Gediminas
    AEROSOL SCIENCE AND TECHNOLOGY, 2017, 51 (07) : 787 - 800
  • [24] Calibration and field validation of POCIS passive samplers for tracking artificial sweeteners as indicators of municipal wastewater contamination in surface waters
    Tamanna Sultana
    Chris D. Metcalfe
    Environmental Monitoring and Assessment, 2022, 194
  • [25] Calibration and field validation of POCIS passive samplers for tracking artificial sweeteners as indicators of municipal wastewater contamination in surface waters
    Sultana, Tamanna
    Metcalfe, Chris D.
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2022, 194 (08)
  • [26] INEXPENSIVE SURFACE WATER DISSOLVED-OXYGEN SAMPLER
    SPENCE, LE
    PROGRESSIVE FISH-CULTURIST, 1974, 36 (01): : 26 - 26
  • [27] Method for the in Situ Calibration of a Passive Phosphate Sampler in Estuarine and Marine Waters
    O'Brien, Dominique S.
    Booij, Kees
    Hawker, Darryl W.
    Mueller, Jochen F.
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (07) : 2871 - 2877
  • [28] Field Trials of an Autonomous eDNA Sampler in Lotic Waters
    George, Scott D.
    Sepulveda, Adam J.
    Hutchins, Patrick R.
    Pilliod, David S.
    Klymus, Katy E.
    Thomas, Austen C.
    Augustine, Ben C.
    Huddleston Adrianza, Chany C.
    Jones, Devin N.
    Williams, Jacob R.
    Leinonen, Eric G.
    Environmental Science and Technology, 2024, 58 (47): : 20942 - 20953
  • [29] Dissolved mineral matter in surface waters
    Collins, WD
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1936, 17 : 452 - 453
  • [30] Validation of an passive atmospheric deposition sampler for polybrominated diphenyl ethers
    Gocht, Tilman
    Moeckel, Claudia
    Chaemfa, Chakra
    Thomas, Gareth O.
    Jones, Kevin C.
    JOURNAL OF ENVIRONMENTAL MONITORING, 2007, 9 (11): : 1176 - 1182