Brainstem Metabolites in Multiple System Atrophy of Cerebellar Type: 3.0-T Magnetic Resonance Spectroscopy Study

被引:13
|
作者
Takado, Yuhei [1 ,2 ]
Igarashi, Hironaka [1 ]
Terajima, Kenshi [1 ,2 ,3 ]
Shimohata, Takayoshi [2 ]
Ozawa, Tetsutaro [2 ]
Okamoto, Kouichirou [1 ,4 ]
Nishizawa, Masatoyo [1 ,2 ]
Nakada, Tsutomu [1 ]
机构
[1] Niigata Univ, Brain Res Inst, Ctr Integrated Human Brain Sci, Niigata 9518585, Japan
[2] Niigata Univ, Brain Res Inst, Dept Neurol, Niigata 9518585, Japan
[3] Univ Niigata Med & Dent Hosp, Dept Med Informat, Niigata, Japan
[4] Niigata Univ, Brain Res Inst, Dept Neurosurg, Niigata 9518585, Japan
关键词
MSA-C; MRS; UMSARS; myo-inositol; brainstem; biomarker; CONSENSUS STATEMENT; PHENOTYPE SPECTRUM; MR SPECTROSCOPY; H-1; MRS; DISEASE; CHOLINE; DIFFERENTIATION; MYOINOSITOL; DIAGNOSIS; LCMODEL;
D O I
10.1002/mds.23550
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The aim of this study was to find biomarkers of disease severity in multiple system atrophy of cerebellar type by imaging disease specific regions using proton magnetic resonance spectroscopy on a 3.0 T system. Methods: We performed proton magnetic resonance spectroscopy separately in the pons and medulla on 12 multiple system atrophy of cerebellar type patients and 12 age and gender matched control subjects. The metabolite concentrations were estimated from single-voxel proton magnetic resonance spectra measured by point resolved spectroscopy, which were then correlated with clinical severity using Part I, II, and IV of the unified multiple system atrophy rating scale. Results: Proton magnetic resonance spectroscopy showed that myo-inositol concentrations in both the pons and medulla were significantly higher in multiple system atrophy of cerebellar type patients compared to those of the control subjects (P < 0.05). By contrast, total N-acetylaspartate (the sum of N-acetylaspartate and N-acetylaspartylglutamate) and total choline compounds concentrations in both the pons and medulla were significantly lower in multiple system atrophy of cerebellar type patients compared to control subjects (P < 0.05). Creatine concentration in the pons was significantly higher in multiple system atrophy of cerebellar type patients compared to the control subjects (P < 0.05). Furthermore, a significant correlation was found between the myo-inositol/creatine ratio in the pons and clinical severity, defined by the sum score of unified multiple system atrophy rating scale (I+II+IV) (r = 0.76, P < 0.01). Conclusion: Proton magnetic resonance spectroscopy, in conjunction with a 3.0 T system, can be feasible to detect part of pathological changes in the brainstem, such as gliosis and neuronal cell loss, and the metabolites can be used as biomarkers of clinical severity in multiple system atrophy of cerebellar type patients. (C) 2011 Movement Disorder Society
引用
收藏
页码:1297 / 1302
页数:6
相关论文
共 50 条
  • [21] Clinical Features of Multiple System Atrophy, Cerebellar Type
    Lin, David J.
    Hermann, Katherine L.
    Schmahmann, Jeremy D.
    ANNALS OF NEUROLOGY, 2014, 76 : S43 - S44
  • [22] Phenylketonuria: white-matter changes assessed by 3.0-T magnetic resonance (MR) imaging, MR spectroscopy and MR diffusion
    Scarabino, T.
    Popolizio, T.
    Tosetti, M.
    Montanaro, D.
    Giannatempo, G. M.
    Terlizzi, R.
    Pollice, S.
    Maiorana, A.
    Maggialetti, N.
    Carriero, A.
    Leuzzi, V.
    Salvolini, U.
    RADIOLOGIA MEDICA, 2009, 114 (03): : 461 - 474
  • [23] 1.5-T and 3.0-T Magnetic Resonance Imaging Artifacts from Breast Biopsy Clips
    Le-Petross, H.
    Carkaci, S.
    Stafford, R.
    Elliott, A.
    Jackson, E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2007, 188 (05)
  • [24] The use of high resolution magnetic resonance on 3.0-T system in solid/multicystic ameloblastoma surgical planning Case report
    Cassetta, Michele
    Pranno, Nicola
    Di Carlo, Stefano
    Sorrentino, Valentina
    Stagnitti, Andrea
    Pompa, Giorgio
    ANNALI ITALIANI DI CHIRURGIA, 2014, 85 (03) : 219 - 224
  • [25] Unexpectedly Smaller Artifacts of 3.0-T Magnetic Resonance Imaging than 1.5 T: Recommendation of 3.0-T Scanners for Patients with Magnet-Resistant Adjustable Ventriculoperitoneal Shunt Devices
    Amano, Yuki
    Kuroda, Naoto
    Uchida, Daiki
    Sakakura, Yuya
    Nakatogawa, Hirokazu
    Ando, Naoto
    Nakayama, Teiji
    Sato, Haruhiko
    Masui, Takayuki
    Sameshima, Tetsuro
    Tanaka, Tokutaro
    WORLD NEUROSURGERY, 2019, 130 : E393 - E399
  • [26] Magnetic resonance spectroscopy of the canine brain at 3.0 T and 7.0 T
    Martin-Vaquero, Paula
    da Costa, Ronaldo C.
    Echandi, Rita L.
    Sammet, Christina L.
    Knopp, Michael V.
    Sammet, Steffen
    RESEARCH IN VETERINARY SCIENCE, 2012, 93 (01) : 427 - 429
  • [27] Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography
    Kim, So Yeon
    Byun, Jae Ho
    Hong, Hye-Suk
    Choi, Eugene K.
    Lee, Seung Soo
    Park, Seong Ho
    Lee, Moon-Gyu
    INVESTIGATIVE RADIOLOGY, 2008, 43 (08) : 594 - 602
  • [28] 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences
    Morakkabati-Spitz, N
    Gieseke, J
    Kuhl, C
    Lutterbey, G
    von Falkenhausen, M
    Traeber, F
    Zivanovic, O
    Schild, HH
    EUROPEAN RADIOLOGY, 2005, 15 (04) : 639 - 644
  • [29] Dynamic Contrast-Enhanced Magnetic Resonance Imaging for Pancreatic Ductal Adenocarcinoma at 3.0-T Magnetic Resonance: Correlation With Histopathology
    Liu, Kefu
    Xie, Ping
    Peng, Weijun
    Zhou, Zhengrong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (01) : 13 - 18
  • [30] 3.0-T high-field magnetic resonance imaging of the female pelvis: preliminary experiences
    N. Morakkabati-Spitz
    J. Gieseke
    C. Kuhl
    G. Lutterbey
    M. von Falkenhausen
    F. Traeber
    O. Zivanovic
    H. H. Schild
    European Radiology, 2005, 15 : 639 - 644