Induced current magnetic resonance-electrical impedance tomography

被引:25
|
作者
Özparlak, L [1 ]
Ider, YZ [1 ]
机构
[1] Bilkent Univ, Dept Elect & Elect Engn, TR-06533 Ankara, Turkey
关键词
electrical impedance tomography (EIT); MR-EIT; current density imaging (CDI); induced current MR-EIT;
D O I
10.1088/0967-3334/26/2/027
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Magnetic resonance-electrical impedance tomography (MR-EIT) is a conductivity imaging method based on injecting currents into the object. In this study, a new MR-EIT method, whereby currents are induced inside the object by using external coils, is proposed. This new method is called induced current magnetic resonance-electrical impedance tomography. In induced current MR-EIT surface electrodes are not used and thereby artifacts due to electrodes are eliminated. The reconstruction algorithm is based on the measurement of only one component of the secondary magnetic flux density. The algorithm is an iterative one, is 3D and is based on the solution of a linear matrix equation at each iteration. For the measurement of secondary magnetic flux density, a pulse sequence to be used in the MRI system is proposed. Numerical simulations are performed to test the algorithm for both noise-free and noisy cases. The singular value behavior of the matrix is monitored and it is observed that at least two current induction profiles improve the images significantly. It is shown that induced current MR-EIT can be used to reconstruct absolute conductivity images without the need for any additional peripheral voltage measurement.
引用
收藏
页码:S289 / S305
页数:17
相关论文
共 50 条
  • [41] Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)
    Goksu, Cihan
    Scheffler, Klaus
    Ehses, Philipp
    Hanson, Lars G.
    Thielscher, Axel
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 748 - 760
  • [42] Conductivity and current density image reconstruction using harmonic Bz algorithm in magnetic resonance electrical impedance tomography
    Oh, SH
    Lee, BI
    Woo, EJ
    Lee, SY
    Cho, MH
    Kwon, O
    Seo, JK
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (19): : 3101 - 3116
  • [43] Magnetic Resonance - Electrical Impedance Tomography (MR-EIT) Research at METU
    Eyuboglu, B. Murat
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3932 - 3935
  • [44] A Novel Conductivity Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Wang, Yuyu
    Wang, Huixian
    Yang, Wenhui
    Hu, Xiaolin
    Song, Tao
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 3976 - 3979
  • [45] Experimental Verification of Contrast Mechanism in Magnetic Resonance Electrical Impedance Tomography (MREIT)
    Kim, Young Tae
    Oh, Tong In
    Woo, Eung Je
    2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, : 4987 - 4990
  • [46] Image Reconstruction Based on the Anatomical Information for Magnetic Resonance Electrical Impedance Tomography
    Hao, Liling
    Xu, Lisheng
    Yang, Benqiang
    Li, Gang
    APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY JOURNAL, 2016, 31 (06): : 700 - 705
  • [47] A feasibility study of magnetic resonance driven electrical impedance tomography using a phantom
    Wan, Yuqing
    Negishi, Michiro
    Constable, R. Todd
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (06) : 623 - 644
  • [48] ON A NONLINEAR PARTIAL DIFFERENTIAL EQUATION ARISING IN MAGNETIC RESONANCE ELECTRICAL IMPEDANCE TOMOGRAPHY
    Kim, Sungwhan
    Kwon, Ohin
    Seo, Jin Keun
    Yoon, Jeong-Rock
    SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 2002, 34 (03) : 511 - 526
  • [49] A feasibility study of magnetic resonance electrical impedance tomography for prostate cancer detection
    Liu, Yang
    Zhang, Yingchun
    PHYSIOLOGICAL MEASUREMENT, 2014, 35 (04) : 567 - 581
  • [50] Electrical conductivity imaging of postmortem canine brains using magnetic resonance electrical impedance tomography
    Woo, Eung Je
    Kim, Hyung Joong
    Lee, Byung Il
    Kim, Young Tae
    Lee, Soo Yeol
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4146 - 4149