A novel graphene quantum dots/choline chloride/gold nanoparticles-modified carbon fiber microelectrode for sensitive and selective determination of dopamine in the presence of a high concentration of ascorbic acid

被引:8
|
作者
Yang, Lili [1 ]
Wang, Tingting [1 ]
Bao, Changhao [1 ]
Shi, Min [1 ]
Huang, Xianju [1 ]
Cheng, Han [1 ,2 ]
机构
[1] South Cent Univ Nationalities, Coll Pharm, Wuhan, Peoples R China
[2] South Cent Univ Nationalities, Natl Demonstrat Ctr Expt Ethnopharmacol Educ, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Choline chloride; Graphene quantum dots; Carbon fiber microelectrode; Dopamine; Ascorbic acid; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; URIC-ACID; ELECTRODE; CHOLINE; ACETYLCHOLINE; SENSOR; NANOCOMPOSITE; SEROTONIN; OXIDE;
D O I
10.1016/j.jelechem.2021.115512
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We prepared a three-layer composite of gold nanoparticles (AuNPs), choline (Ch) and graphene quantum dots (GQDs), and applied it to modify a carbon fiber microelectrode (CFME) by potentiostatic deposition to obtain a GQDs/Ch/AuNPs/CFME for high-sensitivity determination of dopamine (DA) without inference from ascorbic acid (AA). The surface morphology of electrodes was investigated by scanning electron microscopy. The electrochemical behavior of DA and AA at different modified electrodes was investigated by cyclic voltammetry and differential pulse voltammetry in Tris-HCl buffer (pH = 9.0). Owing to a synergistic effect, the GQDs/ Ch/AuNPs/CFME exhibited an obvious electrocatalytic effect on positively charged DA and a significant shielding effect on negatively charged AA. The influence of experimental variables (duration of modification, pH of the working solution, scan rate) was studied. Under optimum conditions, in the presence of AA (1.0 x 10-3 mol/L), the GQDs/Ch/AuNPs/CFME described a fine linear enhancement for DA oxidation in the concentration range 0.01-10.0 mu M with an estimated lower limit of detection of 1.616 nM and limit of quantification of 5.389 nM. The modified electrochemical sensor was applied for DA determination in the presence of high concentration of AA in mouse serum without separation steps and with good recovery.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Sensitive determination of ascorbic acid, dopamine and uric acid by glassy carbon electrodes modified with β-cyclodextrin and graphene oxide
    Guo, Qiwen
    Liu, Siyuan
    Men, Xinpeng
    Chen, Zhe
    Yao, Lei
    Wang, Geming
    Zhao, Hongyang
    Lin, Zhidong
    Wu, Qian
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2022, 33 (30) : 23566 - 23579
  • [22] Selective Determination of Epinephrine in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Graphene
    Li, Xia
    Chen, Meifeng
    Ma, Xinying
    ANALYTICAL SCIENCES, 2012, 28 (02) : 147 - 151
  • [23] Selective Determination of Epinephrine in the Presence of Ascorbic Acid Using a Glassy Carbon Electrode Modified with Graphene
    Xia Li
    Meifeng Chen
    Xinying Ma
    Analytical Sciences, 2012, 28 : 147 - 151
  • [24] Synthesis of carbon nanoparticle embedded graphene for sensitive and selective determination of dopamine and ascorbic acid in biological fluids
    Biswas, Sudip
    Das, Rashmita
    Basu, Malini
    Bandyopadhyay, Rajib
    Pramanik, Panchanan
    RSC ADVANCES, 2016, 6 (103): : 100723 - 100731
  • [25] Gold nanoparticles/ethylenediamine/carbon nanotube modified glassy carbon electrode as the voltammetric sensor for selective determination of rutin in the presence of ascorbic acid
    Yang, Suling
    Qu, Lingbo
    Li, Gang
    Yang, Ran
    Liu, Cuicui
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2010, 645 (02) : 115 - 122
  • [26] Selective and sensitive determination of uric acid in the presence of ascorbic acid and dopamine by PDDA functionalized graphene/graphite composite electrode
    Yu, Yanyan
    Chen, Zuanguang
    Zhang, Beibei
    Li, Xinchun
    Pan, Jianbin
    TALANTA, 2013, 112 : 31 - 36
  • [27] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Yan Wang
    Yan Xiao
    Microchimica Acta, 2012, 178 : 123 - 130
  • [28] Selective Determination of Dopamine in the Presence of Ascorbic Acid Using a Poly (Nicotinic Acid) Modified Carbon Paste Electrode
    Manjunatha, Jamballi G.
    Swamy, Bahaddurghatta E. Kumara
    Shreenivas, Mellekatte T.
    Mamatha, Ganjeenahalli P.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2012, 4 (03): : 225 - 237
  • [29] Glassy carbon electrode modified with poly(dibromofluorescein) for the selective determination of dopamine and uric acid in the presence of ascorbic acid
    Wang, Yan
    Xiao, Yan
    MICROCHIMICA ACTA, 2012, 178 (1-2) : 123 - 130
  • [30] Electrostatic repulsion strategy for high-sensitive and selective determination of dopamine in the presence of uric acid and ascorbic acid
    Wang, Ling
    Yang, Ran
    Qu, Lingbo
    Harrington, Peter de B.
    TALANTA, 2020, 210 (210)