A novel graphene quantum dots/choline chloride/gold nanoparticles-modified carbon fiber microelectrode for sensitive and selective determination of dopamine in the presence of a high concentration of ascorbic acid

被引:8
|
作者
Yang, Lili [1 ]
Wang, Tingting [1 ]
Bao, Changhao [1 ]
Shi, Min [1 ]
Huang, Xianju [1 ]
Cheng, Han [1 ,2 ]
机构
[1] South Cent Univ Nationalities, Coll Pharm, Wuhan, Peoples R China
[2] South Cent Univ Nationalities, Natl Demonstrat Ctr Expt Ethnopharmacol Educ, Wuhan 430074, Peoples R China
基金
中国国家自然科学基金;
关键词
Gold nanoparticles; Choline chloride; Graphene quantum dots; Carbon fiber microelectrode; Dopamine; Ascorbic acid; ELECTROCHEMICAL DETECTION; GOLD NANOPARTICLES; URIC-ACID; ELECTRODE; CHOLINE; ACETYLCHOLINE; SENSOR; NANOCOMPOSITE; SEROTONIN; OXIDE;
D O I
10.1016/j.jelechem.2021.115512
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We prepared a three-layer composite of gold nanoparticles (AuNPs), choline (Ch) and graphene quantum dots (GQDs), and applied it to modify a carbon fiber microelectrode (CFME) by potentiostatic deposition to obtain a GQDs/Ch/AuNPs/CFME for high-sensitivity determination of dopamine (DA) without inference from ascorbic acid (AA). The surface morphology of electrodes was investigated by scanning electron microscopy. The electrochemical behavior of DA and AA at different modified electrodes was investigated by cyclic voltammetry and differential pulse voltammetry in Tris-HCl buffer (pH = 9.0). Owing to a synergistic effect, the GQDs/ Ch/AuNPs/CFME exhibited an obvious electrocatalytic effect on positively charged DA and a significant shielding effect on negatively charged AA. The influence of experimental variables (duration of modification, pH of the working solution, scan rate) was studied. Under optimum conditions, in the presence of AA (1.0 x 10-3 mol/L), the GQDs/Ch/AuNPs/CFME described a fine linear enhancement for DA oxidation in the concentration range 0.01-10.0 mu M with an estimated lower limit of detection of 1.616 nM and limit of quantification of 5.389 nM. The modified electrochemical sensor was applied for DA determination in the presence of high concentration of AA in mouse serum without separation steps and with good recovery.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A novel nanoporous gold modified electrode for the selective determination of dopamine in the presence of ascorbic acid
    Qiu, Hua-Jun
    Zhou, Gui-Ping
    Ji, Guang-Lei
    Zhang, Yun
    Huang, Xi-Rong
    Ding, Yi
    COLLOIDS AND SURFACES B-BIOINTERFACES, 2009, 69 (01) : 105 - 108
  • [2] Determination of Dopamine Based on RO/Gold Nanoparticles-poly (dienedimethylammonium chloride) Modified Carbon Fiber Microelectrode
    Li Yuan
    Wang Tingting
    Li Mei
    Cheng Han
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2018, 39 (08): : 1656 - 1661
  • [3] Selective determination of dopamine in the presence of high concentration ascorbic acid and uric acid using carbon nanotube modified glassy carbon electrode
    Sun, YY
    Wu, KB
    Hu, SS
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2002, 23 (11): : 2067 - 2069
  • [4] Determination of Dopamine in the Presence of Ascorbic Acid by Nafion and Single-Walled Carbon Nanotube Film Modified on Carbon Fiber Microelectrode
    Jeong, Haesang
    Jeon, Seungwon
    SENSORS, 2008, 8 (11): : 6924 - 6935
  • [5] Selective determination of norepinephrine in the presence of high concentration of ascorbic acid with nano-gold modified glassy carbon electrodes
    Zhang, H
    Jin, BK
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 30 (11) : 1285 - 1288
  • [6] Simple and sensitive detection of dopamine in the presence of high concentration of ascorbic acid using gold nanoparticles as colorimetric probes
    Yuanfu Zhang
    Baoxin Li
    Xingling Chen
    Microchimica Acta, 2010, 168 : 107 - 113
  • [7] Simple and sensitive detection of dopamine in the presence of high concentration of ascorbic acid using gold nanoparticles as colorimetric probes
    Zhang, Yuanfu
    Li, Baoxin
    Chen, Xingling
    MICROCHIMICA ACTA, 2010, 168 (1-2) : 107 - 113
  • [8] Mesoporous Graphene-Modified Electrode for Independent and Selective Detection of Dopamine in the Presence of High Concentration of Ascorbic Acid
    Nankya, Rosalynn
    Opar, David O.
    Jung, Hyun
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2020, 41 (02) : 170 - 175
  • [9] Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2008, 53 (22) : 6610 - 6615
  • [10] Highly sensitive and selective detection of dopamine in the presence of ascorbic acid at graphene oxide modified electrode
    Gao, Feng
    Cai, Xili
    Wang, Xia
    Gao, Cai
    Liu, Shaoli
    Gao, Fei
    Wang, Qingxiang