In vitro circulation model driven by tissue-engineered dome-shaped cardiac tissue

被引:3
|
作者
Kikuchi, Tetsutaro [1 ]
Matsuura, Katsuhisa [1 ]
Shimizu, Tatsuya [1 ]
机构
[1] Tokyo Womens Med Univ TWIns, Inst Adv Biomed Engn & Sci, Shinjuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
关键词
cell sheet technology; induced pluripotent stem cell; cardiomyocyte; tissue engineering; organ on a chip; drug screening; CELL-DERIVED CARDIOMYOCYTES; RISK-ASSESSMENT; CONSTRUCTION; FABRICATION; MATURATION; PLATFORM; COLLAGEN;
D O I
10.1088/1758-5090/ac77c1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The heart is an essential organ for animals and humans. With the increased availability of pluripotent stem cells, the use of three-dimensional cardiac tissues consisting of cultured cardiomyocytes in in vitro drug evaluation has been widely studied. Several models have been proposed for the realization of the pump function, which is the original function of the heart. However, there are no models that simulate the human circulatory system using cultured cardiac tissue. This study shows that a dome-shaped cardiac tissue fabricated using the cell sheet stacking technique can achieve a heart-like pump function and circulate culture medium, there by mimicking the human circulatory system. Firstly, human induced pluripotent stem cells were differentiated into autonomously beating cardiomyocytes, and cardiomyocyte cell sheets were created using temperature-responsive culture dishes. A cardiomyocyte sheet and a human dermal fibroblast sheet were stacked using a cell sheet manipulator. This two-layered cell sheet was then inflated to create a dome-shaped cardiac tissue with a base diameter of 8 mm. The volume of the dome-shaped cardiac tissue changed according to the autonomous beating. The stroke volume increased with the culture period and reached 21 +/- 8.9 mu l (n = 6) on day 21. It also responded to beta-stimulant and extracellular calcium concentrations. Internal pressure fluctuations were also recorded under isovolumetric conditions by dedicated culture devices. The peak heights of pulsatile pressure were 0.33 +/- 0.048 mmHg (n = 3) under a basal pressure of 0.5 mmHg on day 19. When the tissue was connected to a flow path that had check valves applied, it drove a directional flow with an average flow rate of approximately 1 mu l s(-1). Furthermore, pressure-volume (P-V) diagrams were created from the simultaneous measurement of changes in pressure and volume under three conditions of fluidic resistance. In conclusion, this cardiac model can potentially be used for biological pumps that drive multi-organ chips and for more accurate in vitro drug evaluation using P-V diagrams.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Tissue-Engineered Heart Valve: Future of Cardiac Surgery
    Rippel, Radoslaw A.
    Ghanbari, Hossein
    Seifalian, Alexander M.
    WORLD JOURNAL OF SURGERY, 2012, 36 (07) : 1581 - 1591
  • [22] Hypothermic and cryogenic preservation of cardiac tissue-engineered constructs
    Janssen, Jasmijn
    Chirico, Nino
    Ainsworth, Madison J.
    Cedillo-Servin, Gerardo
    Viola, Martina
    Dokter, Inge
    Vermonden, Tina
    Doevendans, Pieter A.
    Serra, Margarida
    Voets, Ilja K.
    Malda, Jos
    Castilho, Miguel
    van Laake, Linda W.
    Sluijter, Joost P. G.
    Sampaio-Pinto, Vasco
    van Mil, Alain
    BIOMATERIALS SCIENCE, 2024, 12 (15) : 3866 - 3881
  • [23] In vitro study of bioactivity of homemade tissue-engineered periosteum
    Zhao, Lin
    Zhao, Junli
    Yu, Jiajia
    Zhao, Xiaofei
    Chen, Qi
    Huang, Yanfeng
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 58 : 1170 - 1176
  • [24] Towards a Tissue-Engineered Contractile Fontan-Conduit: The Fate of Cardiac Myocytes in the Subpulmonary Circulation
    Biermann, Daniel
    Eder, Alexandra
    Arndt, Florian
    Seoudy, Hatim
    Reichenspurner, Hermann
    Mir, Thomas
    Riso, Arlindo
    Kozlik-Feldmann, Rainer
    Peldschus, Kersten
    Kaul, Michael G.
    Schuler, Tillman
    Krasemann, Susanne
    Hansen, Arne
    Eschenhagen, Thomas
    Sachweh, Joerg S.
    PLOS ONE, 2016, 11 (11):
  • [25] TISSUE-ENGINEERED CARTILAGE REPAIR IN AN EXPERIMENTAL MODEL
    Robla Costales, D.
    Meana Infiesta, A.
    Alvarez Garcia, R.
    Robla Costales, J.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 17 - 18
  • [26] Construction and in vitro testing of a multilayered, tissue-engineered meniscus
    Bahcecioglu, Gokhan
    Buyuksungur, Arda
    Kiziltay, Aysel
    Hasirci, Nesrin
    Hasirci, Vasif
    JOURNAL OF BIOACTIVE AND COMPATIBLE POLYMERS, 2014, 29 (03) : 235 - 253
  • [27] Developing a tissue-engineered model of the human bronchiole
    Miller, Cheryl
    George, Steven
    Niklason, Laura
    JOURNAL OF TISSUE ENGINEERING AND REGENERATIVE MEDICINE, 2010, 4 (08) : 619 - 627
  • [28] Cardiac CT of Dome-shaped Pulmonary Valve Stenosis
    Parillo, Marco
    De Stefano, Domenico
    RADIOLOGY, 2024, 311 (02)
  • [29] A model of tissue-engineered ventral hernia repair
    Fann, SA
    Terracio, L
    Yan, WT
    Franchini, JL
    Yost, MJ
    JOURNAL OF INVESTIGATIVE SURGERY, 2006, 19 (03) : 193 - 205
  • [30] A tissue-engineered scale model of the heart ventricle
    Luke A. MacQueen
    Sean P. Sheehy
    Christophe O. Chantre
    John F. Zimmerman
    Francesco S. Pasqualini
    Xujie Liu
    Josue A. Goss
    Patrick H. Campbell
    Grant M. Gonzalez
    Sung-Jin Park
    Andrew K. Capulli
    John P. Ferrier
    T. Fettah Kosar
    L. Mahadevan
    William T. Pu
    Kevin Kit Parker
    Nature Biomedical Engineering, 2018, 2 : 930 - 941