In vitro circulation model driven by tissue-engineered dome-shaped cardiac tissue

被引:3
|
作者
Kikuchi, Tetsutaro [1 ]
Matsuura, Katsuhisa [1 ]
Shimizu, Tatsuya [1 ]
机构
[1] Tokyo Womens Med Univ TWIns, Inst Adv Biomed Engn & Sci, Shinjuku Ku, 8-1 Kawada Cho, Tokyo 1628666, Japan
关键词
cell sheet technology; induced pluripotent stem cell; cardiomyocyte; tissue engineering; organ on a chip; drug screening; CELL-DERIVED CARDIOMYOCYTES; RISK-ASSESSMENT; CONSTRUCTION; FABRICATION; MATURATION; PLATFORM; COLLAGEN;
D O I
10.1088/1758-5090/ac77c1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The heart is an essential organ for animals and humans. With the increased availability of pluripotent stem cells, the use of three-dimensional cardiac tissues consisting of cultured cardiomyocytes in in vitro drug evaluation has been widely studied. Several models have been proposed for the realization of the pump function, which is the original function of the heart. However, there are no models that simulate the human circulatory system using cultured cardiac tissue. This study shows that a dome-shaped cardiac tissue fabricated using the cell sheet stacking technique can achieve a heart-like pump function and circulate culture medium, there by mimicking the human circulatory system. Firstly, human induced pluripotent stem cells were differentiated into autonomously beating cardiomyocytes, and cardiomyocyte cell sheets were created using temperature-responsive culture dishes. A cardiomyocyte sheet and a human dermal fibroblast sheet were stacked using a cell sheet manipulator. This two-layered cell sheet was then inflated to create a dome-shaped cardiac tissue with a base diameter of 8 mm. The volume of the dome-shaped cardiac tissue changed according to the autonomous beating. The stroke volume increased with the culture period and reached 21 +/- 8.9 mu l (n = 6) on day 21. It also responded to beta-stimulant and extracellular calcium concentrations. Internal pressure fluctuations were also recorded under isovolumetric conditions by dedicated culture devices. The peak heights of pulsatile pressure were 0.33 +/- 0.048 mmHg (n = 3) under a basal pressure of 0.5 mmHg on day 19. When the tissue was connected to a flow path that had check valves applied, it drove a directional flow with an average flow rate of approximately 1 mu l s(-1). Furthermore, pressure-volume (P-V) diagrams were created from the simultaneous measurement of changes in pressure and volume under three conditions of fluidic resistance. In conclusion, this cardiac model can potentially be used for biological pumps that drive multi-organ chips and for more accurate in vitro drug evaluation using P-V diagrams.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] An in vitro tissue-engineered model for osteochondral repair
    Peretti G.M.
    Buragas M.
    Scotti C.
    Mangiavini L.
    Sosio C.
    Giancamillo A.
    Domeneghini C.
    Fraschini G.
    Sport Sciences for Health, 2006, 1 (4) : 153 - 157
  • [2] Experimental study on tissue-engineered vascular model in vitro
    Xia, WS
    Lu, KH
    Ai, YF
    Xiong, M
    Zhang, LX
    Shu, MG
    TISSUE ENGINEERING, 2006, 12 (04): : 1088 - 1088
  • [3] Tissue-Engineered Cardiac Constructs for Cardiac Repair
    Miyagawa, Shigeru
    Roth, Matthias
    Saito, Atsuhiro
    Sawa, Yoshiki
    Kostin, Sawa
    ANNALS OF THORACIC SURGERY, 2011, 91 (01): : 320 - 329
  • [4] Tissue-engineered valved conduits in the pulmonary circulation
    Stock, UA
    Nagashima, M
    Khalil, PN
    Nollert, GD
    Herden, T
    Sperling, JS
    Moran, A
    Lien, J
    Martin, DP
    Schoen, FJ
    Vacanti, JP
    Mayer, JE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (04): : 732 - 740
  • [5] Integration of Tissue-engineered Cartilage With Host Cartilage: An In Vitro Model
    Theodoropoulos, John S.
    De Croos, J. N. Amritha
    Park, Sam S.
    Pilliar, Robert
    Kandel, Rita A.
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (10) : 2785 - 2795
  • [6] In vitro neural injury model for optimization of tissue-engineered constructs
    Cullen, D. Kacy
    Stabenfeldt, Sarah E.
    Simon, Crystal M.
    Tate, Ciara C.
    LaPlaca, Michelle C.
    JOURNAL OF NEUROSCIENCE RESEARCH, 2007, 85 (16) : 3642 - 3651
  • [7] A tissue-engineered model of fetal distal lung tissue
    Mondrinos, M. J.
    Koutzaki, S.
    Lelkes, P. I.
    Finck, C. M.
    AMERICAN JOURNAL OF PHYSIOLOGY-LUNG CELLULAR AND MOLECULAR PHYSIOLOGY, 2007, 293 (03) : L639 - L650
  • [8] FORMATION OF TISSUE-ENGINEERED CONSTRUCT OF CARTILAGE IN VITRO
    Surguchenko, V. A.
    Ponomareva, A. S.
    Kirsanova, L. A.
    Bubentsova, G. N.
    Skaletskij, N. N.
    Sevastianov, V. I.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2013, 15 (03): : 66 - 72
  • [9] Tissue-engineered valved conduits in the pulmonary circulation - Discussion
    Carpentier, AF
    Stock
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2000, 119 (04): : 740 - 740
  • [10] Tissue-engineered flexible ear-shaped cartilage
    Xu, JW
    Johnson, TS
    Motarjem, PM
    Peretti, GM
    Randolph, MA
    Yaremchuk, MJ