Evaluation of a large-tonnage FRP cable anchor system: Anchorage design and full-scale experiment

被引:27
|
作者
Zhou, Jingyang [1 ]
Wang, Xin [1 ,2 ]
Peng, Zheqi [1 ]
Wu, Zhishen [1 ,2 ]
Zhu, Zhongguo [3 ]
机构
[1] Southeast Univ, Key Lab C&PC Struct, Minist Educ, Nanjing 210096, Peoples R China
[2] Southeast Univ, Natl & Local Unified Engn Res Ctr Basalt Fiber Pr, Int Inst Urban Syst Engn, Nanjing 210096, Peoples R China
[3] Jiangsu Green Mat Valley New Mat T&D Co Ltd, Composites Div, Nanjing 210019, Peoples R China
关键词
Fiber-reinforced polymer (FRP); Cable; Load transfer component (LTC); Anchorage design; Finite element (FE) analysis; Full-scale experiment; REINFORCED POLYMER TENDONS; FIBER; PERFORMANCE; BEHAVIOR;
D O I
10.1016/j.engstruct.2021.113551
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to anisotropy of fiber-reinforced polymer (FRP) material, the anchoring of large-tonnage multiple-tendon FRP cable is a challenge. To solve this problem, a large-tonnage FRP cable anchor system (CAS) was designed numerically by optimizing five key anchorage parameters affecting the anchor efficiency and implemented in three full-scale basalt FRP (BFRP) cables with 37 Phi 7 tendons. The numerical results showed that the cable radial displacement increases with the spacing of tendons increasing. The cable radial compressive stress and displacement decrease with the thickness of the load transfer component (LTC) increasing. Increasing anchor length and conical angle have significant reducing effect on the cable axial displacement but a negligible effect on the cable radial displacement. Experimental verification showed that the mean anchor efficiency and ultimate load of the BFRP cables were 95% and 1919 kN, respectively. The maximum axial strain difference of the BFRP cable at the loading and free ends increased with the load. The shear stress of the center BFRP tendon first increased rapidly, then decreased slowly, then increased gradually again, and finally decreased quickly. The axial strains and shear stress of the BFRP cable in the anchor zone were consistent with the FE results, and were proved to follow linear and cubic functions, respectively.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] USING LABORATORY DATA TO DESIGN A FULL-SCALE TREATMENT SYSTEM
    NYER, EK
    GROUND WATER MONITORING AND REMEDIATION, 1992, 12 (01): : 85 - 87
  • [32] Appropriate evaluation of HIV prevention interventions: from experiment to full-scale implementation
    Hallett, Timothy B.
    White, Peter J.
    Garnett, Geoff P.
    SEXUALLY TRANSMITTED INFECTIONS, 2007, 83 : I55 - I60
  • [33] Experimental Evaluation of a Full-Scale HVAC System Working with Nanofluid
    Milanese, Marco
    Micali, Francesco
    Colangelo, Gianpiero
    de Risi, Arturo
    ENERGIES, 2022, 15 (08)
  • [34] Full-scale field evaluation of wireless MEMS monitoring system
    Kim, Hongjin
    Kim, Whajung
    Kim, Boung-Yong
    Cho, Bong-Ho
    SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2008, PTS 1 AND 2, 2008, 6932
  • [35] Synthesis of Optimal Structure of UAV Stabilization System by Full-Scale Experiment Data
    Krivonosenko, O. P.
    Savchenko, O. V.
    2015 IEEE 3RD INTERNATIONAL CONFERENCE ACTUAL PROBLEMS OF UNMANNED AERIAL VEHICLES DEVELOPMENTS (APUAVD), 2015, : 112 - 115
  • [36] Full-scale model test of pre-stressed cable-pylon anchorage for single-oblique-pylon cable-stayed bridges
    Ye, Huawen
    Li, Cuijuan
    Xu, Xun
    Xiao, Lin
    Qiang, Shizhong
    Xinan Jiaotong Daxue Xuebao/Journal of Southwest Jiaotong University, 2014, 49 (01): : 52 - 58
  • [37] Fatigue Design Evaluation of Railway Bogie with Full-Scale Fatigue Test
    Seo, Jung-Won
    Hur, Hyun-Moo
    Jun, Hyun-Kyu
    Kwon, Seok-Jin
    Lee, Dong-Hyeong
    ADVANCES IN MATERIALS SCIENCE AND ENGINEERING, 2017, 2017
  • [38] Full-scale Segment Model Test and Stress Analysis of Abnormally Shaped Anchorage Zone of Cable-stayed Bridge Pylon
    Li Yue
    Cai Qinfeng
    TRENDS IN CIVIL ENGINEERING, PTS 1-4, 2012, 446-449 : 1148 - +
  • [39] Full-Scale Experiment Bridge WILD - Design of an UHPC Arch Bridge based on Experiments
    Freytag, Bernhard
    Reichel, Michael
    Sparowitz, Lutz
    Santner, Gerhard
    Heinzle, Guenter
    BETON- UND STAHLBETONBAU, 2009, 104 (03) : 134 - 144
  • [40] Evaluation of aerodynamic damping in full-scale rain-wind-induced stay cable vibration
    Hua, Jieying
    Zuo, Delong
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2019, 191 : 215 - 226