Improved arthroscopic one-piece excision technique for the treatment of symptomatic discoid medial meniscus

被引:2
|
作者
Wang, Hong-De [1 ,2 ]
Li, Tong [1 ]
Gao, Shi-Jun [1 ,2 ]
机构
[1] Hebei Med Univ, Hosp 3, Dept Orthoped, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
[2] Orthopaed Biomech Lab Hebei Prov, 139 Ziqiang Rd, Shijiazhuang 050051, Hebei, Peoples R China
关键词
Discoid medial meniscus; Improved one-piece excision; Technique; TERM-FOLLOW-UP; LATERAL MENISCUS; CONSERVATIVE TREATMENT; CHILDREN; MENISCECTOMY;
D O I
10.1186/s13018-017-0661-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Discoid medial meniscus is an extremely rare abnormality of the knee. During arthroscopic meniscectomy for symptomatic discoid medial meniscus, it is difficult to remove the posterior portion of the meniscus because of the confined working space within the compartment and the obstruction caused by the anterior cruciate ligament and the tibial intercondylar eminence. To overcome these problems, we describe an improved arthroscopic technique for one-piece excision of symptomatic discoid medial meniscus through three unique portals. Methods: Three improved portals were made in the injured knee: a standard anteromedial portal, a central transpatellar tendon portal, and a high anterolateral portal. The anterior side of the discoid medial meniscus was cut 7 mm from the periphery of the meniscus. Next, the anterior portion of the free discoid meniscus fragment was pulled in the anterolateral direction with tension. A curve-shaped cut was made along the longitudinal tear to the posterior horn using basket forceps through the standard anteromedial portal. Then, the anterior portion of the free discoid meniscus was pulled in the anteromedial direction. Pulling the fragment under tension made it easier to cut the posterior side of the discoid meniscus. The posterior side of the discoid meniscus was cut 7 mm from the periphery of the meniscus with straight scissors or basket forceps through the central transpatellar tendon portal. Results: This technique resulted in satisfactory results. Excellent visualization of the posterior part of the discoid medial meniscus was gained during the procedure, and it was easy to cut the posterior part of the discoid medial meniscus. No recurrent symptoms were found. Conclusions: This improved arthroscopic one-piece excision technique for the treatment of symptomatic discoid medial meniscus enables the posterior part of the meniscus to be cut satisfactorily. Moreover, compared with previous techniques, this novel technique causes less formation of foreign bodies and less damage to the anterior cruciate ligament, medial collateral ligament, and cartilage and requires a shorter procedural time.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Horizontal cleavage tear of discoid medial meniscus diagnosed on MRI and treated with arthroscopic partial resection
    Michael H. Elvey
    Sujith Konan
    Charles V. House
    Rahul V. Patel
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1860 - 1867
  • [42] Intraocular Lens Explantation Technique for One-piece Acrylic Lenses
    Henderson, Bonnie A.
    Yang, E. Bo
    JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (07) : 499 - 502
  • [43] FABRICATING OXLEY BIRHOMB PRISMS - A TECHNIQUE FOR ONE-PIECE CONSTRUCTION
    SECKOLD, JA
    APPLIED OPTICS, 1985, 24 (12) : 1720 - 1721
  • [44] The size and diameter of pieces of cartilage are not fixed for the palisade technique and one-piece technique
    Zhu, Yanshuang
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (02) : 621 - 622
  • [45] A Reverse Suture Anchor Technique for Arthroscopic Medial Meniscus Root Repair
    Meng, Chen-yang
    Feng, Wei
    Ren, Yi-zhong
    Liu, Ming
    Wang, Jun-yi
    Han, Chang-xu
    ARTHROSCOPY TECHNIQUES, 2024, 13 (06):
  • [46] The size and diameter of pieces of cartilage are not fixed for the palisade technique and one-piece technique
    Yanshuang Zhu
    European Archives of Oto-Rhino-Laryngology, 2021, 278 : 621 - 622
  • [47] Arthroscopic treatment of symptomatic type D medial plica
    Uysal, Mustafa
    Asik, Mehmet
    Akpinar, Sercan
    Ciftci, Feyyaz
    Cesur, Necip
    Tandogan, Reha N.
    INTERNATIONAL ORTHOPAEDICS, 2008, 32 (06) : 799 - 804
  • [48] Arthroscopic treatment of symptomatic type D medial plica
    Mustafa Uysal
    Mehmet Asik
    Sercan Akpinar
    Feyyaz Ciftci
    Necip Cesur
    Reha N. Tandogan
    International Orthopaedics, 2008, 32 : 799 - 804
  • [49] Arthroscopic Medial Meniscus Posterior Root Reconstruction and Pull-Out Repair Combined Technique for Root Tear of Medial Meniscus
    Ishikawa, Hiroki
    Okamura, Hiroki
    Ohno, Takuya
    Fujita, Shogo
    Akezuma, Hirotaka
    Inagaki, Katsunori
    ARTHROSCOPY TECHNIQUES, 2022, 11 (02): : E109 - E114
  • [50] Magnetic Resonance Imaging Findings in Symptomatic Patients After Arthroscopic Partial Meniscectomy for Torn Discoid Lateral Meniscus
    Lee, Chang-Rack
    Bin, Seong-Il
    Kim, Jong-Min
    Kim, Nam-Ki
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (11): : 2366 - 2372