Pulmonary nodules: dosimetric and clinical studies at low dose multidetector CT

被引:0
|
作者
Hetmaniak, Y
Bard, JJ
Albuisson, E
Courthaliac, C
Reynier, C
Lhoste-Trouilloud, A
Crost, E
Petitcolin, V
Caillaud, D
Michel, JL
机构
[1] CHU Gabriel Monpied, Serv Radiol A, Clermont Ferrand, France
[2] Ctr Jean Perrin Radiotherapie, Clermont Ferrand, France
[3] Fac Med Clermont Ferrand, Serv Biostat & Informat Med, Clermont Ferrand, France
[4] CHU Gabriel Monpied, Serv Pneumol, Clermont Ferrand, France
来源
JOURNAL DE RADIOLOGIE | 2003年 / 84卷 / 04期
关键词
chest; multidetector CT; low dose; dosimetry; screening; lung; nodule;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose. To measure breast radiation dose from multidetector CT using three different low dose protocols and compare it to a standard two view chest examination. To compare the number of pulmonary nodules detected at low and standard dose. Materials and methods. Thermoluminescent dosimetry was used to measure the absorbed dose on a phantom (Rando) and 10 patients. Then, we compared the standard dose to the low dose examinations. The Wilcoxon rank test and the kappa test were used to assess differences in the detection of nodules. Results. The absorbed dose of these low dose protocols correspond to the radiation dose for the acquisition of two to ten chest radiographs (two views). This study suggests that only the 30 mA protocol is sufficient for the detection of all pulmonary nodules; nodules smaller than 5 mm were overlooked at 10 mA. Conclusion. A good image quality can be obtained with low dose protocols at multidetector CT (correspond to 2 to 10 chest radiographs).
引用
收藏
页码:399 / 404
页数:6
相关论文
共 50 条
  • [31] Detection of pulmonary nodules with scoutless fixed-dose ultra-low-dose CT: a prospective study
    Gheysens, Gerald
    De Wever, Walter
    Cockmartin, Lesley
    Bosmans, Hilde
    Coudyzer, Walter
    De Vuysere, Sofie
    Lefere, Mathieu
    EUROPEAN RADIOLOGY, 2022, 32 (07) : 4437 - 4445
  • [32] Application effect of low-dose spiral CT on pulmonary nodules and its diagnostic value for benign and malignant nodules
    Zheng, Chengquan
    Wang, Haofeng
    Liu, Qiaozheng
    Han, Dong
    Xin, Yufei
    Lu, Weina
    Yan, Zhenchong
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (01): : 256 - 263
  • [33] Radiomics analysis of pulmonary nodules in low-dose CT for early detection of lung cancer
    Choi, Wookjin
    Oh, Jung Hun
    Riyahi, Sadegh
    Liu, Chia-Ju
    Jiang, Feng
    Chen, Wengen
    White, Charles
    Rimner, Andreas
    Mechalakos, James G.
    Deasy, Joseph O.
    Lu, Wei
    MEDICAL PHYSICS, 2018, 45 (04) : 1537 - 1549
  • [34] Automated detection of pulmonary nodules from low dose helical CT scans: Work in progress
    Asmamaw, A
    Reeves, AP
    Stein, BG
    Yankelevitz, DF
    Henschke, CI
    RADIOLOGY, 2002, 225 : 477 - 477
  • [35] Low dose helical multidetector chest CT in routine practice
    Tack, DM
    Bailly, J
    Muller, P
    Alkeilani, O
    Nicaise, N
    Delcour, CP
    RADIOLOGY, 2000, 217 : 383 - 383
  • [36] Volume quantitation of small pulmonary nodules on low-dose chest CT: A phantom study
    Ko, JP
    Rusinek, H
    Chandra, R
    McGuinness, G
    Betke, M
    Naidich, DP
    RADIOLOGY, 2001, 221 : 312 - 312
  • [37] Can dynamic contrast enhanced multidetector CT differentiate the nature of different pulmonary nodules?
    Fouda, Nehad
    Helmy, Eman M.
    Fattah, Sherif Abdel
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2018, 49 (03): : 631 - 637
  • [38] Clinical importance of small pulmonary nodules detected at CT
    Wysoki, MG
    RADIOLOGY, 1997, 204 (02) : 583 - 583
  • [39] DOSIMETRIC ASPECTS OF A NEW LOW-DOSE CT SCANNER
    KATZEN, MJ
    MAHESHUARI, PN
    MEDICAL PHYSICS, 1981, 8 (01) : 137 - 137
  • [40] Deep Learning for Malignancy Risk Estimation of Pulmonary Nodules Detected at Low-Dose Screening CT
    Venkadesh, Kiran Vaidhya
    Setio, Arnaud A. A.
    Schreuder, Anton
    Scholten, Ernst T.
    Chung, Kaman
    Wille, Mathilde M. W.
    Saghir, Zaigham
    van Ginneken, Bram
    Prokop, Mathias
    Jacobs, Colin
    RADIOLOGY, 2021, 300 (02) : 438 - 447