Ex Vivo Evaluation of Mouse Brain Elasticity Using High-Frequency Ultrasound Elastography

被引:16
|
作者
Lay, Fang-Yi [1 ]
Chen, Pei-Yu [1 ]
Cheng, Hsiang-Fan [2 ]
Kuo, Yu-Min [2 ,3 ]
Huang, Chih-Chung [1 ,4 ]
机构
[1] Natl Cheng Kung Univ, Coll Engn, Dept Biomed Engn, Tainan 701, Taiwan
[2] Natl Cheng Kung Univ, Coll Med, Inst Basic Med Sci, Tainan, Taiwan
[3] Natl Cheng Kung Univ, Coll Med, Dept Cell Biol & Anat, Tainan, Taiwan
[4] Natl Cheng Kung Univ, Med Device Innovat Ctr, Tainan 701, Taiwan
关键词
Brain elasticity; high-frequency ultrasound; elastography; shear wave imaging; small-animal imaging; MAGNETIC-RESONANCE ELASTOGRAPHY; IN-VIVO; TRANSIENT ELASTOGRAPHY; VISCOELASTIC PROPERTIES; TISSUE ELASTICITY; MR ELASTOGRAPHY; STIFFNESS; PARAMETERS; INJURY;
D O I
10.1109/TBME.2019.2905551
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Most neurodegenerative diseases are highly linked with aging. The mechanical properties of the brain should be determined for predicting and diagnosing age-related brain diseases. A preclinical animal study is crucial for neurological disease research. However, estimation of the elasticity properties of different regions of mouse brains remains difficult because of the size of the brain. In this paper, high-frequency ultrasound elastography (HFUSE) based on shear wave imaging was proposed for mapping the stiffness of the mouse brain at different ages ex vivo. Methods: For HFUSE, a 40-MHz ultrasound array transducer with an ultrafast ultrasound imaging system was used in this paper. The accuracy and resolution during HFUSE were determined through a mechanical testing system and by conducting phantom experiments. Results: In the experiments, the error in the elastic modulus measurement was approximately 10% on average, and the axial resolution was 248 mu m. Animal testing was conducted using mice that were 4 (young aged) and 11 (middle aged) months old. The elasticity distributions of the cortex and hippocampus in the mouse brains were obtained through HFUSE. Conclusion: The average shear moduli of the cortex and hippocampus were 3.84 and 2.33 kPa for the 4-month-old mice and 3.77 and 1.94 kPa for the 11-month-old mice, respectively. No statistical difference was observed in the cortex stiffness of mice of different ages. However, the hippocampus significantly softened with aging.
引用
收藏
页码:3426 / 3435
页数:10
相关论文
共 50 条
  • [31] Evaluation of Hand Tendon Elastic Properties During Rehabilitation Through High-Frequency Ultrasound Shear Elastography
    Chen, Pei-Yu
    Yang, Tai-Hua
    Kuo, Li-Chieh
    Hsu, Hsiu-Yun
    Su, Fong-Chin
    Huang, Chih-Chung
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (08) : 2716 - 2726
  • [32] Is My Mouse Pregnant? High-Frequency Ultrasound Assessment
    Phoon, Colin K. L.
    Ren, Mindong
    [J]. JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2021, (169):
  • [33] EVALUATION OF MYOCARDIAL MICROVASCULATURE BY HIGH-FREQUENCY ULTRASOUND
    CHANDRARATNA, PAN
    KHAN, M
    CHANDRASOMA, P
    JONES, JP
    GALLET, J
    [J]. CIRCULATION, 1992, 86 (04) : 575 - 575
  • [34] High-Frequency Ultrasound for Evaluation of Intimal Thickness
    Mohler, Emile R., III
    Sibley, Alexandra A.
    Schultz, Susan M.
    Zhang, Lifeng
    Sehgal, Chandra M.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (10) : 1129 - 1133
  • [35] Ultrasound elastography evaluation of age-related muscle atrophy: An ex vivo study
    Musa, Bushira
    An, Justin
    Mahmoud, Wagdy
    Denis, Max
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2023, 153 (03):
  • [36] Evaluation of postoperative complications of hypospadias using high-frequency ultrasound imaging
    Zhuang, Jun
    Su, Xueshang
    Jia, Ying
    Zheng, Qiaoyuan
    Wei, Qingqian
    Zhang, Ziming
    Hu, Jintian
    Yuan, Li
    Chai, Hongli
    [J]. BMC UROLOGY, 2024, 24 (01):
  • [37] In Vivo Measurement of Brain Tumor Elasticity Using Intraoperative Shear Wave Elastography
    Chauvet, D.
    Imbault, M.
    Capelle, L.
    Demene, C.
    Mossad, M.
    Karachi, C.
    Boch, A. -L.
    Gennisson, J. -L.
    Tanter, M.
    [J]. ULTRASCHALL IN DER MEDIZIN, 2016, 37 (06): : 584 - 590
  • [38] The use of high-frequency ultrasound imaging and biofluorescence for in vivo evaluation of gene therapy vectors
    Ingram, Nicola
    Macnab, Stuart A.
    Marston, Gemma
    Scott, Nigel
    Carr, Ian M.
    Markham, Alexander F.
    Whitehouse, Adrian
    Coletta, P. Louise
    [J]. BMC MEDICAL IMAGING, 2013, 13
  • [39] IN VIVO HIGH-FREQUENCY ULTRASOUND FOR THE CHARACTERIZATION OF THROMBI ASSOCIATED WITH AORTIC ANEURYSMS IN AN EXPERIMENTAL MOUSE MODEL
    Jansen, Christian H. P.
    Brangsch, Julia
    Reimann, Carolin
    Adams, Lisa
    Hamm, Bernd
    Botnar, Rene M.
    Makowski, Marcus R.
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (12): : 2882 - 2890
  • [40] INVIVO INVESTIGATIONS OF THE SKIN, ITS STRUCTURE AND ELASTICITY WITH HIGH-FREQUENCY ULTRASOUND
    BREITBART, EW
    HICKS, R
    GROVE, G
    [J]. JOURNAL OF INVESTIGATIVE DERMATOLOGY, 1986, 87 (01) : 131 - 131