TESTING THE APODIZED PUPIL LYOT CORONAGRAPH ON THE LABORATORY FOR ADAPTIVE OPTICS EXTREME ADAPTIVE OPTICS TESTBED

被引:8
|
作者
Thomas, Sandrine J. [1 ]
Soummer, Remi [2 ,5 ]
Dillon, Daren [1 ]
Macintosh, Bruce [3 ,5 ]
Gavel, Donald [1 ]
Sivaramakrishnan, Anand [4 ,5 ,6 ]
机构
[1] Univ Calif Santa Cruz, Lab Adapt Opt, Univ Calif Lick Observ, Santa Cruz, CA 95064 USA
[2] Space Telescope Sci Inst, Baltimore, MD 21218 USA
[3] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[4] Amer Museum Nat Hist, Dept Astrophys, New York, NY 10024 USA
[5] Univ Calif Santa Cruz, NSF Ctr Adapt Opt, Santa Cruz, CA 95064 USA
[6] SUNY Stony Brook, Stony Brook, NY 11790 USA
来源
ASTRONOMICAL JOURNAL | 2011年 / 142卷 / 04期
基金
美国国家科学基金会;
关键词
instrumentation: adaptive optics; instrumentation: high angular resolution; methods: laboratory; techniques: high angular resolution; SPHEROIDAL WAVE-FUNCTIONS; CLOSED-LOOP; DESIGN; ABERRATIONS;
D O I
10.1088/0004-6256/142/4/119
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We present testbed results of the Apodized Pupil Lyot Coronagraph (APLC) at the Laboratory for Adaptive Optics (LAO). These results are part of the validation and tests of the coronagraph and of the Extreme Adaptive Optics (ExAO) for the Gemini Planet Imager (GPI). The apodizer component is manufactured with a halftone technique using black chrome microdots on glass. Testing this APLC (like any other coronagraph) requires extremely good wavefront correction, which is obtained to the 1 nm rms level using the microelectricalmechanical systems (MEMS) technology, on the ExAO visible testbed of the LAO at the University of Santa Cruz. We used an APLC coronagraph without central obstruction, both with a reference super-polished flat mirror and with the MEMS to obtain one of the first images of a dark zone in a coronagraphic image with classical adaptive optics using a MEMS deformable mirror (without involving dark hole algorithms). This was done as a complementary test to the GPI coronagraph testbed at American Museum of Natural History, which studied the coronagraph itself without wavefront correction. Because we needed a full aperture, the coronagraph design is very different from the GPI design. We also tested a coronagraph with central obstruction similar to that of GPI. We investigated the performance of the APLC coronagraph and more particularly the effect of the apodizer profile accuracy on the contrast. Finally, we compared the resulting contrast to predictions made with a wavefront propagation model of the testbed to understand the effects of phase and amplitude errors on the final contrast.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Analysis and mitigation of pupil discontinuities on adaptive optics performance
    Schwartz, Noah
    Sauvage, Jean-Francois
    Correia, Carlos
    Neichel, Benoit
    Fusco, Thierry
    Quiros-Pacheco, Fernando
    Dohlen, Kjetil
    El Hadi, Kacem
    Agapito, Guido
    Thatte, Niranjan
    Clarke, Fraser
    [J]. ADAPTIVE OPTICS SYSTEMS VI, 2018, 10703
  • [42] Prototype-testbed for infrared optics and coronagraph (PINOCO)
    Enya, K.
    Haze, K.
    Arimatsu, K.
    Kataza, H.
    Wada, T.
    Kotani, T.
    Abe, L.
    Yamamuro, T.
    [J]. SPACE TELESCOPES AND INSTRUMENTATION 2012: OPTICAL, INFRARED, AND MILLIMETER WAVE, 2012, 8442
  • [43] Coronagraph design for an extreme adaptive optics system with spatially-filtered wavefront sensing on segmented telescopes
    Sivaramakrishnan, A
    Makidon, RB
    Soummer, R
    Macintosh, BA
    Troy, M
    Chanan, GA
    Lloyd, JP
    Perrin, MD
    Graham, JR
    Poyneer, L
    Sheinis, A
    [J]. ADVANCEMENTS IN ADAPTIVE OPTICS, PTS 1-3, 2004, 5490 : 535 - 544
  • [44] Sparse Calibration of an Extreme Adaptive Optics System
    Chiuso, Alessandro
    Muradore, Riccardo
    Aller-Carpentier, Emmanuel
    [J]. 49TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2010, : 1159 - 1164
  • [45] Science camera calibration for extreme adaptive optics
    Wallace, JK
    Green, JJ
    Shao, M
    Troy, M
    Lloyd, J
    MacIntosh, B
    [J]. ADVANCEMENTS IN ADAPTIVE OPTICS, PTS 1-3, 2004, 5490 : 370 - 378
  • [46] Extreme adaptive optics for the thirty meter telescope
    Macintosh, Bruce
    Troy, Mitchell
    Doyon, Rene
    Graham, James
    Baker, Kevin
    Bauman, Brian
    Marois, Christian
    Palmer, David
    Phillion, Donald
    Poyneer, Lisa
    Crossfield, Ian
    Dumont, Philip
    Levine, B. Marty
    Shao, Michael
    Serabyn, Gene
    Shelton, Chris
    Vasisht, Gautum
    Wallace, James K.
    Lavigne, Jean-Francois
    Valee, Philippe
    Rowlands, Neil
    Tam, Ken
    Hackett, Daniel
    [J]. ADVANCES IN ADAPTIVE OPTICS II, PRS 1-3, 2006, 6272 : U219 - U233
  • [47] Simulations of the extreme adaptive optics system for EPICS
    Korkiakoski, Visa
    Verinaud, Christophe
    [J]. ADAPTIVE OPTICS SYSTEMS II, 2010, 7736
  • [48] Extreme adaptive optics planet imager: XAOPI
    Macintosh, B
    Graham, J
    Poyneer, L
    Sommargren, G
    Wilhelmsen, J
    Gavel, D
    Jones, S
    Kalas, P
    Lloyd, J
    Makidon, R
    Olivier, S
    Palmer, D
    Patience, J
    Perrin, M
    Severson, S
    Shein, A
    Sivaramakrishnan, A
    Troy, M
    Wallace, K
    [J]. TECHNIQUES AND INSTRUMENTATION FOR DETECTION OF EXOPLANETS, 2003, 5170 : 272 - 282
  • [49] Adaptive optics; Principles, performance and challenges - Adaptive optics
    Devaney, N
    [J]. OPTICS IN ASTROPHYSICS, 2005, 198 : 181 - 206
  • [50] OSCA, an Optimised Stellar Coronagraph for Adaptive Optics: Description and first light
    Thompson, S
    Doel, P
    Bingham, R
    Charalambous, A
    Bissonauth, N
    Clark, P
    Myers, R
    Talbot, G
    [J]. ADAPTIVE OPTICAL SYSTEM TECHNOLOGIES II, PTS 1 AND 2, 2003, 4839 : 1085 - 1092