The relationships between personal PM exposures for elderly populations and indoor and outdoor concentrations for three retirement center scenarios

被引:55
|
作者
Rodes, CE [1 ]
Lawless, PA [1 ]
Evans, GF [1 ]
Sheldon, LS [1 ]
Williams, RW [1 ]
Vette, AF [1 ]
Creason, JP [1 ]
Walsh, D [1 ]
机构
[1] Res Triangle Inst, Res Triangle Pk, NC 27709 USA
关键词
elderly; indoor; particulate matter; personal exposure; outdoor;
D O I
10.1038/sj.jea.7500155
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Personal exposures, indoor and outdoor concentrations, and questionnaire data were collected in three retirement center settings, supporting broader particulate matter (PM) -health studies of elderly populations. The studies varied geographically and temporally, with populations studied in Baltimore, MD in the summer of 1998, and Fresno, CA in the winter and spring of 1999. The sequential nature of the studies and the relatively rapid review of the mass concentration data after each segment provided the opportunity to modify the experimental designs, including the information collected from activity diary and baseline questionnaires and influencing factors (e.g., heating, ventilation, and air-conditioning (HVAC) system operation, door and window openings, air exchange rate) measurements. This paper highlights both PM2.5 and PM10 personal exposure data and interrelationships across the three retirement center settings, and identifies the most probable influencing factors. The current limited availability of questionnaire results, and chemical speciation data beyond mass concentration for these studies, provided only limited capability to estimate personal exposures from models and apportion the personal exposure collections to their sources. The mean personal PM2.5 exposures for the elderly in three retirement centers were found to be consistently higher than the paired apartment concentrations by 50% to 68%, even though different facility types and geographic locations were represented. Mean personal - to - outdoor ratios were found to 0.70, 0.82, and 1.10, and appeared to be influenced by the time doors and windows were open and aggressive particle removal by the HVAC systems. Essentially identical computed mean PM2.5 personal clouds of 3 mug/m(3) were determined for two of the studies. The proposed significant contributing factors to these personal clouds were resuspended particles from carpeting, collection of body dander and clothing fibers, personal proximity to open doors and windows, and elevated PM levels in nonapartment indoor microenvironments.
引用
下载
收藏
页码:103 / 115
页数:13
相关论文
共 50 条
  • [31] Influence of ambient (outdoor) sources on residential indoor and personal PM2.5 concentrations: Analyses of RIOPA data
    Qing Yu Meng
    Barbara J Turpin
    Leo Korn
    Clifford P Weisel
    Maria Morandi
    Steven Colome
    Junfeng Zhang
    Thomas Stock
    Dalia Spektor
    Arthur Winer
    Lin Zhang
    Jong Hoon Lee
    Robert Giovanetti
    William Cui
    Jaymin Kwon
    Shahnaz Alimokhtari
    Derek Shendell
    Jennifer Jones
    Corice Farrar
    Silvia Maberti
    Journal of Exposure Science & Environmental Epidemiology, 2005, 15 : 17 - 28
  • [32] Correlations between short-term indoor and outdoor PM concentrations at residences with evaporative coolers
    Li, WW
    Paschold, H
    Morales, H
    Chianelli, J
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (19) : 2691 - 2703
  • [33] Indoor/Outdoor Relationships between PM10 and Associated Organic Compounds in a Primary School
    Alves, Celia A.
    Urban, Roberta C.
    Pegas, Priscilla N.
    Nunes, Teresa
    AEROSOL AND AIR QUALITY RESEARCH, 2014, 14 (01) : 86 - 98
  • [34] Estimating Error in Using Residential Outdoor PM2.5 Concentrations as Proxies for Personal Exposures: A Meta-analysis
    Avery, Christy L.
    Mills, Katherine T.
    Williams, Ronald
    McGraw, Kathleen A.
    Poole, Charles
    Smith, Richard L.
    Whitsel, Eric A.
    ENVIRONMENTAL HEALTH PERSPECTIVES, 2010, 118 (05) : 673 - 678
  • [35] Personal Exposure of 80 Retired Elders and Their Residential Indoor, Outdoor PM10 Concentrations Measured in Tianjin, China
    Liu, Yating
    Hai, Zhipeng
    You, Yan
    Zhang, Jiefeng
    Zhou, Jian
    EPIDEMIOLOGY, 2011, 22 (01) : S215 - S215
  • [36] Personal exposures to NO2 in the EXPOLIS-study:: relation to residential indoor, outdoor and workplace concentrations in Basel, Helsinki and Prague
    Kousa, A
    Monn, C
    Rotko, T
    Alm, S
    Oglesby, L
    Jantunen, MJ
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (20) : 3405 - 3412
  • [37] Characteristics and Relationships between Indoor and Outdoor PM2.5 in Beijing: A Residential Apartment Case Study
    Han, Yingjie
    Li, Xinghua
    Zhu, Tianle
    Lv, Dong
    Chen, Ying
    Hou, Li'an
    Zhang, Yinping
    Ren, Mingzhong
    AEROSOL AND AIR QUALITY RESEARCH, 2016, 16 (10) : 2386 - 2395
  • [38] Relationships between size-fractionated indoor and outdoor trace elements at four retirement communities in southern California
    Polidori, A.
    Cheung, K. L.
    Arhami, M.
    Delfino, R. J.
    Schauer, J. J.
    Sioutas, C.
    ATMOSPHERIC CHEMISTRY AND PHYSICS, 2009, 9 (14) : 4521 - 4536
  • [39] Personal indoor, and outdoor concentrations of PM2.5, particulate nitrate and elemental carbon for individuals with COPD in Los Angeles, CA
    Chang, LT
    Suh, HH
    Wheeler, A
    Koutrakis, P
    Lau, GKK
    Turpin, B
    Colome, S
    Phillips, T
    Yanosky, J
    Wallace, L
    EPIDEMIOLOGY, 2002, 13 (04) : S84 - S84
  • [40] Size-dependent PM10 indoor/outdoor/personal relationships for a wind-induced naturally ventilated airspace
    Liao, CM
    Chen, JW
    Huang, SJ
    ATMOSPHERIC ENVIRONMENT, 2003, 37 (22) : 3065 - 3075