Estimation of the temperature field in laser-induced hyperthermia experiments with a phantom

被引:16
|
作者
Lamien, Bernard [1 ]
Barreto Orlande, Helcio Rangel [1 ,2 ]
Bermeo Varon, Leonardo Antonio [1 ,3 ]
Queiroga Basto, Rodrigo Leite [1 ]
Enrique Elicabe, Guillermo [4 ,5 ]
dos Santos, Dilson Silva [2 ,6 ]
Cotta, Renato Machado [1 ]
机构
[1] Univ Fed Rio de Janeiro, Politecn COPPE, Dept Mech Engn, Cidade Univ,Caixa Postal 68503, BR-21941972 Rio De Janeiro, RJ, Brazil
[2] Univ Fed Rio de Janeiro, COPPE, Dept Nanotechnol Engn, Rio De Janeiro, Brazil
[3] Univ Santiago de Cali, Dept Bioengn, Santiago De Cali, Colombia
[4] Univ Mar del Plata, Inst Mat Sci & Technol INTEMA, Mar Del Plata, Buenos Aires, Argentina
[5] Natl Res Council CONICET, Buenos Aires, DF, Argentina
[6] Univ Fed Rio de Janeiro, Politecn COPPE, Dept Met & Mat Engn, Rio De Janeiro, Brazil
关键词
State estimation; particle filter; Monte Carlo; nanoparticles; STATE ESTIMATION; PARTICLE FILTER; COMBINED PARAMETER; CANCER; NANOPARTICLES; ABLATION; THERAPY;
D O I
10.1080/02656736.2018.1496283
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: One of the challenges faced during the hyperthermia treatment of cancer is to monitor the temperature distribution in the region of interest. The main objective of this work was to accurately estimate the transient temperature distribution in the heated region, by using a stochastic heat transfer model and temperature measurements. Methods: Experiments involved the laser heating of a cylindrical phantom, partially loaded with iron oxide nanoparticles. The nanoparticles were manufactured and characterized in this work. The solution of the state estimation problem was obtained with an algorithm of the Particle Filter method, which allowed for simultaneous estimation of state variables and model parameters. Measurements of one single sensor were used for the estimation procedure, which is highly desirable for practical applications in order to avoid patient discomfort. Results: Despite the large uncertainties assumed for the model parameters and for the coupled radiation-conduction model, discrepancies between estimated temperatures and internal measurements were smaller than 0.7 degrees C. In addition, the estimated fluence rate distribution was physically meaningful. Maximum discrepancies between the prior means and the estimated means were of 2% for thermal conductivity and heat transfer coefficient, 4% for the volumetric heat capacity and 3% for the irradiance. Conclusions: This article demonstrated that the Particle Filter method can be used to accurately predict the temperatures in regions where measurements are not available. The present technique has potential applications in hyperthermia treatments as an observer for active control strategies, as well as to plan personalized heating protocols.
引用
收藏
页码:279 / 290
页数:12
相关论文
共 50 条
  • [31] Temperature measurement in combustion flow field with femtosecond laser-induced filament
    Li Shuai-Yao
    Zhang Da-Yuan
    Gao Qiang
    Li Bo
    He Yong
    Wang Zhi-Hua
    ACTA PHYSICA SINICA, 2020, 69 (23)
  • [32] Laser-Induced Temperature Field and Thermal Stresses in the Elastic Homogeneous Material
    P. Klemm
    K. Rożniakowski
    A. Evtushenko
    Materials Science, 2003, 39 : 385 - 393
  • [33] Design of Experiments and Optimization of Laser-Induced Graphene
    Murray, Richard
    Burke, Micheal
    Iacopino, Daniela
    Quinn, Aidan J.
    ACS OMEGA, 2021, 6 (26): : 16736 - 16743
  • [34] Misalignment Effects in Laser-Induced Grating Experiments
    Kiefer, Johannes
    Sahlberg, Anna-Lena
    Hot, Dina
    Alden, Marcus
    Li, Zhongshan
    APPLIED SPECTROSCOPY, 2016, 70 (12) : 2025 - 2028
  • [35] Dynamic polariscopic imaging of laser-induced strain in a tissue phantom
    Inst d'Optique Appliquee, Lausanne, Switzerland
    Appl Phys Lett, 26 (3510-3512):
  • [36] Laser-induced photoacoustic spectroscopy investigation of colon phantom tissue
    James Joseph
    Krishnan Sathiyamoorthy
    T. Visalatchi
    V. M. Murukeshan
    Lye Sun Woh
    Applied Physics A, 2010, 101 : 567 - 571
  • [37] Dynamic polariscopic imaging of laser-induced strain in a tissue phantom
    Delacretaz, G
    Walsh, JT
    Asshauer, T
    APPLIED PHYSICS LETTERS, 1997, 70 (26) : 3510 - 3512
  • [38] FATAL AIR-EMBOLISM AS A COMPLICATION OF LASER-INDUCED HYPERTHERMIA
    SCHRODER, TM
    PUOLAKKAINEN, PA
    HAHL, J
    RAMO, OJ
    LASERS IN SURGERY AND MEDICINE, 1989, 9 (02) : 183 - 185
  • [39] Selective laser-induced hyperthermia for the treatment of spontaneous tumors in dogs
    Lucroy, Michael D.
    Chen, Wei R.
    Ridgway, Tisha D.
    Higbee, Russell G.
    Bartels, Kenneth E.
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2002, 10 (3-4) : 237 - 243
  • [40] Laser-induced hyperthermia for treatment of granulation tissue growth in rats
    Landsberg, Roee
    DeRowe, Ari
    Katzir, Abraham
    Shtabsky, Alexander
    Fliss, Dan M.
    Gil, Ziv
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2009, 140 (04) : 480 - 486