A Row-Column Array for Ultrasound-Based Tissue Anisotropy Measurement

被引:0
|
作者
Wu, Huaiyu [1 ]
Kim, Jinwook [1 ]
Jiang, Xiaoning [1 ]
Hossain, Md Murad [2 ]
Gallippi, Caterina M. [2 ]
机构
[1] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27606 USA
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
关键词
Row-column array; anisotropy; ARFI; Orthogonal pushing beams; Electronic rotation of the pushing beams; MECHANICAL-PROPERTIES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Degree of anisotropy (DoA) in mechanical properties is a rapidly emerging biomarker for tissue pathology that has shown to be correlated to fatty infiltration in dystrophic skeletal muscle. DoA can be assessed either using ratio of shear wave velocities (SWV) or using acoustic radio forced impulse (ARFI)-induced peak displacements (PD) measured along versus across the muscle fibers. Whether using SWV or PD as a basis, DoA expressed as the ratio of values requires 90 degrees transducer rotation when a linear array is employed. This large rotation angle is prone to misalignment error. Though fully sampled matrix arrays could enable electronic aperture rotation and reduce misalignment errors, their high fabrication cost and complicated fabrication procedures are challenges. To solve these problems, a custom row-column array is proposed in this paper. The row-column array contains 3 X 64 elements. The orthogonal pushing beam can be realized by x group pushing beam in which 5 rows on lateral-direction are fired together and the y-pushing beam in which center column in elevational-direction are fired. A custom designed flex circuit was applied to fabricate the array with simpler electrode connection than fully sampled matrix array. The performance of the array is evaluated in Field II simulation and experiment. The output pressure was 0.56 MPa output under a 40 Vpp excitation with similar beam-profile in orthogonal directions. With the capability of rotating the pushing beam electronically, the array has the potential for DoA assessment with reduce misalignment errors.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] 4D Functional Imaging of the Rat Brain Using a Large Aperture Row-Column Array
    Sauvage, Jack
    Poree, Jonathan
    Rabut, Claire
    Ferin, Guillaume
    Flesch, Martin
    Rosinski, Bogdan
    An Nguyen-Dinh
    Tanter, Mickael
    Pernot, Mathieu
    Deffieux, Thomas
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1884 - 1893
  • [42] Rethinking the crop row detection pipeline: An end-to-end method for crop row detection based on row-column attention
    Li, Boliao
    Li, Dongfang
    Wei, Zhenbo
    Wang, Jun
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2024, 225
  • [43] Row-Column Separated Attention Based Low-Light Image/Video Enhancement
    Dong, Chengqi
    Cao, Zhiyuan
    Qi, Tuoshi
    Wu, Kexin
    Gao, Yixing
    Tang, Fan
    COMPUTER GRAPHICS FORUM, 2024, 43 (06)
  • [44] Compensated Row-Column Ultrasound Imaging Systems with Data-Driven Point Spread Function Learning
    Ben Daya, Ibrahim
    Yeow, John T. W.
    Wong, Alexander
    IMAGE ANALYSIS AND RECOGNITION (ICIAR 2019), PT II, 2019, 11663 : 429 - 441
  • [45] Thought-based row-column scanning communication board for individuals with cerebral palsy
    Scherer, Reinhold
    Billinger, Martin
    Wagner, Johanna
    Schwarz, Andreas
    Hettich, Dirk Tassilo
    Bolinger, Elaina
    Lloria Garcia, Mariano
    Navarro, Juan
    Mueller-Putz, Gernot
    ANNALS OF PHYSICAL AND REHABILITATION MEDICINE, 2015, 58 (01) : 14 - 22
  • [46] DIGITAL IMAGE ENCRYPTION ALGORITHM BASED ON SPATIOTEMPORAL CHAOS AND ROW-COLUMN CIRCULAR SHIFT
    Xie, Bangyong
    Wang, Deshi
    PROCEEDINGS OF THE 38TH INTERNATIONAL CONFERENCE ON COMPUTERS AND INDUSTRIAL ENGINEERING, VOLS 1-3, 2008, : 1008 - 1012
  • [47] 3-D Super Resolution Imaging using a 62+62 Elements Row-Column Array
    Jensen, Jorgen Arendt
    Schou, Mikkel
    Ommen, Martin Lind
    Oygard, Sigrid Husebo
    Sams, Thomas
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Larsen, Niels Bent
    Beers, Christopher
    Tomov, Borislav Gueorguiev
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1838 - 1841
  • [48] Compensated Row-Column Ultrasound Imaging System Using Fisher Tippett Multilayered Conditional Random Field Model
    Ben Daya, Ibrahim
    Chen, Albert I. H.
    Shafiee, Mohammad Javad
    Wong, Alexander
    Yeow, John T. W.
    PLOS ONE, 2015, 10 (12):
  • [49] Acoustical cross-talk in row-column addressed 2-D transducer arrays for ultrasound imaging
    Christiansen, Thomas Lehrmann
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    ULTRASONICS, 2015, 63 : 174 - 178
  • [50] Row-column decomposition based 2D transform optimization on subword parallel processors
    Sihvo, T
    Niittylahti, J
    ISSCS 2005: INTERNATIONAL SYMPOSIUM ON SIGNALS, CIRCUITS AND SYSTEMS, VOLS 1 AND 2, PROCEEDINGS, 2005, : 99 - 102