A Row-Column Array for Ultrasound-Based Tissue Anisotropy Measurement

被引:0
|
作者
Wu, Huaiyu [1 ]
Kim, Jinwook [1 ]
Jiang, Xiaoning [1 ]
Hossain, Md Murad [2 ]
Gallippi, Caterina M. [2 ]
机构
[1] North Carolina State Univ, Dept Mech & Aerosp Engn, Raleigh, NC 27606 USA
[2] Univ N Carolina, Dept Biomed Engn, Chapel Hill, NC 27599 USA
关键词
Row-column array; anisotropy; ARFI; Orthogonal pushing beams; Electronic rotation of the pushing beams; MECHANICAL-PROPERTIES;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Degree of anisotropy (DoA) in mechanical properties is a rapidly emerging biomarker for tissue pathology that has shown to be correlated to fatty infiltration in dystrophic skeletal muscle. DoA can be assessed either using ratio of shear wave velocities (SWV) or using acoustic radio forced impulse (ARFI)-induced peak displacements (PD) measured along versus across the muscle fibers. Whether using SWV or PD as a basis, DoA expressed as the ratio of values requires 90 degrees transducer rotation when a linear array is employed. This large rotation angle is prone to misalignment error. Though fully sampled matrix arrays could enable electronic aperture rotation and reduce misalignment errors, their high fabrication cost and complicated fabrication procedures are challenges. To solve these problems, a custom row-column array is proposed in this paper. The row-column array contains 3 X 64 elements. The orthogonal pushing beam can be realized by x group pushing beam in which 5 rows on lateral-direction are fired together and the y-pushing beam in which center column in elevational-direction are fired. A custom designed flex circuit was applied to fabricate the array with simpler electrode connection than fully sampled matrix array. The performance of the array is evaluated in Field II simulation and experiment. The output pressure was 0.56 MPa output under a 40 Vpp excitation with similar beam-profile in orthogonal directions. With the capability of rotating the pushing beam electronically, the array has the potential for DoA assessment with reduce misalignment errors.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Conformable Row-Column Ultrasound Arrays for Abdominal Imaging
    Lu, Jian-yu
    Jiang, Xiaoning
    2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, : 1753 - 1756
  • [2] 3-D Ultrasound Imaging Performance of a Row-Column Addressed 2-D Array Transducer: A Measurement Study
    Rasmussen, Morten Fischer
    Jensen, Jorgen Arendt
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1452 - 1455
  • [3] Demonstration of a Thermally Coupled Row-Column SNSPD Imaging Array
    Allmaras, Jason P.
    Wollman, Emma E.
    Beyer, Andrew D.
    Briggs, Ryan M.
    Korzh, Boris A.
    Bumble, Bruce
    Shaw, Matthew D.
    NANO LETTERS, 2020, 20 (03) : 2163 - 2168
  • [4] A 1.5-D Array for Acoustic Radiation Force (ARF)-Induced Peak Displacement-Based Tissue Anisotropy Assessment With a Row-Column Excitation Method
    Wu, Huaiyu
    Hossain, Md Murad
    Kim, Howuk
    Gallippi, Caterina M.
    Jiang, Xiaoning
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (04) : 1278 - 1287
  • [5] Diverging Polymer Acoustic Lens Design for High-Resolution Row-Column Array Ultrasound Transducers
    Audoin, Melanie
    Salari, Ali
    Tomov, Borislav Gueorguiev
    Pedersen, Kasper Flong
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2024, 71 (01) : 202 - 213
  • [6] 3-D Spatial Compounding Using a Row-Column Array
    Awad, Samer I.
    Yen, Jesse T.
    ULTRASONIC IMAGING, 2009, 31 (02) : 120 - 130
  • [7] Accurate prediction of transmission through a lensed row-column addressed array
    Oygard, Sigrid H.
    Audoin, Melanie
    Austeng, Andreas
    Thomsen, Erik V.
    Stuart, Matthias B.
    Jensen, Jorgen A.
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2022, 151 (05): : 3207 - 3218
  • [8] BCB polymer based row-column addressed CMUT
    Havreland, Andreas Spandet
    Ommen, Martin Lind
    Silvestre, Chantal
    Engholm, Mathias
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [9] Flexible PZT-Based Row-Column Addressed 2-D PMUT Array
    Joshi, Sanjog Vilas
    Sadeghpour, Sina
    Kraft, Michael
    IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 2024, 71 (11) : 1616 - 1626
  • [10] Construction of resolvable row-column designs based on contractions
    Wright, CL
    John, JA
    Whitaker, D
    Williams, ER
    AUSTRALIAN & NEW ZEALAND JOURNAL OF STATISTICS, 2005, 47 (01) : 119 - 124