Evaluation of two devices for point-of-care testing of haemoglobin in neonatal pigs

被引:19
|
作者
Kutter, Annette P. N. [1 ]
Mauch, Jacqueline Y. [2 ,3 ]
Riond, Barbara [4 ]
Martin-Jurado, Olga [1 ]
Spielmann, Nelly [3 ]
Weiss, Markus [3 ]
Bettschart-Wolfensberger, Regula [1 ]
机构
[1] Univ Zurich, Vetsuisse Fac, Equine Dept, Sect Anaesthesiol, CH-8057 Zurich, Switzerland
[2] Kantonsspital Aarau, Dept Anaesthesia & Perioperat Med, CH-5000 Aarau, Switzerland
[3] Univ Childrens Hosp, Dept Anaesthesia, CH-8032 Zurich, Switzerland
[4] Univ Zurich, Vetsuisse Fac, Clin Lab, CH-8057 Zurich, Switzerland
关键词
Quality assurance/control; pigs; diagnostic assay; haematology; PORTABLE CLINICAL ANALYZER; PACKED CELL-VOLUME; I-STAT; CARDIOPULMONARY BYPASS; BLOOD; HEMATOCRIT; ANEMIA; IRON; HEMOCUE(R); COULTER;
D O I
10.1258/la.2011.011086
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
In veterinary medicine, point-of-care testing (POCT) techniques have become popular, since they provide immediate results and only small amounts of blood are needed. However, their accuracy is controversial. Pigs are often used for research purposes and accurate measurement of haemoglobin (Hb) is important during invasive procedures. The aim of this study was to evaluate two different Hb POCT devices in neonatal pigs. A prospective study with 57 pigs of 3-6 weeks of age, weighing 4.1-6.2 kg (median 5.1 kg) was performed. Fifty-seven blood samples were analysed for Hb using a conductivity-based and a photometrical POCT device and compared with a photometrical reference method. Statistical analysis was performed with Bland Altman analysis, Spearman correlation and Passing Bablok regression analysis. Hb values ranged from 32 to 108 g/L (median 80 g/L) using the reference method. The bias of the photometrical method (HemoCue (R)) to the reference method was -1 g/L, with limits of agreement (LOA) of -7 to 6 g/L. The conductivity-based method (i-STAT (R)) had a bias of -15 g/L with LOA from -24 to -6 g/L. There was a significant association between protein values and the bias of i-STAT versus CellDyn (r(2) = 0.27, P < 0.05) but not with the bias of HennoCue versus CellDyn (r(2) = 0.001, P = 0.79). The lower the protein values were, the lower the Hb values were measured by the i-STAT. The conductivity-based measurement of Hb constantly underestimated Hb values, whereas the photometrical method demonstrated a better accuracy and is therefore more reliable for on-site measurement of Hb in pigs.
引用
收藏
页码:65 / 70
页数:6
相关论文
共 50 条
  • [1] Haemoglobin point-of-care testing
    Scicluna, M.
    Wirth, F.
    Azzopardi, L. M.
    [J]. INTERNATIONAL JOURNAL OF CLINICAL PHARMACY, 2020, 42 (01) : 239 - 239
  • [2] Neonatal point-of-care testing
    Naghdi, Tina
    Sharifi, Amir Reza
    Tabatabaee, Raziyeh Sadat
    Azizi, Elmira
    Kiani, Mohammad Ali
    Golmohammadi, Hamed
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2024, 175
  • [3] Portable point-of-care device for haemoglobin testing
    Mohan, Alladi
    [J]. NATIONAL MEDICAL JOURNAL OF INDIA, 2014, 27 (03): : 186 - 187
  • [4] Accuracy of point-of-care testing devices for haemoglobin in the operating room: meta-analysis
    Ahn, Hilalion
    Lenet, Tori
    Gilbert, Richard W. D.
    Mallick, Ranjeeta
    Shaw, Julie L., V
    Fergusson, Dean A.
    McIsaac, Daniel I.
    Martel, Guillaume
    [J]. BJS OPEN, 2024, 8 (01):
  • [5] Point-of-care testing of neonatal coagulation
    Tan, K
    Booth, D
    Newell, SJ
    Dear, PRF
    Hughes, C
    Richards, M
    [J]. CLINICAL AND LABORATORY HAEMATOLOGY, 2006, 28 (02): : 117 - 121
  • [6] Comparison of two point-of-care testing devices for lipid profiling
    Og, O'Donovan D.
    Sahm, L.
    Shannon, N.
    Byrne, S.
    [J]. PHARMACOEPIDEMIOLOGY AND DRUG SAFETY, 2010, 19 (06) : 655 - 655
  • [7] Evaluation of various methods of point-of-care testing of haemoglobin concentration in blood donors
    Singh, Abhay
    Dubey, Anju
    Sonker, Atul
    Chaudhary, Rajendra
    [J]. BLOOD TRANSFUSION, 2015, 13 (02) : 233 - 239
  • [8] Electrochemiluminescence devices for point-of-care testing
    Ying, Xudong
    Zhou, Lin
    Fu, Wenxuan
    Wang, Yafeng
    Su, Bin
    [J]. SENSORS & DIAGNOSTICS, 2023, 2 (03): : 480 - 491
  • [9] Portable liquid chromatography for point-of-care testing of glycated haemoglobin
    Li, Ding
    Chen, Haiyan
    Ren, Shuang
    Zhang, Yanfang
    Yang, Yang
    Chang, Honglong
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2020, 305
  • [10] Flexible Analytical Devices for Point-of-Care Testing
    Tsutsui, Hideaki
    Lillehoj, Peter B.
    [J]. SLAS TECHNOLOGY, 2020, 25 (01): : 6 - 8