STUDY ON CONTROL STRATEGY OF HYDROGEN RISK IN SMALL CONTAINMENT UNDER SEVERE ACCIDENT

被引:0
|
作者
Zou Zhiqiang [1 ]
Zhang Ming [1 ]
Peng Huanhuan [1 ]
Hou Liqiang [1 ]
Deng Chunrui [1 ]
Qiao Xuedong [2 ]
机构
[1] Nucl Power Inst China, Sci & Technol Reactor Syst Design Technol Lab, Chengdu, Sichuan, Peoples R China
[2] Minist Environm Protect PR China, Nucl & Radiat Safety Ctr, Beijing, Peoples R China
关键词
Small reactor steel containment; Hydrogen Risk; Passive Containment Cooling System (PCCS); Passive Autocatalytic Recombiner (PAR);
D O I
暂无
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Hydrogen combustion or detonation happened in the containment within the process of the small reactor severe accident may threaten the integrity of the containment. In this paper, based on systemic design of the Small Modular Reactor (SMR) surrounded by the steel containment, an innovatory combustible gas control strategy which using the passive containment cooling system (PCCS) and passive autocatalytic recombiners (PARs) is made to control the hydrogen risk in the small steel containment. A severe accident hydrogen risk analysis model is built by the integrative severe accident analysis program MELCOR, the validity of the strategy is analyzed at a typical severe accident. With this understanding, a three-dimensional computed fluid dynamics hydrogen behavior analysis model of the small steel containment is established by GASFLOW code, and the gas distribution non-uniformity in the containment is analyzed. The result shows that the steam condensation process in the containment could be slowed down by controlling the action of PCCS, and the steam concentration in the containment could be in the range of high level, while the oxygen concentration could be in the range of low level. If the PARS were added, the PARs could consume the hydrogen and oxygen in the containment sustainedly. The containment atmosphere could be in an inerted condition during the accident process, even though the hydrogen concentration in the containment is high. The gas distribution non-uniformity analysis result shows that oxygen concentration was low in the extent of high hydrogen concentration and high steam concentration, the steam, oxygen and hydrogen distribution non-uniformity would not affect the inerted atmosphere of containment.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Analysis of prestressed concrete containment vessel (PCCV) under severe accident loading
    Noh, Sang Hoon
    Moon, Il Hwan
    Lee, Jong Bo
    Kim, Jong Hak
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2008, 40 (01) : 77 - 86
  • [32] An Effect of Containment Filtered Venting System on Scale of Contamination Under Severe Accident
    Jeon, Ju Young
    Lee, Jai-ki
    ATW-INTERNATIONAL JOURNAL FOR NUCLEAR POWER, 2016, 61 (02): : 110 - +
  • [33] PRELIMINARY ANALYSIS OF HYDROGEN BEHAVIOR USING GASFLOW-MPI IN THE OPR1000 CONTAINMENT UNDER A SEVERE ACCIDENT CONDITION
    Go, JongWook
    Hong, TaeHyub
    Seo, MiRo
    PROCEEDINGS OF THE 26TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2018, VOL 7, 2018,
  • [34] SIMULATION OF GAS STRATIFICATION BUILD-UP IN THE CONTAINMENT UNDER SEVERE ACCIDENT CONDITIONS
    Andreani, Michele
    PROCEEDINGS OF THE 22ND INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2014, VOL 2B, 2014,
  • [35] Hydrogen risk analysis in small containment with a pressure suppression tank
    Zou, Zhiqiang
    Zhang, Hang
    Sun, Hongping
    Luo, Yuejian
    Deng, Jian
    Peng, Huanhuan
    Zhang, Ming
    Qiu, Zhifang
    Jiang, Xiaowei
    PROGRESS IN NUCLEAR ENERGY, 2024, 169
  • [36] Analysis of hydrogen distribution and control in NPP containment during severe accidents
    Fang, Li-Kai
    Chen, Song
    Zhou, Quan-Fu
    Hedongli Gongcheng/Nuclear Power Engineering, 2006, 27 (SUPPL. 1): : 18 - 22
  • [37] Heat and mass transfer of high performance concrete for reactor containment under severe accident conditions
    Shekarchi, M
    Debicki, G
    Billard, Y
    FIRE TECHNOLOGY, 2003, 39 (01) : 63 - 71
  • [38] Nonlinear Finite Element Analysis of Prestressed Concrete Containment Vessel under Severe Accident Loads
    Song Jin
    Zhongcheng Li
    Tianyun Lan
    Zhanfa Dong
    Jinxin Gong
    KSCE Journal of Civil Engineering, 2020, 24 : 816 - 825
  • [39] Strategy Validation of Severe Accident Management Guidance for Qinshan-I NPP under Typical Severe Accident Sequence
    Wang Y.
    Wei Y.-S.
    Shi X.-L.
    Zhang Y.-C.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2017, 51 (04): : 666 - 670
  • [40] Study on containment pressure response with passive containment cooling system performance under design basis accident
    Wang, Yan
    Yang, Yanning
    PROGRESS IN NUCLEAR ENERGY, 2017, 94 : 22 - 35