Determination of cadmium by differential pulse adsorptive stripping voltammetry in the present of captopril

被引:7
|
作者
Gholivand, MB [1 ]
Nassab, HR [1 ]
Mosavat, AR [1 ]
机构
[1] Razi Univ, Dept Chem, Kermanshah, Iran
关键词
cadmium; captopril; stripping voltammetry;
D O I
10.1002/elan.200403263
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new method is presented for determination of cadmium based on cathodic adsorptive stripping of the complex of cadmium with captopril,1-[(2S)-3-mercapto-2-methylpropionyl]-L-praline (CPL) at a hanging mercury drop electrode(HMDE). The most suitable operating conditions and parameters, such as pH, deposition potential, deposition time, ligand concentration, and others were selected and the determination of cadmium from aqueous solutions using the standard additions method was possible. Under the optimum conditions and for an accumulation time of 60 s, the measured peak current is proportional to the concentration of cadmium over the range of 1 - 300 nM. The limit of detection at S/N ratio of 3 was 0.3 nM and a relative standard deviation of 2.5% at 0.1 mu M was achieved. The interference of other cations and anions was studied. The method was designed in order to determination of Cd in four analytical grade salts, with satisfactory results.
引用
收藏
页码:1985 / 1990
页数:6
相关论文
共 50 条
  • [41] DIFFERENTIAL-PULSE ADSORPTIVE STRIPPING VOLTAMMETRY OF THE HERBICIDES METAMITRON AND ISOMETIOZINE
    GOICOLEA, MA
    ARRANZ, JF
    BARRIO, RJ
    DEBALUGERA, ZG
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1991, 339 (03): : 166 - 168
  • [42] Determination of nifedipine by differential pulse adsorptive stripping polarography
    Shapovalov, VA
    JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (02) : 157 - 158
  • [43] Determination of Nifedipine by Differential Pulse Adsorptive Stripping Polarography
    V. A. Shapovalov
    Journal of Analytical Chemistry, 2002, 57 : 157 - 158
  • [44] Determination of thallium by differential pulse anodic stripping voltammetry
    Karbowska, Bozena
    Zembrzuski, Wlodzimierz
    Wojtkowiak, Tomasz
    Lukaszewski, Zenon
    PRZEMYSL CHEMICZNY, 2014, 93 (06): : 978 - 982
  • [45] DETERMINATION OF URANIUM BY ADSORPTIVE STRIPPING VOLTAMMETRY
    LAM, NK
    KALVODA, R
    KOPANICA, M
    ANALYTICA CHIMICA ACTA, 1983, 154 (NOV) : 79 - 86
  • [46] COBALT IN DUTCH MILK POWDER - DETERMINATION BY DIFFERENTIAL-PULSE ADSORPTIVE CATHODIC-STRIPPING VOLTAMMETRY
    KOOPS, J
    KLOMP, H
    NETHERLANDS MILK AND DAIRY JOURNAL, 1991, 45 (02): : 127 - 138
  • [47] DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR MERCURY DETERMINATION
    Verestiuc, Paul C.
    Tucaliuc, Oana-Maria
    Breaban, Iuliana G.
    Cretescu, Igor
    Nemtoi, Gheorghe
    ACTA CHEMICA IASI, 2015, 23 (01) : 13 - 24
  • [48] A study of the determination of the hypertensive drug captopril by square wave cathodic adsorptive stripping voltammetry
    Ioannides, X
    Economou, A
    Voulgaropoulos, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (02) : 309 - 316
  • [49] Determination of palladium by adsorptive stripping voltammetry
    Georgieva, M
    Pihlar, B
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (07): : 874 - 880
  • [50] DETERMINATION OF TRICHLOROBIPHENYL BY ADSORPTIVE STRIPPING VOLTAMMETRY
    LAM, NK