Closed-Loop Communication Improves Task Completion in Pediatric Trauma Resuscitation

被引:66
|
作者
Abd El-Shafy, Ibrahim [1 ,2 ,4 ]
Delgado, Jennifer [1 ]
Akerman, Meredith [2 ]
Bullaro, Francesca [1 ]
Christopherson, Nathan A. M. [1 ,4 ]
Prince, Jose M. [1 ,2 ,3 ]
机构
[1] Hofstra Northwell Sch Med, Cohen Childrens Med Ctr, Dept Surg, New Hyde Pk, NY USA
[2] Feinstein Inst Med Res, Manhasset, NY USA
[3] Northwell Hlth Syst, Trauma Inst, New York, NY USA
[4] Maimonadies Med Ctr, Dept Surg, Brooklyn, NY USA
关键词
pediatric trauma; trauma video review; closed-Loop communication; time to task completion; trauma team leader; OPERATING-ROOM; FAILURES; TEAMS; CLASSIFICATION; PERFORMANCE; INFORMATION; CHECKLIST; TEAMWORK; SURGEONS; PATIENT;
D O I
10.1016/j.jsurg.2017.06.025
中图分类号
G40 [教育学];
学科分类号
040101 ; 120403 ;
摘要
BACKGROUND: Pediatric trauma care requires effective and clear communication in a time-sensitive manner amongst a variety of disciplines. Programs such as Crew Resource Management in aviation have been developed to systematically prevent errors. Similarly, teamSTEPPS has been promoted in healthcare with a strong focus on communication. We aim to evaluate the ability of closed-loop communication to improve time-to-task completion in pediatric trauma activations. METHODS: All pediatric trauma activations from January to September, 2016 at an American College of Surgeons verified level I pediatric trauma center were video recorded and included in the study. Two independent reviewers identified and classified all verbal orders issued by the trauma team leader for order audibility, directed responsibility, check-back, and time-to-task-completion. The impact of pre-notification and level of activation on time-to-task-completion was also evaluated. All analyses were performed using SAS version 9.4(SAS Institute Inc., Cary, NC). RESULTS: In total, 89 trauma activation videos were reviewed, with 387 verbal orders identified. Of those, 126 (32.6%) were directed, 372(96.1%) audible, and 101 (26.1%) closed-loop. On average each order required 3.85 minutes to be completed. There was a significant reduction in time-to-task-completion when closed-loop communication was utilized (p < 0.0001). Orders with closed-loop communication were completed 3.6 times sooner as compared to orders with an open-loop [HR = 3.6 (95% CI: 2.5, 5.3)]. There was not a significant difference in time-to-task-completion with respect to pre-notification by emergency service providers (p < 0.6100). [HR = 1.1 (95% CI: 0.9, 1.3)]. There was also not a significant difference in time-to-task-completion with respect to level of trauma team activation (p < 0.2229). [HR = 1.3 (95% CI: 0.8, 2.1)]. CONCLUSION: While closed-loop communication prevents medical errors, our study highlights the potential to increase the speed and efficiency with which tasks are completed in the setting of pediatric trauma resuscitation. Trauma drills and systems of communication that emphasize the use of closed-loop communication should be incorporated into the training of trauma team leaders. (C) 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:58 / 64
页数:7
相关论文
共 50 条
  • [41] Closed-loop control in FDDI-based factory communication systems
    Westphal, H
    Renganathan, S
    [J]. ETFA '97 - 1997 IEEE 6TH INTERNATIONAL CONFERENCE ON EMERGING TECHNOLOGIES AND FACTORY AUTOMATION PROCEEDINGS, 1997, : 104 - 108
  • [42] Revisiting the Closed-Loop Model and the Nature of mRNA 5′-3′ Communication
    Vicens, Quentin
    Kieft, Jeffrey S.
    Rissland, Olivia S.
    [J]. MOLECULAR CELL, 2018, 72 (05) : 805 - 812
  • [43] Closed-Loop Communication Maintenance Management Based on Early Warning Analysis
    Dong Gang-song
    [J]. PROCEEDINGS OF THE 2017 5TH INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS AND COMPUTING TECHNOLOGY (ICMMCT 2017), 2017, 126 : 1555 - 1558
  • [44] A communication model for reducing the bullwhip effect in closed-loop supply chain
    Malekinejad, Pooria
    Ziaeian, Mehran
    Bamakan, Seyed Mojtaba Hosseini
    [J]. ADVANCES IN INDUSTRIAL AND MANUFACTURING ENGINEERING, 2022, 5
  • [45] Tradeoffs Between Wireless Communication and Computation in Closed-loop Implantable Devices
    Salam, M. Tariqus
    Kassiri, Hossein
    Soltani, Nima
    He, Haoyu
    Velazquez, Jose Luis Perez
    Genov, Roman
    [J]. 2016 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2016, : 1838 - 1841
  • [46] Closed-loop dynamics of cooperative vehicle formations with parallel estimators and communication
    Smith, Roy S.
    Hadaegh, Fred Y.
    [J]. IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 2007, 52 (08) : 1404 - 1414
  • [47] Powering and Communication for OMNI: A Distributed and Modular Closed-Loop Neuromodulation Device
    Moin, Ali
    Alexandrov, George
    Johnson, Benjamin C.
    Izyumin, Igor
    Burghardt, Fred
    Shah, Kedar
    Pannu, Sat
    Alon, Elad
    Muller, Rikky
    Rabaey, Jan M.
    [J]. 2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 4471 - 4474
  • [48] Development of closed-loop drug infusion system for automated hemodynamic resuscitation in septic shock
    Uemura, K.
    Kawada, T.
    Zheng, C.
    Li, M.
    Sugimachi, M.
    [J]. EUROPEAN HEART JOURNAL, 2017, 38 : 591 - 592
  • [49] Closed-loop Controller for Chest Compression During Cardiopulmonary Resuscitation: A Computer Simulation Study
    Zhang, Guang
    Zheng, Jie-Wen
    Wu, Jian
    Wu, Tai-Hu
    [J]. JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (05) : 313 - 322
  • [50] Closed-Loop Audit on Upper Limb Bite Injuries at a Major Trauma Centre
    Yousefi Azimi, D.
    Paraoan, V
    Jones, M.
    [J]. BRITISH JOURNAL OF SURGERY, 2024, 111