A hybrid (iron-fat-water) phantom for liver iron overload quantification in the presence of contaminating fat using magnetic resonance imaging

被引:10
|
作者
Mobini, Nazanin [1 ,2 ]
Malekzadeh, Malakeh [2 ,3 ]
Haghighatkhah, Hamidreza [4 ]
Rad, Hamidreza Saligheh [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Sch Med, Dept Med Phys & Biomed Engn, Tehran, Iran
[2] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Inst Adv Med Technol, Quantitat MR Imaging & Spect Grp QMISG,Res Ctr Ce, Keshavarz Blvd, Tehran 1419733141, Iran
[3] Iran Univ Med Sci IUMS, Sch Med, Med Phys Dept, Tehran, Iran
[4] Shahid Beheshti Univ Med Sci SBMU, Shohada E Tajrish Hosp, Dept Radiol, Tehran, Iran
关键词
Iron-fat-water phantom; Magnetic resonance imaging; Iron overload; Fatty liver; MRI; IMAGES;
D O I
10.1007/s10334-019-00795-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective Assessment of iron content in the liver is crucial for diagnosis/treatment of iron-overload diseases. Nonetheless, T-2*-based methods become challenging when fat and iron are simultaneously present. This study proposes a phantom design concomitantly containing various concentrations of iron and fat suitable for devising accurate simultaneous T-2* and fat quantification technique. Materials and methods A 46-vial iron-fat-water phantom with various iron concentrations covering clinically relevant T-2* relaxation time values, from healthy to severely overloaded liver and wide fat percentages ranges from 0 to 100% was prepared. The phantom was constructed using insoluble iron (II, III) oxide powder containing microscale particles. T-2*-weighted imaging using multi-gradient-echo (mGRE) sequence, and chemical shift imaging spin-echo (CSI-SE) Magnetic Resonance Spectroscopy (MRS) data were considered for the analysis. T-2* relaxation times and fat fractions were extracted from the MR signals to explore the effects of fat and iron overload. Results Size distribution of iron oxide particles for Magnetite fits with a lognormal function with a mean size of about 1.17 mu m. Comparison of FF color maps, estimated from bi- and mono-exponential model indicated that single-T-2* fitting model resulted in lower NRMSD. Therefore, T-2* values from the mono-exponential signal equation were used and expressed the relationship between relaxation time value across all iron (Fe) and fat concentration as Fe=-28.02+302.84T2*-0.045FF with R-squared = 0.89. Discussion The proposed phantom design with microsphere iron particles closely simulated the single-T-2* behavior of fatty iron-overloaded liver in vivo.
引用
收藏
页码:385 / 392
页数:8
相关论文
共 50 条
  • [21] Computed Tomography and Magnetic Resonance Imaging in Liver Iron Overload: From Precise Quantification to Prognosis Assessment
    Zhou, Xinrui
    Jia, Xinyuan
    Chen, Yidi
    Song, Bin
    BIOMEDICINES, 2024, 12 (11)
  • [22] R* magnetic resonance imaging (MRI) of the liver for patients with iron overload
    Hankins, Jane S.
    McCarville, M. Beth
    Loeffler, Ralph
    Song, Ruitian
    Ware, Russell E.
    Hansbury, Eileen
    Rieman, Martha
    Mortier, Nicole
    Smeltzer, Matthew
    Li, Chin-Shang
    Hoffer, Fred
    Hillenbrand, Claudia
    BLOOD, 2007, 110 (11) : 785A - 785A
  • [23] A robust method for assessment of iron overload in liver by magnetic resonance imaging
    Positano, Vincenzo
    Salani, Benedetta
    Scattini, Barbara
    Santarelli, Maria F.
    Ramazzotti, Anna
    Pepe, Alessia
    Lombardi, Massimo
    Landini, Luigi
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2895 - +
  • [24] Role of liver magnetic resonance imaging in hyperferritinaemia and the diagnosis of iron overload
    Axel, Ruefer
    Christine, Bapst
    Rudolf, Benz
    Jens, Bremerich
    Nathan, Cantoni
    Laura, Infanti
    Kaveh, Samii
    Mathias, Schmid
    Jean-Paul, Vallee
    SWISS MEDICAL WEEKLY, 2017, 147
  • [25] Evaluation of myocardial iron overload using magnetic resonance imaging
    Mavrogeni, Sophie
    BLOOD TRANSFUSION, 2009, 7 (03) : 183 - 187
  • [26] Quantification of liver fat infiltration by magnetic resonance
    Herrera, Rodrigo
    Penaloza, Francisco
    Arrietal, Cristobal
    Zacconi, Flavia
    Saavedra, Victor
    Saavedra, Carla
    Branes, Cecilia
    Hack, Thomas
    Uribe, Sergio
    REVISTA MEDICA DE CHILE, 2019, 147 (07) : 821 - 827
  • [27] Magnetic resonance imaging measurement of iron overload
    Wood, John C.
    CURRENT OPINION IN HEMATOLOGY, 2007, 14 (03) : 183 - 190
  • [28] Liver iron overload and fat content analyzed by magnetic resonance contribute to evaluatingthe progression of chronic hepatitis B
    Luo, Jinni
    Liu, Zhenzhen
    Wang, Qian
    Tan, Siwei
    BIOMEDICAL REPORTS, 2024, 20 (02)
  • [29] Fat and Water Magnetic Resonance Imaging
    Bley, Thorsten A.
    Wieben, Oliver
    Francois, Christopher J.
    Brittain, Jean H.
    Reeder, Scott B.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (01) : 4 - 18
  • [30] Fat Content Effect in the Measurement of T2* for Iron Quantification in the Liver in Patients With Suspected Myocardial Iron Overload
    Flavia P Junqueira
    Juliano L Fernandes
    Gustavo A Pinto
    Sandra R Loggetto
    Maria Cristina Purini