Assessment of mini-implant displacement using cone beam computed tomography

被引:26
|
作者
Alves, Matheus, Jr. [1 ]
Baratieri, Carolina [1 ]
Nojima, Lincoln Issamu [1 ]
机构
[1] Univ Fed Rio de Janeiro, Fac Dent, Dept Orthodont, Rio De Janeiro, Brazil
关键词
CBCT; mini-implant; stability; orthodontics; ORTHODONTIC ANCHORAGE; PROJECTION ERRORS; POSTERIOR TEETH; STABILITY; MINISCREWS; INTRUSION; CEPHALOMETRY; EXTRACTION; APPLIANCES; MAXILLARY;
D O I
10.1111/j.1600-0501.2010.02092.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To assess, through cone beam computed tomography (CBCT), the mini-implants' stability and behaviour when submitted to orthodontic force during upper molars' intrusion. Material and methods: Forty-one mini-implants were divided into two groups: 30 in the buccal and palatal mini-implants group (BPMI), inserted into buccal and palatal sides, and 11 in the midpalatal mini-implants group (MPMI), inserted into midpalatal suture. One day after insertion, a 200 gf was applied on the mini-implants during a 5-month period. CBCT was performed twice: before force application (CBCT 1) and 5 months later (CBCT 2). For mini-implant displacement assessment, the distance of mini-implants' head (HMI) and tail (TMI) to coronal, sagittal and axial planes was measured at CBCT 1 and 2. Results: For the BPMI group, the displacement rate was statistically significant (P<0.05) in all three dimensions for both the head and the tail. For the MPMI group, the displacement rate was statistically significant (P<0.05) only in the antero-posterior (head and tail) and vertical (head) dimensions. Conclusions: Buccal, palatal and midpalatal mini-implants showed some displacement (mean value <= 0.78) when submitted to force, although they are aimed to provide stable skeletal anchorage.
引用
收藏
页码:1151 / 1156
页数:6
相关论文
共 50 条
  • [21] Optimal sites for mini-implant insertion into the infrazygomatic crest according to different craniofacial morphologies: A cross-sectional cone-beam computed tomography study
    Sanchis, Carolina Rojo
    Perez-Varela, Juan Carlos
    Zamora-Martinez, Natalia
    Garcia-Sanz, Veronica
    Tarazona-Alvarez, Beatriz
    Paredes-Gallardo, Vanessa
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2025, 167 (03) : 261 - 272
  • [22] Volumetric Measurement of Root Resorption following Molar Mini-Screw Implant Intrusion Using Cone Beam Computed Tomography
    Li, Wen
    Chen, Fei
    Zhang, Feng
    Ding, Wanghui
    Ye, Qingsong
    Shi, Jiejun
    Fu, Baiping
    PLOS ONE, 2013, 8 (04):
  • [23] RETROSPECTIVE ASSESSMENT OF DENTAL IMPLANT-RELATED ANATOMICAL STRUCTURE PERFORATIONS USING CONE BEAM COMPUTED TOMOGRAPHY
    Alsharif, Shahad B.
    Bahanan, Lina
    Almutairi, Maitha
    Alshammry, Sultana
    Khalifa, Hanadi
    ANNALS OF DENTAL SPECIALTY, 2023, 11 (01): : 21 - 30
  • [24] Labial bone assessment surrounding dental implant using cone-beam computed tomography: an in vitro study
    Naitoh, Munetaka
    Hayashi, Hisashi
    Tsukamoto, Nobutaka
    Ariji, Eiichiro
    CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (08) : 970 - 974
  • [25] Assessment of mandibular posterior regional landmarks using cone-beam computed tomography in dental implant surgery
    de Souza, Lilian Azevedo
    Souza Picorelli Assis, Neuza Maria
    Ribeiro, Rosangela Almeida
    Pires Carvalho, Antonio Carlos
    Devito, Karina Lopes
    ANNALS OF ANATOMY-ANATOMISCHER ANZEIGER, 2016, 205 : 53 - 59
  • [26] A CBCT Assessment of Orthodontic Mini-Implant Placement
    Ashil, A. M.
    Sharma, Aseem
    Jose, Lijo K.
    Grover, Shubhi
    Kochar, Anuraj Singh
    Varghese, Shaji T.
    Sharma, Tanushree
    Ismail, Prabu Mahin Syed
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 : S927 - S929
  • [27] Assessment of the configuration of the mandibular canal using cone beam computed tomography
    Manfron, Ana P. Tulio
    Ditzel, Alessandra S.
    Ignacio, Sergio A.
    Fontao, Flavia N.
    Azevedo-Alanis, Luciana R.
    MINERVA STOMATOLOGICA, 2020, 69 (06): : 377 - 383
  • [28] Radiographic Assessment of Nasopalatine Canal Using Cone Beam Computed Tomography
    Al-Ghurabi, Zainab H.
    Al-Bahrani, Zainab M.
    JOURNAL OF CRANIOFACIAL SURGERY, 2020, 31 (01) : E4 - E6
  • [29] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [30] A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions
    Al-Ekrish, A. A.
    Ekram, M.
    DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) : 67 - 75