High Quality Image Reconstruction for Short Frame in Dynamic PET

被引:0
|
作者
Zhu, Wentao [1 ]
Chen, Mu [2 ]
Dong, Yun [2 ]
Bao, Jun [2 ]
Li, Hongdi [1 ]
机构
[1] UIH Amer Inc, Houston, TX 77054 USA
[2] Shanghai United Imaging, Shanghai, Peoples R China
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Low count PET studies usually suffer from high image noise and quantitative bias in reconstructed image. This is particularly significant for short frames (temporal-ROI, or T-ROI) in dynamic PET studies, which in some cases may be as short as 30 seconds or less. In this paper, we proposed a method to improve the quality of the reconstructed short frame by utilizing information from a longer acquisition time that contains the short frame. The data of the longer acquisition excluding the short frame is first sorted to perform a reconstruction. The reconstructed image is then forward projected to obtain its contribution in the data space. A second reconstruction is then executed with data from the entire long acquisition (including the short frame) and the previous contribution in the data space to estimate the activity for the short frame. Results show that the image quality and CRC-noise performance are both improved with our proposed method than the standard reconstruction with counts from the target frame only, as well as the complementary reconstruction method published earlier.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Complementary Reconstruction: Improving Image Quality in Dynamic PET Studies
    Hong, Inki
    Cho, Sanghee
    Casey, Michael
    Michel, Christian
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4327 - 4328
  • [2] Reconstruction method to combine high temporal resolution with appropriate image quality in dynamic PET angiography
    Kuehnel, Christian
    Seifert, Philipp
    Drescher, Robert
    Freesmeyer, Martin
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (13) : 2954 - 2955
  • [3] Reconstruction method to combine high temporal resolution with appropriate image quality in dynamic PET angiography
    Christian Kühnel
    Philipp Seifert
    Robert Drescher
    Martin Freesmeyer
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2020, 47 : 2954 - 2955
  • [4] Effect of high-definition PET reconstruction on FDG PET image quality
    Tomita, Yoya
    Nishida, Hiroyuki
    Kojima, Akihiro
    Tamai, Shinichi
    Yamamuro, Osamu
    Kobayashi, Toshiki
    Chen, Weiping
    Nishio, Masami
    Tamaki, Tsuneo
    Iwata, Hiroshi
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [5] An image reconstruction method for dynamic PET
    Wernick, MN
    Wang, GG
    Kao, CM
    Yap, JT
    Mukherjee, J
    Cooper, M
    Chen, CT
    [J]. 1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 1718 - 1722
  • [6] A row-action image reconstruction of short time frame for microPET dynamic study
    Vasko, A.
    Hsu, C-H
    Lin, M-C
    Hsiao, I-T
    Wieholt, C.
    Chen, C-T
    [J]. 2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2510 - 2513
  • [7] Four-dimensional (4D) image reconstruction strategies in dynamic PET: Beyond conventional independent frame reconstruction
    Rahmim, Arman
    Tang, Jing
    Zaidi, Habib
    [J]. MEDICAL PHYSICS, 2009, 36 (08) : 3654 - 3670
  • [8] Statistical dynamic image reconstruction in state-of-the-art high-resolution PET
    Rahmim, A
    Cheng, JC
    Blinder, S
    Camborde, ML
    Sossi, V
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (20): : 4887 - 4912
  • [9] Image Quality with Time of Flight Reconstruction of PET Images
    Savini, B. F.
    Bird, N.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S181 - S182
  • [10] PEM-PET Image Reconstruction in a Clinically-Relevant Time Frame
    Smith, Mark F.
    Raylman, Raymond R.
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1792 - 1796