Statistical dynamic image reconstruction in state-of-the-art high-resolution PET

被引:108
|
作者
Rahmim, A [1 ]
Cheng, JC
Blinder, S
Camborde, ML
Sossi, V
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiol, Baltimore, MD 21287 USA
[2] Univ British Columbia, Dept Phys & Astron, Vancouver, BC V6T 1Z1, Canada
[3] Pacific Parkinsons Res Ctr, Vancouver, BC V6T 1Z1, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2005年 / 50卷 / 20期
关键词
D O I
10.1088/0031-9155/50/20/010
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Modem high-resolution PET is now more than ever in need of scrutiny into the nature and limitations of the imaging modality itself as well as image reconstruction techniques. In this work, we have reviewed, analysed and addressed the following three considerations within the particular context of state-of-the-art dynamic PET imaging: (i) the typical average numbers of events per line-of-response (LOR) are now (much) less than unity, (ii) due to the physical and biological decay of the activity distribution, one requires robust and efficient reconstruction algorithms applicable to a wide range of statistics and (iii) the computational considerations in dynamic imaging are much enhanced (i.e., more frames to be stored and reconstructed). Within the framework of statistical image reconstruction, we have argued theoretically and shown experimentally that the sinogram non-negativity constraint (when using the delayed-coincidence and/or scatter-subtraction techniques) is especially expected to result in an overestimation bias. Subsequently, two schemes are considered: (a) subtraction techniques in which an image non-negativity constraint has been imposed and (b) implementation of random and scatter estimates inside the reconstruction algorithms, thus enabling direct processing of Poisson-distributed prompts. Both techniques are able to remove the aforementioned bias, while the latter, being better conditioned theoretically, is able to exhibit superior noise characteristics. We have also elaborated upon and verified the applicability of the accelerated list-mode image reconstruction method as a powerful solution for accurate, robust and efficient dynamic reconstructions of high-resolution data (as well as a number of additional benefits in the context of state-of-the-art PET).
引用
收藏
页码:4887 / 4912
页数:26
相关论文
共 50 条
  • [1] STATE-OF-THE-ART ON HIGH-RESOLUTION CARS
    SCHROTTER, HW
    BOQUILLON, JP
    [J]. VIBRATIONAL SPECTRA AND STRUCTURE, VOL 17 B: RAMAN SPECTROSCOPY SIXTY YEARS ON, 1989, 17 : 1 - 14
  • [2] Impact of a high-resolution reconstruction using state-of-the-art PET/CT on intra-thoracic lymph node staging
    Koopman, Danielle
    van Dalen, J. A.
    Knollema, S.
    Slump, Cornelis
    Jager, Pieter
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [3] The High Dynamic Reconstruction of High-resolution Image Based on MapReduce
    Feng, Houyong
    Liu, Peizhi
    Mu, Nan
    Wang, Jinhua
    [J]. PROCEEDINGS OF 2017 IEEE INTERNATIONAL CONFERENCE ON UNMANNED SYSTEMS (ICUS), 2017, : 454 - 457
  • [4] State-of-the-art of small animal imaging with high-resolution SPECT
    Nikolaus, S
    Wirrwar, A
    Antke, C
    Kley, K
    Müller, HW
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2005, 44 (06): : 257 - 266
  • [5] Online detector response calculations for high-resolution PET image reconstruction
    Pratx, Guillem
    Levin, Craig
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (13): : 4023 - 4040
  • [6] Terahertz nonstationary high-resolution spectroscopy: state-of-the-art and trends of development
    Vaks, Vladimir l.
    Domracheva, Elena G.
    Chernyaeva, Mariya B.
    Anfertev, Vladimir A.
    Yablokov, Anton A.
    [J]. JOURNAL OF OPTICAL TECHNOLOGY, 2024, 91 (01) : 23 - 28
  • [7] Multi-resolution image reconstruction for a high-resolution small animal PET device
    Clinthorne, NH
    Park, S
    Rogers, WL
    Chiao, PC
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 1997 - 2001
  • [8] Detector response models for statistical iterative image reconstruction in high resolution PET
    Selivanov, V.V.
    Picard, Y.
    Cadorette, J.
    Rodrigue, S.
    Lecomte, R.
    [J]. IEEE Transactions on Nuclear Science, 2000, 47 (3 III) : 1168 - 1175
  • [9] Detector response models for statistical iterative image reconstruction in high resolution PET
    Selivanov, VV
    Picard, Y
    Cadorette, J
    Rodrigue, S
    Lecomte, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2000, 47 (03) : 1168 - 1175
  • [10] High-resolution image reconstruction with multisensors
    Bose, NK
    Boo, KJ
    [J]. INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 1998, 9 (04) : 294 - 304