Comparison of the Measured Stem Leakage Correction Factor for an Ionization Chamber in Air to the Monte Carlo Simulation

被引:2
|
作者
Kweon, Dae Cheol [1 ]
Lee, Jae-Seung [2 ,3 ]
Goo, Eun-Hoe [3 ,4 ]
Kim, Moon-Jib [3 ]
Jung, Jae-Eun [5 ]
Chung, Woon-Kwan [6 ]
Dong, Kyung-Rae [6 ,7 ]
Lee, Jin-Kook [8 ]
Park, Cheol-Woo [9 ]
Im, In-Chul [10 ]
机构
[1] Shin Heung Coll Univ, Dept Radiol Sci, Uijongbu 480701, South Korea
[2] Good Samaritan Hosp, Dept Radiat Oncol, Pohang 791704, South Korea
[3] Soonchunhyang Univ, Dept Phys, Asan 336745, South Korea
[4] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[5] Sahm Yook Seoul Med Ctr, Dept Biomed Engn, Seoul 130711, South Korea
[6] Chosun Univ, Dept Nucl Engn, Kwangju 501759, South Korea
[7] Gwangju Hlth Coll Univ, Dept Radiol Technol, Kwangju 501701, South Korea
[8] Kyoungpook Natl Univ Hosp, Dept Radiat Oncol, Daegoo 702210, South Korea
[9] Dongeui Inst Technol, Dept Radiol Technol, Pusan 614715, South Korea
[10] Dong Eui Univ, Dept Radiol Sci, Pusan 614714, South Korea
关键词
Stem leakage; Ionization chamber; Monte Carlo simulation; Build-up cap; Measurement; ION-CHAMBER; PHOTON; BEAM; RADIOTHERAPY; CODE;
D O I
10.3938/jkps.58.1184
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Stem leakage arises as a consequence of the direct irradiation of a sensitive volume, and the metal stem of the ionization chamber, and the chamber response is likely to be affected by the photons scattered from the chamber stem. These interactions contribute to the apparent measured exposure. Build-up caps were used in the exposure measurement. The stem leakages of PTW model TM 30013 and TM 31010 (vented to air, sensitive volume: 0.6 and 0.125 cm(3)) ionization chambers were measured. High-energy photons generated by a linear accelerator and the sensitive volume of the ionization chamber were measured to examine the stem leakage of the ionization chamber and were compared with the results of a Monte Carlo simulation. As a result, the electrons ejected from the metal stem could were found to collect at the central electrode. The stem leakage correction factor (k(stem, leak)) decreased with increasing photon energy and sensitive volume. The stern of the ionization chamber that scattered photons made the largest contribution to the exposure dose, showing a dependency on the energy of photons and the sensitive volume of the ionization chamber. The stem leakage correction factors were determined within 0.4% according to the length of the stem exposed in repeated measurements for various radiation fields.
引用
收藏
页码:1184 / 1194
页数:11
相关论文
共 50 条
  • [41] Monte Carlo calculated ionization chamber correction factors in clinical proton beams - deriving uncertainties from published data
    Baumann, Kilian-Simon
    Goma, Carles
    Wulff, Joerg
    Kretschmer, Jana
    Zink, Klemens
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 113
  • [42] Monte Carlo and Water Calorimetric Determination of Ionization Chamber Correction Factors for Medium Energy X-Ray Beams
    Bancheri, J.
    Ketelhut, S.
    Bueermann, L.
    Seuntjens, J.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E816 - E816
  • [43] INVESTIGATION OF ENERGY RESPONSE OF GERMANIUM DETECTORS AND CORRECTION OF MEASURED SPECTRA BY MEANS OF MONTE-CARLO SIMULATION
    CHAN, HP
    CHEN, CT
    DOI, K
    FEWELL, TR
    SHUPING, RE
    [J]. MEDICAL PHYSICS, 1982, 9 (04) : 633 - 633
  • [44] INVESTIGATION OF ENERGY RESPONSES OF GERMANIUM DETECTORS AND CORRECTION OF MEASURED SPECTRA BY MEANS OF MONTE-CARLO SIMULATION
    CHAN, HP
    CHEN, CT
    DOI, K
    FEWELL, TR
    SHUPING, RE
    [J]. RADIATION RESEARCH, 1984, 99 (03) : 443 - 464
  • [45] A comparison of Monte Carlo methods for neutron leakage at assembly level
    Dorval, E.
    [J]. ANNALS OF NUCLEAR ENERGY, 2016, 87 : 591 - 600
  • [46] Monte Carlo simulation of portal detectors of a steel factory. Comparison of measured and simulated response
    Takoudis, G.
    Xanthos, S.
    Clouvas, A.
    Antonopoulos-Domis, M.
    Potiriadis, C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 396 - 399
  • [47] Beam hardening correction based on Monte Carlo simulation
    Zeng, G
    Yu, ZQ
    Yan, YL
    [J]. HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (02): : 178 - 182
  • [48] On a simple and accurate quantum correction for Monte Carlo simulation
    F. M. Bufler
    R. Hudé
    A. Erlebach
    [J]. Journal of Computational Electronics, 2006, 5 : 467 - 469
  • [49] MONTE-CARLO SIMULATION OF MATRIX CORRECTION EFFECTS
    HOWARTH, RJ
    [J]. ANALYST, 1973, 98 (1172) : 777 - 781
  • [50] On a simple and accurate quantum correction for Monte Carlo simulation
    Bufler, F. M.
    Hude, R.
    Erlebach, A.
    [J]. JOURNAL OF COMPUTATIONAL ELECTRONICS, 2006, 5 (04) : 467 - 469