Sequential based analysis of Intima-Media Thickness (IMT) in common carotid artery studies

被引:13
|
作者
Haller, C. [1 ]
Schulz, Janina [3 ]
Schmidt-Trucksaess, A. [2 ]
Burkardt, H. [3 ]
Schmitz, D. [1 ]
Dickhuth, H. -H. [1 ]
Sandrock, M. [1 ]
机构
[1] Freiburg Univ Hosp, Ctr Internal Med, Dept Rehabilitat & Preventat Sports Med, D-79106 Freiburg, Germany
[2] Tech Univ Munich, Dept Sports Med, D-80106 Munich, Germany
[3] Univ Freiburg, Inst Comp Sci, Chair Pattern Recognit & Image Anal, D-79110 Freiburg, Germany
关键词
IMT; Risk factors; CAD;
D O I
10.1016/j.atherosclerosis.2007.07.017
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Carotid Intima-Media Thickness (IMT) is used widely to assess an individual's risk of myocardial infarction and stroke. Although significant associations have been showed, IMT as used in major studies does not improve prediction of cardiovascular events much compared to traditional risk factors. Therefore, a new approach to IMT-measurements is sought-after by examining the wall structure continuously throughout several heart cycles. Materials and methods: Computerized single-image analysis (IA) and sequential analysis (SA) were used to assess latter's capability in predicting risk of cardiovascular disease and to compare both. Healthy subjects (mean +/- S. D., age 46.1 +/- 5.6 years, n = 490) were compared with subjects suffering from confirmed coronary artery disease (CAD) (mean +/- S. D., age 47.3 +/- 6.2 years, n = 51). Results: SA could differentiate between both groups better then single IA, especially when looking at the maximal and mean IMT-values (SA <-> IA, p < 0.01 <-> p < 0.05). The area under the curve (AUC) for maximal and mean IMT was greater for sequences then for single images as well. Discussion: Due to our findings sequential analysis can offer an extensive and complete examination of the carotid wall with a maximal reduction of bias. Commonly used IA may disguise vascular conditions and therefore the patient's risk, since IMT-values, as proven with SA, seems to usually be higher. Therefore, the need for further studies arises, examining if and to what extend common IMT-studies underestimate differences between groups. (C) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:E203 / E209
页数:7
相关论文
共 50 条
  • [21] Reproducibility of measurements of intima-media thickness and distensibility in the common carotid artery
    Kanters, SDJM
    Elgersma, OEH
    Banga, JD
    van Leeuwen, MS
    Algra, A
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 16 (01) : 28 - 35
  • [22] Detection of Intima-media Thickness in Common Carotid Artery on Ultrasound Image
    He, Xing-wu
    INFORMATION ENGINEERING FOR MECHANICS AND MATERIALS RESEARCH, 2013, 422 : 165 - 171
  • [23] The value of common carotid artery intima-media thickness in evaluating atherosclerosis
    Tarjan, J.
    Vassanyi, I.
    Voros, B.
    EUROPEAN HEART JOURNAL, 2007, 28 : 113 - 113
  • [24] Common carotid artery intima-media thickness and ischaemic stroke severity
    Heliopoulos, I.
    Hatzidounas, T.
    Papaioakim, M.
    Vadikolias, K.
    Terzoudi, A.
    Artemis, D.
    Piperidou, C.
    JOURNAL OF NEUROLOGY, 2006, 253 : 138 - 138
  • [25] Psoriasis and carotid artery intima-media thickness
    Raj, R. Pavan
    Hazarika, D.
    BRITISH JOURNAL OF DERMATOLOGY, 2016, 175 : 48 - 48
  • [26] Snoring and Carotid Artery Intima-Media Thickness
    Deeb, Robert
    Judge, Paul
    Peterson, Ed
    Lin, Judith C.
    Yaremchuk, Kathleen
    LARYNGOSCOPE, 2014, 124 (06): : 1486 - 1491
  • [27] Relationship between intima-media thickness in the common carotid artery and atherosclerosis in the carotid bifurcation
    Rosfors, S
    Hallerstam, S
    Jensen-Urstad, K
    Zetterling, M
    Carlström, C
    STROKE, 1998, 29 (07) : 1378 - 1382
  • [28] Computationally efficient algorithm for the estimation of the intima-media thickness of the common carotid artery
    Turcza, Pawel
    Zielinski, Tomasz P.
    Kwater, Aleksander
    Grodzicki, Tomasz
    ICCS 2010 - INTERNATIONAL CONFERENCE ON COMPUTATIONAL SCIENCE, PROCEEDINGS, 2010, 1 (01): : 465 - 474
  • [29] Plasma leptin is independently associated with the intima-media thickness of the common carotid artery
    M Ciccone
    R Vettor
    N Pannacciulli
    A Minenna
    M Bellacicco
    P Rizzon
    R Giorgino
    G De Pergola
    International Journal of Obesity, 2001, 25 : 805 - 810
  • [30] Increased common carotid artery intima-media thickness in Takayasu's Arteritis
    Sivakumar, Sanjeev
    Rajappa, Sivakumar M.
    ANNALS OF NEUROLOGY, 2006, 60 : S89 - S89