Size and Velocity Characteristics of Droplets Generated by Thin Steel Slab Continuous Casting Secondary Cooling Air-Mist Nozzles

被引:25
|
作者
Minchaca M, J. I.
Castillejos E, A. H.
Acosta G, F. A.
机构
[1] Centre for Research and Advanced Studies, CINVESTAV - Unidad Saltillo, Coahuila
关键词
HEAT-TRANSFER; WATER; DROPS;
D O I
10.1007/s11663-011-9501-x
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Direct spray impingement of high temperature surfaces, 1473 K to 973 K (1200 A degrees C to 700 A degrees C), plays a critical role in the secondary cooling of continuously cast thin steel slabs. It is known that the spray parameters affecting the local heat flux are the water impact flux w as well as the droplet velocity and size. However, few works have been done to characterize the last two parameters in the case of dense mists (i.e., mists with w in the range of 2 to 90 L/m(2)s). This makes it difficult to rationalize how the nozzle type and its operating conditions must be selected to control the cooling process. In the present study, particle/droplet image analysis was used to determine the droplet size and velocity distributions simultaneously at various locations along the major axis of the mist cross section at a distance where the steel strand would stand. The measurements were carried out at room temperature for two standard commercial air-assisted nozzles of fan-discharge type operating over a broad range of conditions of practical interest. To achieve statistically meaningful samples, at least 6000 drops were analyzed at each location. Measuring the droplet size revealed that the number and volume frequency distributions were fitted satisfactorily by the respective log-normal and Nukiyama-Tanasawa distributions. The correlation of the parameters of the distribution functions with the water- and air-nozzle pressures allowed for reasonable estimation of the mean values of the size of the droplets generated. The ensemble of measurements across the mist axis showed that the relationship between the droplet velocity and the diameter exhibited a weak positive correlation. Additionally, increasing the water flow rate at constant air pressure caused a decrease in the proportion of the water volume made of finer droplets, whereas the volume proportion of faster droplets augmented until the water flow reached a certain value, after which it decreased. Diminishing the air-to-water flow rates ratio, particularly below 10, resulted in mists of bigger and slower droplets with low impinging Weber numbers. However, increasing the air pressure maintaining a constant water flow rate caused a greater proportion of finer and faster drops with Weber numbers greater than 80, which suggests an increased probability of wet drop contact with a hot surface that would intensify heat extraction.
引用
收藏
页码:500 / 515
页数:16
相关论文
共 23 条
  • [21] Study on Secondary Phase Precipitation Behavior of Ship Plate Steel Slab Under Different Cooling Rates in Continuous Casting Process
    Wang, Huisheng
    Liu, Qing
    Tao, Biao
    Wu, Jun
    Li, Ming
    Guan, Min
    Huang, Weili
    TMS 2024 153RD ANNUAL MEETING & EXHIBITION: SUPPLEMENTAL PROCEEDINGS, 2024, : 1104 - 1116
  • [22] Experimental Study on the Characteristics and High-Temperature Heat Transfer of Secondary Cooling Nozzle for High-Efficiency Slab Continuous Casting Process
    Li, Jia-kun
    Xu, Rong-jun
    Lv, Ming
    Sun, Xiong-bo
    Gao, Qi
    Du, Zhong-ze
    Zhang, Zhao-hui
    STEEL RESEARCH INTERNATIONAL, 2024, 95 (10)
  • [23] Two-phase thermo-mechanical and macrosegregation modelling of binary alloys solidification with emphasis on the secondary cooling stage of steel slab continuous casting processes
    Fachinotti, Victor D.
    Le Corre, Steven
    Triolet, Nicolas
    Bobadilla, Manuel
    Bellet, Michel
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2006, 67 (10) : 1341 - 1384