Autoantibody testing by enzyme-linked immunosorbent assay-a case in which the solid phase decides on success and failure

被引:8
|
作者
Deutschmann, Claudia [1 ]
Roggenbuck, Dirk [1 ,2 ]
Schierack, Peter [1 ]
Roediger, Stefan [1 ,2 ]
机构
[1] Brandenburg Univ Technol Cottbus Senftenberg, Fac Environm & Nat Sci, Inst Biotechnol, Univ Pl 1, D-01968 Senftenberg, Germany
[2] Univ Potsdam, Joint Fac Brandenburg Univ Technol Cottbus Senfte, Fac Hlth Sci, Brandenburg Med Sch Theodor Fontane, Senftenberg, Germany
关键词
Biochemistry; Coatings; Surface chemistry; Immunology; Proteins; Laboratory medicine; Clinical research; Enzyme-linked immunosorbent assay; Biomarker discovery; Reproducibility; Solid-phase; Autoantibody; PROTEIN ADSORPTION; PLATELET-ADHESION; ELISA; STANDARDS; REPRODUCIBILITY; DIAGNOSIS;
D O I
10.1016/j.heliyon.2020.e03270
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: The enzyme-linked immunosorbent assay (ELISA) is an indispensable tool for clinical diagnostics to identify or differentiate diseases such as autoimmune illnesses, but also to monitor their progression or control the efficacy of drugs. One use case of ELISA is to differentiate between different states (e.g. healthy vs. diseased). Another goal is to quantitatively assess the biomarker in question, like autoantibodies. Thus, the ELISA technology is used for the discovery and verification of new autoantibodies, too. Of key interest, however, is the development of immunoassays for the sensitive and specific detection of such biomarkers at early disease stages. Therefore, users have to deal with many parameters, such as buffer systems or antigen-autoantibody interactions, to successfully establish an ELISA. Often, fine-tuning like testing of several blocking substances is performed to yield high signal-to-noise ratios. Methods: We developed an ELISA to detect IgA and IgG autoantibodies against chitinase-3-like protein 1 (CHI3L1), a newly identified autoantigen in inflammatory bowel disease (IBD), in the serum of control and disease groups (n = 23, respectively). Microwell plates with different surface modifications (PolySorp and MaxiSorp coating) were tested to detect reproducibility problems. Results: We found a significant impact of the surface properties of the microwell plates. IgA antibody reactivity was significantly lower, since it was in the range of background noise, when measured on MaxiSorp coated plates (p < 0.0001). The IgG antibody reactivity did not differ on the diverse plates, but the plate surface had a significant influence on the test result (p = 0.0005). Conclusion: With this report, we want to draw readers' attention to the properties of solid phases and their effects on the detection of autoantibodies by ELISA. We want to sensitize the reader to the fact that the choice of the wrong plate can lead to a false negative test result, which in turn has serious consequences for the discovery of autoantibodies.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR MET-ENKEPHALIN USING UNCONJUGATED ENKEPHALIN AS A SOLID-PHASE ANTIGEN
    TAKESUE, Y
    NAKASEKOZAKI, Y
    ANALYTICAL BIOCHEMISTRY, 1985, 146 (01) : 35 - 39
  • [32] Automated enzyme-linked immunosorbent assay for point-of-care COVID-19 testing
    Baldo, Thaisa A.
    Ataide, Vanessa N.
    Park, Joowon
    Panraksa, Yosita
    Martinez, Brandaise
    Anderson, Loran B. R.
    Malsick, Lauren E.
    Gallichotte, Emily N.
    Ebel, Gregory D.
    Geiss, Brian J.
    Dandy, David S.
    Paixao, Thiago R. L. C.
    Henry, Charles S.
    ELECTROCHIMICA ACTA, 2024, 497
  • [33] Enzyme-linked immunosorbent assay (ELISA) and indirect immunofluorescence testing in a bullous pemphigoid and pemphigoid gestationis
    Barnadas, Maria A.
    Victoria Rubiales, Ma
    Jose Gonzalez, Ma
    Puig, Luis
    Garcia, Pilar
    Baselga, Eulalia
    Pujol, Ramon
    Alomar, Agustin
    Gelpi, Carmen
    INTERNATIONAL JOURNAL OF DERMATOLOGY, 2008, 47 (12) : 1245 - 1249
  • [34] A SOLID-PHASE, ENZYME-LINKED IMMUNOSORBENT-ASSAY FOR A HUMAN-LUNG TUMOR-ASSOCIATED ANTIGEN
    BRAATZ, JA
    HUA, DT
    PRINCLER, GL
    JOURNAL OF THE NATIONAL CANCER INSTITUTE, 1984, 72 (04) : 841 - 846
  • [35] PRESERVATION AND COMPARATIVE USE OF POLYSTYRENE BEADS AND PLATES FOR ENZYME-LINKED IMMUNOSORBENT-ASSAY TESTING
    HSU, HT
    SIMIONE, FP
    PHYTOPATHOLOGY, 1981, 71 (02) : 227 - 227
  • [36] Identification of ovarian antibodies by immunofluorescence, enzyme-linked immunosorbent assay or immunoblotting in premature ovarian failure
    Wheatcroft, NJ
    Salt, C
    Milford-Ward, A
    Cooke, ID
    Weetman, AP
    HUMAN REPRODUCTION, 1997, 12 (12) : 2617 - 2622
  • [37] An enzyme-linked immunosorbent assay for the estimation of fungal biomass during solid-state fermentation
    Dubey, AK
    Suresh, C
    Kumar, SU
    Karanth, NG
    APPLIED MICROBIOLOGY AND BIOTECHNOLOGY, 1998, 50 (03) : 299 - 302
  • [38] An enzyme-linked immunosorbent assay for the estimation of fungal biomass during solid-state fermentation
    A. K. Dubey
    C. Suresh
    S. Umesh Kumar
    N. G. Karanth
    Applied Microbiology and Biotechnology, 1998, 50 : 299 - 302
  • [39] A SIMPLE WASHING TECHNIQUE FOR SOLID-PHASE RADIOIMMUNOASSAYS AND ENZYME-LINKED IMMUNOSORBENT ASSAYS
    PARK, H
    JOURNAL OF CLINICAL PATHOLOGY, 1981, 34 (11) : 1309 - 1310
  • [40] Development of Tubing-based Stationary Liquid-phase Enzyme-linked Immunosorbent Assay
    Soonil Kwon
    Suk-Jung Choi
    BioChip Journal, 2019, 13 : 174 - 181