Adaptive distance protection for grid-connected wind farms based on optimal quadrilateral characteristics

被引:4
|
作者
George, Sujo P. [1 ]
Ashok, S. [1 ]
机构
[1] Natl Inst Technol Calicut, Elect Engn Dept, Kozhikode, Kerala, India
关键词
Adaptive relay settings; Distributed power generation; Power system protection; Quadrilateral distance relays; Trip boundaries; Wind farms; RELAYING SCHEME; FAULT; MACHINE;
D O I
10.1016/j.compeleceng.2021.107300
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
Wind farms are generally connected to a power grid through transmission lines. The length of the transmission line depends on the rated capacity and the location of the wind farms. The fault level of the grid to which the wind farm is connected may change as the source impedance varies based on the number of wind generators (WGs) in service. This study shows that the distance relays in wind-integrated substations with conventional settings mal-operate during fault intervals depending on the operating conditions of the wind farm. The generalized characteristics of the distance relays require modification under such circumstances. In this work, an adaptive protection scheme is proposed to calculate the optimal settings of the quadrilateral distance relays according to variations in wind-power penetration. The algorithm is then validated through case studies in the laboratory using the IEEE 30-bus test system, a typical wind-integrated substation, and an experimental setup.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Power quality assessment of grid-connected wind farms considering regulations in turkey
    Kocatepe, Celal
    Inan, Asian
    Arikan, Oktay
    Yumurtaci, Recep
    Kekezoglu, Bedri
    Baysal, Mustafa
    Bozkurt, Altug
    Akkaya, Yener
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (09): : 2553 - 2561
  • [22] Coordination of Reactive Power in Grid-Connected Wind Farms for Voltage Stability Enhancement
    Kumar, Seshadri Sravan, V
    Reddy, Krishna K.
    Thukaram, D.
    2015 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, 2015,
  • [23] Analysis on the influence of an SVG on the stability of AC grid-connected offshore wind farms
    Chen H.
    Xiong X.
    Yu H.
    Li Y.
    Han Y.
    Sun H.
    Duan Y.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2022, 50 (19): : 119 - 129
  • [24] Assessment on operational flexibility of power grid with grid-connected large-scale wind farms
    Department of Electrical Engineering and Applied Electronic Technology, Tsinghua University, Haidian District,, Beijing
    100084, China
    不详
    100192, China
    Dianwang Jishu, 6 (1672-1678):
  • [25] Economic Assessment of Large Grid-connected Wind Farms——Avoided Cost Method
    魏婕
    郭元
    顾树华
    Tsinghua Science and Technology, 1999, (01) : 73 - 76
  • [26] Increase of fault ride-through capability for the grid-connected wind farms
    Ko, H. S.
    Jatskevich, J.
    Dumont, G. A.
    Moshref, A.
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 718 - +
  • [27] Reactive power control of grid-connected wind farm based on adaptive dynamic programming
    Tang, Yufei
    He, Haibo
    Ni, Zhen
    Wen, Jinyu
    Sui, Xianchao
    NEUROCOMPUTING, 2014, 125 : 125 - 133
  • [28] Adaptive PID Control Strategy for Grid-connected Based on DRNN Inverter of Wind Turbine
    Du, Fuyin
    PROCEEDINGS OF THE 14TH YOUTH CONFERENCE ON COMMUNICATION, 2009, : 863 - 866
  • [29] Smart Protection System for Microgrids with Grid-Connected and Islanded Capabilities Based on an Adaptive Algorithm
    Sampaio, Felipe Carvalho
    Tofoli, Fernando Lessa
    Melo, Lucas Silveira
    Barroso, Giovanni Cordeiro
    Sampaio, Raimundo Furtado
    Leao, Ruth Pastora Saraiva
    ENERGIES, 2023, 16 (05)
  • [30] Study on transient characteristics of grid-connected wind power generators
    Zhang, Yan
    Lin, Li
    Yang, Yihan
    2007 CONFERENCE PROCEEDINGS IPEC, VOLS 1-3, 2007, : 520 - 525