Support vector machine-based assessment of the T-wave morphology improves long QT syndrome diagnosis

被引:21
|
作者
Hermans, Ben J. M. [1 ,2 ,3 ]
Stoks, Job [1 ,2 ,4 ]
Bennis, Frank C. [1 ,5 ]
Vink, Arja S. [6 ]
Garde, Ainara [7 ]
Wilde, Arthur A. M. [6 ]
Pison, Laurent [3 ]
Postema, Pieter G. [6 ]
Delhaas, Tammo [1 ,2 ]
机构
[1] Maastricht Univ, Dept Biomed Engn, POB 616, NL-6200 MD Maastricht, Netherlands
[2] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, POB 616, NL-6200 MD Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Cardiol, POB 5800, NL-6202 AZ Maastricht, Netherlands
[4] Univ Twente, MIRA Inst Biomed Technol & Tech Med, POB 217, NL-7500 AE Enschede, Netherlands
[5] Maastricht Univ, MHeNS Sch Mental Hlth & Neurosci, POB 616, NL-6200 MD Maastricht, Netherlands
[6] Acad Med Ctr, Heart Ctr, Dept Clin & Expt Cardiol, POB 22660, NL-1100 DD Amsterdam, Netherlands
[7] Univ Twente, Fac EEMCS, Dept Biomed Signals & Syst, POB 217, NL-7500 AE Enschede, Netherlands
来源
EUROPACE | 2018年 / 20卷
关键词
QT-interval; T-wave; Morphology; Long QT syndrome; Machine learning; INTERVAL; REGULARIZATION;
D O I
10.1093/europace/euy243
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Diagnosing long QT syndrome (LQTS) is challenging due to a considerable overlap of the QTc-interval between LQTS patients and healthy controls. The aim of this study was to investigate the added value of T-wave morphology markers obtained from 12-lead electrocardiograms (ECGs) in diagnosing LQTS in a large cohort of genepositive LQTS patients and gene-negative family members using a support vector machine. Methods and results A retrospective study was performed including 688 digital 12-lead ECGs recorded from genotype-positive LQTS patients and genotype-negative relatives at their first visit. Two models were trained and tested equally: a baseline model with age, gender, RR-interval, QT-interval, and QTc-intervals as inputs and an extended model including morphology features as well. The best performing baseline model showed an area under the receiver-operating characteristic curve (AUC) of 0.821, whereas the extended model showed an AUC of 0.901. Sensitivity and specificity at the maximal Youden's indexes changed from 0.694 and 0.829 with the baseline model to 0.820 and 0.861 with the extended model. Compared with clinically used QTc-interval cut-off values (> 480 ms), the extended model showed a major drop in false negative classifications of LQTS patients. Conclusion The support vector machine-based extended model with T-wave morphology markers resulted in a major rise in sensitivity and specificity at the maximal Youden's index. From this, it can be concluded that T-wave morphology assessment has an added value in the diagnosis of LQTS.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 50 条
  • [41] P- and T-wave Delineation in ECG Signals using Support Vector Machine
    Saini, Indu
    Singh, Dilbag
    Khosla, Arun
    IETE JOURNAL OF RESEARCH, 2013, 59 (05) : 615 - 623
  • [42] Automated T-wave analysis can differentiate acquired QT prolongation from congenital long QT syndrome
    Sugrue, Alan
    Noseworthy, Peter A.
    Kremen, Vaclav
    Bos, J. Martijn
    Qiang, Bo
    Rohatgi, Ram K.
    Sapir, Yehu
    Attia, Zachi I.
    Brady, Peter
    Caraballo, Pedro J.
    Asirvatham, Samuel J.
    Friedman, Paul A.
    Ackerman, Michael J.
    ANNALS OF NONINVASIVE ELECTROCARDIOLOGY, 2017, 22 (06)
  • [43] Support Vector Machine-Based Instantaneous Presence Detection for Continuous Wave Radar Systems
    Schellenberger, Sven
    Shi, Kilin
    Steigleder, Tobias
    Michler, Fabian
    Lurz, Fabian
    Weigel, Robert
    Koelpin, Alexander
    2018 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC), 2018, : 1465 - 1467
  • [44] Prolonged QT Interval With T-Wave Alternans: Electrocardiogram-Based Differential Diagnosis
    Hanna, Elias B.
    Ahmed, Jameel
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2013, 346 (02): : 128 - 128
  • [46] MACROSCOPIC T-WAVE ALTERNANS PRECEDES CARDIAC ARREST IN UNDIAGNOSED CONGENITAL LONG QT SYNDROME
    Lee, Sun Yong
    Lee, Byron K.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 2865 - 2865
  • [47] Abolition of T-wave alternans in a case of congenital long-QT syndrome with atrial pacing
    Nair, Krishna Kumar Mohanan
    Namboodiri, Narayanan
    Kevadiya, Hiren
    Valaparambil, Ajitkumar
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (12) : 1718 - 1720
  • [48] An unusual resolution of T-wave oversensing in an implantable cardioverter defibrillator in a child with long QT syndrome
    Cohen, Mitchell I.
    Anagnostopoulos, Petros V.
    Papez, Andrew
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2009, 25 (03) : 235 - 238
  • [49] ELECTROCARDIOGRAPHIC T-WAVE PATTERNS IN GENETICALLY DISTINCT FORMS OF THE HEREDITARY LONG-QT SYNDROME
    MOSS, AJ
    ZAREBA, W
    BENHORIN, J
    LOCATI, EH
    HALL, WJ
    ROBINSON, JL
    SCHWARTZ, PJ
    TOWBIN, JA
    VINCENT, GM
    LEHMANN, MH
    KEATING, MT
    MACCLUER, JW
    TIMOTHY, KW
    CIRCULATION, 1995, 92 (08) : 3264 - 3264
  • [50] Monophasic action potential recordings during T-wave alternans in congenital long QT syndrome
    Shimizu, W
    Yamada, K
    Arakaki, Y
    Kamiya, T
    Shimomura, K