Adaptive dual-exposure fusion-based transport of intensity phase microscopy

被引:4
|
作者
Hu, Junbao [1 ]
Kong, Yan [1 ]
Jiang, Zhilong [1 ]
Xue, Liang [2 ]
Liu, Fei [3 ,4 ]
Liu, Cheng [1 ,5 ]
Wang, Shouyu [1 ,4 ]
机构
[1] Jiangnan Univ, Sch Sci, Dept Optoelect Informat Sci & Technol, Computat Opt Lab, Wuxi 214122, Jiangsu, Peoples R China
[2] Shanghai Univ Elect Power, Coll Elect & Informat Engn, Shanghai 200090, Peoples R China
[3] Nanjing Agr Univ, Joint Int Res Lab Anim Hlth & Food Safety, Minist Educ, Nanjing 210095, Jiangsu, Peoples R China
[4] Nanjing Agr Univ, Single Mol Nanometry Lab Sinmolab, Nanjing 210095, Jiangsu, Peoples R China
[5] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai 201800, Peoples R China
基金
中国国家自然科学基金;
关键词
ANGULAR SPECTRUM METHOD; EQUATION; RETRIEVAL; AMPLITUDE; RECONSTRUCTION; FIELD;
D O I
10.1364/AO.57.007249
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Via the transport of intensity phase microscopy, quantitative phase can be retrieved directly from captured multi-focal intensities. The accuracy of the retrieved phases depends highly on the quality of the recorded images; therefore, the exposure time should be carefully chosen for high-quality intensity captures. However, it is difficult to record well-exposure intensities to maintain rather a high signal to noise ratio and to avoid over-exposure due to the complex samples. In order to simplify the exposure determination, here the adaptive dual-exposure fusion-based transport of intensity phase microscopy is proposed: with captured short- and long-exposure images, the well-exposure multi-focal images can be numerically reconstructed, and then high-accurate phase can be computed from these reconstructed intensities. With both simulations and experiments provided in this paper, it is proved that the adaptive dual-exposure fusion-based transport of intensity phase microscopy not only provides numerically reconstructed well-exposure image with simple operation and fast speed but also extracts highly accurate retrieved phase. Moreover, the exposure time selection scope of the proposed method is much wider than that based on single exposure, and even though there is an over-exposure region in the long-exposure image, a well-exposure image can still be reconstructed with high precision. Considering its advantages of high accuracy, fast speed, simple operation, and wide application scope, the proposed technique can be adopted as quantitative phase microscopy for high-quality observations and measurements. (C) 2018 Optical Society of America
引用
收藏
页码:7249 / 7258
页数:10
相关论文
共 50 条
  • [1] Adaptive Calibration for Fusion-based Wireless Sensor Networks
    Tan, Rui
    Xing, Guoliang
    Liu, Xue
    Yao, Jianguo
    Yuan, Zhaohui
    [J]. 2010 PROCEEDINGS IEEE INFOCOM, 2010,
  • [2] sPhaseStation: a whole slide quantitative phase imaging system based on dual-view transport of intensity phase microscopy
    Zhu, Lin
    Xiao, Zhibo
    Chen, Chao
    Sun, Aihui
    He, Xiaoliang
    Jiang, Zhilong
    Kong, Yan
    Xue, Liang
    Liu, Cheng
    Wang, Shouyu
    [J]. APPLIED OPTICS, 2023, 62 (08) : 1886 - 1894
  • [3] Image fusion-based adaptive regularization for image expansion
    Shin, JH
    Yoon, JS
    Paik, JK
    [J]. IMAGE AND VIDEO COMMUNICATIONS AND PROCESSING 2000, 2000, 3974 : 1040 - 1048
  • [4] Dual-view transport of intensity phase imaging devices for quantitative phase microscopy applications
    Wang, Shouyu
    Huang, Huachuan
    Sun, Aihui
    Zhu, Lin
    Guo, Wei
    Yan, Keding
    Xue, Liang
    [J]. SENSORS & DIAGNOSTICS, 2024, 3 (03): : 381 - 394
  • [5] Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography
    Ricke, J
    Fischbach, F
    Freund, T
    Teichgräber, U
    Hänninen, EL
    Röttgen, R
    Engert, U
    Eichstädt, H
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (12) : 2577 - 2582
  • [6] Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography
    Jens Ricke
    Frank Fischbach
    Torsten Freund
    Ulf Teichgräber
    Enrique Lopez Hänninen
    Rainer Röttgen
    Ulrike Engert
    Hermann Eichstädt
    Roland Felix
    [J]. European Radiology, 2003, 13 : 2577 - 2582
  • [7] Quantitative phase microscopy for cellular dynamics based on transport of intensity equation
    Li, Ying
    Di, Jianglei
    Ma, Chaojie
    Zhang, Jiwei
    Zhong, Jinzhan
    Wang, Kaiqiang
    Xi, Teli
    Zhao, Jianlin
    [J]. OPTICS EXPRESS, 2018, 26 (01): : 586 - 593
  • [8] Adaptive Calibration for Fusion-Based Cyber-Physical Systems
    Tan, Rui
    Xing, Guoliang
    Liu, Xue
    Yao, Jianguo
    Yuan, Zhaohui
    [J]. ACM TRANSACTIONS ON EMBEDDED COMPUTING SYSTEMS, 2012, 11 (04)
  • [9] Real-Time Cellular Phase Imaging Using Dual-View Transport of Intensity Phase Microscopy
    Sun, Shaowei
    Jiang, Zhilong
    Kong, Yan
    He, Xiaoliang
    Liu, Cheng
    Wang, Shouyu
    [J]. ELEVENTH INTERNATIONAL CONFERENCE ON INFORMATION OPTICS AND PHOTONICS (CIOP 2019), 2019, 11209
  • [10] Exposure Fusion-Based Shadow-Insensitive Hyperspectral Target Detection
    Zhang, Shuo
    Mo, Yan
    Kang, Xudong
    Li, Shutao
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2024, 62 : 1 - 11