摘要
The aim of this study was to compare the sensitivity and specificity of digital chest radiography alone with digital chest radiography combined with dual-energy chest radiography in the detection of small non-calcified pulmonary nodules. Standard and dual-energy radiographs were obtained with a flat-panel digital chest system. Four radiologists reviewed digital posteroanterior chest radiographs in random order either alone or in conjunction with dual-energy soft tissue and bone images. Twenty patients with a total of 59 pulmonary nodules (median 0.5 cm, range 0.3 – 2.5 cm) confirmed by computed tomography (HU ≤100) were included. A level of confidence for each diagnosis was documented using a rating scale of 1–5. Brunner and Langer's test was performed for statistical analysis. Subgroup analysis was performed for nodules greater than 1 cm, 1–0.5 cm, and <0.5 cm. For posteroanterior chest radiography, sensitivity was 33%, positive predictive value 83%, specificity 81%, and negative predictive value 30%. Review in conjunction with dual-energy images resulted in a sensitivity of 42%, positive predictive value 88%, specificity 85%, and negative predictive value 34%. The increase of nodule detection overall as well as for different size categories was significant (p<0.05). The increase of the confidence level rating was also significant (p<0.001). Dual energy added to standard posteroanterior chest radiography significantly improves the sensitivity, specificity, and confidence in detection of small non-calcified pulmonary nodules.
引用
收藏
页码:2577 / 2582
页数:5
相关论文
共 50 条
  • [1] Clinical results of CsI-detector-based dual-exposure dual energy in chest radiography
    Ricke, J
    Fischbach, F
    Freund, T
    Teichgräber, U
    Hänninen, EL
    Röttgen, R
    Engert, U
    Eichstädt, H
    Felix, R
    [J]. EUROPEAN RADIOLOGY, 2003, 13 (12) : 2577 - 2582
  • [2] CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial
    Ricarda Rühl
    Magdalena M. Wozniak
    Michael Werk
    François Laurent
    Georg Mager
    Michel Montaudon
    Andreas Pattermann
    Antoine Scherrer
    Jean-Pierre Tasu
    Maciej Pech
    Jens Ricke
    [J]. European Radiology, 2008, 18
  • [3] CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection:: results of an international multicenter trial
    Ruehl, Ricarda
    Wozniak, Magdalena M.
    Werk, Michael
    Laurent, Francois
    Mager, Georg
    Montaudon, Michel
    Pattermann, Andreas
    Scherrer, Antoine
    Tasu, Jean-Pierre
    Pech, Maciej
    Ricke, Jens
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (09) : 1831 - 1839
  • [4] CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection: results of an international multicenter trial
    Ricarda Rühl
    Magdalena M. Wozniak
    Michael Werk
    François Laurent
    Georg Mager
    Michel Montaudon
    Andreas Pattermann
    Antoine Scherrer
    Jean-Pierre Tasu
    Maciej Pech
    Jens Ricke
    [J]. European Radiology, 2008, 18 : 2355 - 2355
  • [5] CsI-detector-based dual-exposure dual energy in chest radiography for lung nodule detection:: results of an international multicenter trial (vol 18, pg 1831, 2008)
    Ruehl, Ricarda
    Wozniak, Magdalena M.
    Werk, Michael
    Laurent, Francois
    Mager, Georg
    Montaudon, Michel
    Pattermann, Andreas
    Scherrer, Antoine
    Tasu, Jean-Pierre
    Pech, Maciej
    Ricke, Jens
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (10) : 2355 - 2355
  • [6] Effect of dose on image quality in a detector-based dual-exposure, dual-energy system for chest radiography
    Freund, T
    Fischbach, F
    Teichgraeber, U
    Haenninen, EL
    Eichstaedt, H
    Felix, R
    Ricke, J
    [J]. ACTA RADIOLOGICA, 2005, 46 (01) : 41 - 47
  • [7] COMPARISON OF DUAL AND SINGLE EXPOSURE TECHNIQUES IN DUAL-ENERGY CHEST RADIOGRAPHY
    HO, JT
    KRUGER, RA
    SORENSON, JA
    [J]. MEDICAL PHYSICS, 1989, 16 (02) : 202 - 208
  • [8] Vertical magnification correction in vertical dual-exposure panoramic radiography
    Kimoto, Hideaki
    Asakura, Shoichi
    Sasaki, Tatsuhiko
    Dezawa, Ko
    Amemiya, Toshihiko
    Matsumoto, Kunihito
    Arai, Yoshinori
    [J]. JOURNAL OF ORAL SCIENCE, 2024, 66 (01) : 70 - 74
  • [9] Dual-Energy, Dual-Exposure PA and Lateral Chest Radiograph: Not Your Father's Chest X-Ray
    Boswell, Gilbert E.
    Wolfgramm, Sione T.
    Fong, Raynard K.
    Hawley, Daniel B.
    [J]. MILITARY MEDICINE, 2023, 188 (1-2) : 12 - 15
  • [10] Feasibility of using a kinestatic charge detector for dual-energy chest radiography
    Schmithorst, Vincent J.
    Endorf, Robert J.
    Kulatunga, Sunil
    Spelic, David C.
    DiBianca, Frank A.
    Rodriguez, Carlos
    Zeman, Herbert D.
    Zhu, Zeping
    Giakos, George C.
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2004, 12 (01) : 1 - 11