Reproducibility of Doppler echocardiographic assessment of left ventricular diastolic function in multicenter setting

被引:25
|
作者
Palmieri, V
Innocenti, F
Pini, R
Celentano, A
机构
[1] Univ Naples Federico 2, Fac Med & Chirurg, Sch Med, Dept Clin & Expt Med, I-80131 Naples, Italy
[2] Osped ASL NAI, Ctr Traumatol, Naples, Italy
[3] Careggi Univ Hosp, Dept Crit Care Med & Surg, Unit Gerontol & Geriatr, Florence, Italy
关键词
D O I
10.1016/j.echo.2004.08.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Whether Doppler echocardiography allows reliable assessment of left ventricular (LV) diastolic parameters in multicenter studies is disputed. Methods. To assess interstudy reproducibility of Doppler echocardiographic parameters of LV filling and relaxation in multicenter setting, two laboratories assessed Doppler parameters of LV filling and relaxation twice within 24 hours in 56 participants. The study sample included hospitalized patients, clinically healthy outpatients, and healthy volunteers. All studies were performed according to a standardized protocol, and read by a single reader. Results: in the whole study sample die reproducibility of the assessment of the ratio between die peak velocities of the early (E) and late (A) LV filling waves (E/A), of the E wave deceleration time and atrial filling fraction, measured at the mitral valve leaflet tips, was good (intraclass correlation coefficients, p: 0.89-0.76); the reproducibility performance of the same parameters measured at the mitral anulus was less good. The reproducibility of the assessment of the isovolumic relaxation time was good (P: 0.81), and that of the E-wave propagation rate (E-Vp), by color M-mode, was excellent (P: 0.96). The reproducibility of the ratio E wave peak velocity/E-Vp was also fairly good (P: 0.87). The classification of E-Vp < 45 cm/s and E-Vp greater than or equal to 55 cm/s showed the highest between-study reliability performance (agreement index kappa = 0.92 and 0.83, respectively, both P < .001), followed by E/A at mitral leaflet tips > 1.5 or < 0.8 (kappa = 0.78 and 0.74, respectively, both P < .01), whereas the worst reliability performance was shown by isovolumic relaxation time < 60 milliseconds (kappa = 0.05, P = not significant). Conclusions. Standardized procedures for imaging and readings allowed good reliability of serial Doppler echocardiographic evaluations of LV filling and relaxation parameters in multicenter setting.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 50 条
  • [31] DOPPLER-ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH PROGRESSIVE SYSTEMIC-SCLEROSIS
    FUJIMOTO, S
    KAGOSHIMA, T
    NAKAJIMA, T
    DOHI, K
    CARDIOLOGY, 1993, 83 (04) : 217 - 227
  • [32] Which echocardiographic doppler left ventricular diastolic function measurements are most feasible in the clinical echocardiographic laboratory?
    Khan, S
    Bess, RL
    Rosman, HS
    Nordstrom, CK
    Cohen, GI
    Gardin, JM
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (08): : 1099 - 1101
  • [33] ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION - A COMPARATIVE-ANALYSIS OF DOPPLER ECHOCARDIOGRAPHIC AND RADIONUCLIDE ANGIOGRAPHIC TECHNIQUES
    SPIRITO, P
    MARON, BJ
    CRAWFORDGREEN, C
    BONOW, RO
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 5 (02) : 427 - 427
  • [34] DOPPLER-ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH SYSTEMIC LUPUS-ERYTHEMATOSUS
    FUJIMOTO, S
    KAGOSHIMA, T
    NAKAJIMA, T
    DOHI, K
    CARDIOLOGY, 1994, 85 (3-4) : 267 - 272
  • [35] FACTORS INFLUENCING DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN AORTIC-VALVE STENOSIS
    DANIELSEN, R
    AMERICAN JOURNAL OF NONINVASIVE CARDIOLOGY, 1991, 5 (01): : 20 - 25
  • [36] DOPPLER ECHOCARDIOGRAPHIC EVALUATION OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS WITH SYSTEMIC SARCOIDOSIS
    ANGOMACHALELIS, N
    HOURZAMANIS, A
    VAMVALIS, C
    GAVRIELIDES, A
    POSTGRADUATE MEDICAL JOURNAL, 1992, 68 : S52 - S56
  • [37] PULSED DOPPLER ECHOCARDIOGRAPHIC INDEXES OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN NORMAL SUBJECTS
    BAHL, VK
    DAVE, TH
    SUNDARAM, KR
    SHRIVASTAVA, S
    CLINICAL CARDIOLOGY, 1992, 15 (07) : 504 - 512
  • [38] LEFT-VENTRICULAR DIASTOLIC FUNCTION IN PATIENTS ON MAINTENANCE HEMODIALYSIS - A DOPPLER ECHOCARDIOGRAPHIC STUDY
    JOSEPHS, W
    LENGA, P
    ODENTHAL, HJ
    WIECHMANN, HW
    KIDNEY INTERNATIONAL, 1990, 37 (04) : 1176 - 1176
  • [39] LEFT-VENTRICULAR DIASTOLIC FUNCTION IN HEART-FAILURE - A DOPPLER ECHOCARDIOGRAPHIC STUDY
    HORSTMANN, E
    BENN, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1989, 78 (11): : 738 - 744
  • [40] A DOPPLER ECHOCARDIOGRAPHIC STUDY OF LEFT-VENTRICULAR DIASTOLIC FUNCTION IN AORTIC-STENOSIS
    HABIB, G
    VITTOT, P
    CORNEN, A
    BOULAIN, L
    BONNET, JL
    DJIANE, P
    LUCCIONI, R