A comparison between track-structure, condensed-history Monte Carlo simulations and MIRD cellular S-values

被引:12
|
作者
Tajik-Mansoury, M. A. [1 ]
Rajabi, H. [2 ]
Mozdarani, H. [3 ]
机构
[1] Semnan Univ Med Sci, Fac Med Sci, Dept Med Phys, Semnan, Iran
[2] Tarbiat Modares Univ, Fac Med Sci, Dept Med Phys, Tehran, Iran
[3] Tarbiat Modares Univ, Fac Med Sci, Dept Med Genet, Tehran, Iran
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2017年 / 62卷 / 05期
关键词
cellular S-values; track-structure; condensed-history; MIRD; Geant4; BETA-EMITTING RADIONUCLIDES; LOW-ENERGY ELECTRONS; ELECTROMAGNETIC PHYSICS; RADIATION BIOLOGY; STRUCTURE CODES; IN-VITRO; THERAPY; GEANT4-DNA; DOSIMETRY; RADIOIMMUNOTHERAPY;
D O I
10.1088/1361-6560/62/5/N90
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these methods have been employed for estimation of cellular S-values, but there is no consistency between the published results. In the present paper, we used the Geant4-DNA track-structure physics model as the reference to estimate the cellular S-values. We compared the results with the corresponding values obtained from the following three condensed-history physics models of Geant4: Penelope, Livermore and standard. The geometry and source were exactly the same in all the simulations. We utilized mono-energetic electrons with an initial kinetic energy in the range 1-700 keV as the source of radiation. We also compared our results with the MIRD S-values. We first drew an overall comparison between different data series and then compared the dependence of results on the energy of particles and the size of scoring compartments. The overall comparison indicated a very good linear correlation (R-2 > 91%) and small bias (3%) between the results of the track-structure model and the condensed-history physics model. The bias between MIRD and the results of Monte Carlo track-structure simulation was considerable (-8%). However, the point-by-point comparison revealed differences of up to 28% between the condensed-history and the track-structure MC codes for self-absorption S-values in the 10-50 keV energy range. For the cross-absorption S-values, the difference was up to 34%. In this energy range, the difference between the MIRD S-values and the Geant4-DNA results was up to 68%. Our findings suggest that the consistency/inconsistency of the results obtained with different MC simulations depends on the size of the scoring volumes, the energy of the particles, the step-size in electron tracking and the energy cutoff used in the MC codes.
引用
收藏
页码:N90 / N106
页数:17
相关论文
共 24 条
  • [21] Monte Carlo calculations of the cellular S-values for α-particle-emitting radionuclides incorporated into the nuclei of cancer cells of the MDA-MB231, MCF7 and PC3 lines
    Rojas-Calderon, E. L.
    Avila, O.
    Ferro-Flores, G.
    APPLIED RADIATION AND ISOTOPES, 2018, 135 : 1 - 6
  • [22] Layered structure of friction films revealed by the comparison between multi-energy X-ray microanalysis and Monte Carlo simulations
    Vasconcellos, M. A. Z.
    Soares, Marcio R. F.
    Hinrichs, Ruth
    WEAR, 2012, 294 : 347 - 355
  • [23] Monte Carlo N-Particle (MCNP) Modeling of the Cellular Dosimetry of 64Cu: Comparison with MIRDcell S Values and Implications for Studies of Its Cytotoxic Effects
    Cai, Zhongli
    Kwon, Yongkyu Luke
    Reilly, Raymond M.
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (02) : 339 - 345
  • [24] Comparison between MCNP4-C and MCNPX (2.6F) Monte-Carlo simulations codes, in the calculation of mouse S-factors
    Boutaleb, Samir
    Pouget, Jean-Pierre
    Pelegrin, Andre
    Kotzki, Pierre-Olivier
    Bardies, Manuel
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50