摘要
The S-value is a standard measure in cellular dosimetry. S-values are calculated by applying analytical methods or by Monte Carlo simulation. In Monte Carlo simulation, particles are either tracked individually event-by-event or close events are condensed and processed collectively in different steps. Both of these methods have been employed for estimation of cellular S-values, but there is no consistency between the published results. In the present paper, we used the Geant4-DNA track-structure physics model as the reference to estimate the cellular S-values. We compared the results with the corresponding values obtained from the following three condensed-history physics models of Geant4: Penelope, Livermore and standard. The geometry and source were exactly the same in all the simulations. We utilized mono-energetic electrons with an initial kinetic energy in the range 1-700 keV as the source of radiation. We also compared our results with the MIRD S-values. We first drew an overall comparison between different data series and then compared the dependence of results on the energy of particles and the size of scoring compartments. The overall comparison indicated a very good linear correlation (R-2 > 91%) and small bias (3%) between the results of the track-structure model and the condensed-history physics model. The bias between MIRD and the results of Monte Carlo track-structure simulation was considerable (-8%). However, the point-by-point comparison revealed differences of up to 28% between the condensed-history and the track-structure MC codes for self-absorption S-values in the 10-50 keV energy range. For the cross-absorption S-values, the difference was up to 34%. In this energy range, the difference between the MIRD S-values and the Geant4-DNA results was up to 68%. Our findings suggest that the consistency/inconsistency of the results obtained with different MC simulations depends on the size of the scoring volumes, the energy of the particles, the step-size in electron tracking and the energy cutoff used in the MC codes.
引用
收藏
页码:N90 / N106
页数:17
相关论文
共 24 条
  • [1] Monte Carlo track-structure for the radionuclide Copper-64: characterization of S-values, nanodosimetry and quantification of direct damage to DNA
    Carrasco-Hernandez, J.
    Ramos-Mendez, J.
    Faddegon, B.
    Jalilian, A. R.
    Moranchel, M.
    Avila-Rodriguez, M. A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (15):
  • [2] Cellular S-value of beta emitter radionuclide's determined using Geant4 Monte Carlo toolbox, comparison to MIRD S-values
    Tajik-Mansoury, Mohammad Ali
    Rajabi, Hossein
    Mozdarani, Hossein
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2016, 24 (01): : 37 - 45
  • [3] High-speed evaluation of track-structure Monte Carlo electron transport simulations
    Pasciak, A. S.
    Ford, J. R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19): : 5539 - 5553
  • [4] CELLULAR S-VALUES GENERATED WITH THE MONTE CARLO CODES PENELOPE, MCNPX AND GEANT4
    Uusijarvi, H.
    Chouin, N.
    Bardies, M.
    Fernandez-Varea, J. M.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S404 - S404
  • [5] Impact of DNA Geometry and Scoring on Monte Carlo Track-Structure Simulations of Initial Radiation-Induced Damage
    Bertolet, Alejandro
    Ramos-Mendez, Jose
    McNamara, Aimee
    Yoo, Dohyeon
    Ingram, Samuel
    Henthorn, Nicholas
    Warmenhoven, John-William
    Faddegon, Bruce
    Merchant, Michael
    McMahon, Stephen J.
    Paganetti, Harald
    Schuemann, Jan
    RADIATION RESEARCH, 2022, 198 (03) : 207 - 220
  • [6] Comparison of Geant4-DNA simulation of S-values with other Monte Carlo codes
    Andre, T.
    Morini, F.
    Karamitros, M.
    Delorme, R.
    Le Loirec, C.
    Campos, L.
    Champion, C.
    Groetz, J. -E.
    Fromm, M.
    Bordage, M. -C.
    Perrot, Y.
    Barberet, Ph
    Bernal, M. A.
    Brown, J. M. C.
    Deleuze, M. S.
    Francis, Z.
    Ivanchenko, V.
    Mascialino, B.
    Zacharatou, C.
    Bardies, M.
    Incerti, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2014, 319 : 87 - 94
  • [7] Calculation of S-values for Technetium-99m in the DIGIMOUSE voxel phantom using Monte Carlo simulations
    Teles, P.
    Antunes, J.
    Gomez-Ros, J. M.
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196
  • [8] Estimation of absorbed radiation doses to skin and S-values for organs at risk due to nasal administration of PET agents using Monte Carlo simulations
    O'Doherty, Jim
    Mangini, Colby D.
    Hamby, David M.
    Boozer, David
    Singh, Nisha
    Hippelainen, Eero
    MEDICAL PHYSICS, 2021, 48 (02) : 871 - 880
  • [9] A Comparison of External Beam Radiotherapy and Radiopharmaceutical Lineal Energy Distributions Using Monte Carlo Track Structure Simulations
    Adam, D.
    Grudzinski, J.
    Bednarz, B.
    MEDICAL PHYSICS, 2020, 47 (06) : E676 - E676
  • [10] Inelastic scattering of electrons in water from first principles: cross sections and inelastic mean free path for use in Monte Carlo track-structure simulations of biological damage
    Koval, Natalia E. E.
    Koval, Peter
    Da Pieve, Fabiana
    Kohanoff, Jorge
    Artacho, Emilio
    Emfietzoglou, Dimitris
    ROYAL SOCIETY OPEN SCIENCE, 2022, 9 (05):