Patient-specific instrumentation for total knee arthroplasty improves reproducibility in the planned rotational positioning of the tibial component

被引:2
|
作者
Sotozawa, Masaichi [1 ]
Kumagai, Ken [1 ]
Yamada, Shunsuke [1 ]
Nejima, Shuntaro [1 ]
Inaba, Yutaka [1 ]
机构
[1] Yokohama City Univ, Yokohama City Univ Hosp, Grad Sch Med, Dept Orthopaed Surg,Kanazawa Ku, 3-9 Fukuura, Yokohama, Kanagawa 2360004, Japan
关键词
Total knee arthroplasty; Patient-specific instrumentation; Conventional method; Tibial rotational alignment; POSTOPERATIVE ALIGNMENT; FEMORAL COMPONENT; TKA; REPLACEMENT; OUTCOMES; LEVEL;
D O I
10.1186/s13018-022-03298-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background The purpose of this study was to evaluate the reproducibility of planned component positioning including tibial rotational alignment in patient-specific instrumentation (PSI) for total knee arthroplasty (TKA). Methods A total of 100 knees of 100 patients underwent TKA using PSI (n = 50) or the conventional method (n = 50). Full-length anteroposterior radiographs of the lower limb were taken in the standing position, and the coronal alignments of the femoral and tibial components were measured. Computed tomography (CT) images of the lower limb were obtained preoperatively and postoperatively, and the rotational alignments of the femoral and tibial components were measured. The difference from the preoperative planning in tibial rotational alignment was measured using three-dimensionally merged pre- and postoperative images. The mean values and rates of outliers in each measurement were compared between the PSI group and the conventional group. Results There were no significant differences in coronal alignment of the femoral and tibial components and rotational alignment of the femoral component between the two groups. With respect to rotational alignment of the tibial component from the preoperatively planned reference axis, the PSI group showed a lower rate of outliers (internal rotation > 10 degrees) than the conventional group (p < 0.05). Conclusions This study demonstrated that the difference from the preoperative planning in tibial rotational positioning was accurately evaluated using novel three-dimensional measurement method, and PSI could reduce outliers in rotational alignment of the tibial component (internal rotation > 10 degrees). PSI is a useful technique for improving the reproducibility of the planned tibial rotational positioning in TKA.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of planned and achieved implant position in total knee arthroplasty with patient-specific positioning guides
    van Leeuwen, Justin A. M. J.
    Grogard, Bjarne
    Nordsletten, Lars
    Rohrl, Stephan M.
    ACTA ORTHOPAEDICA, 2015, 86 (02) : 202 - 207
  • [22] Patient-Specific Instrumentation in Total Knee Arthroplasty: What Is the Evidence?
    Szczech, Bartlomiej
    McDermott, James D.
    Issa, Kimona
    Rifai, Aiman
    Festa, Anthony
    Matarese, William A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2016, 29 (04) : 341 - 345
  • [23] Reliability of Templating with Patient-Specific Instrumentation in Total Knee Arthroplasty
    Issa, Kimona
    Rifai, Aiman
    McGrath, Mike S.
    Callaghan, John J.
    Wright, Craig
    Malkani, Arthur L.
    Mont, Michael A.
    McInerney, Vincent K.
    JOURNAL OF KNEE SURGERY, 2013, 26 (06) : 429 - 433
  • [24] Patient-specific instrumentation makes sense in total knee arthroplasty
    Leon-Munoz, Vicente J.
    Lopez-Lopez, Mirian
    Santonja-Medina, Fernando
    EXPERT REVIEW OF MEDICAL DEVICES, 2022, 19 (06) : 489 - 497
  • [25] Total Knee Arthroplasty: Validating The Benefits Of Patient-Specific Instrumentation
    Moore, S.
    Linton, K. N.
    Martin, P.
    Headon, R. J.
    Bennett, D.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S74 - S75
  • [26] Accuracy and Reproducibility Using Patient-Specific Instrumentation in Total Ankle Arthroplasty
    Daigre, Justin
    Berlet, Gregory
    Van Dyke, Bryan
    Peterson, Kyle S.
    Santrock, Robert
    FOOT & ANKLE INTERNATIONAL, 2017, 38 (04) : 412 - 418
  • [27] Accuracy of Patient-Specific Instrumentation Compared With Conventional Instrumentation in Total Knee Arthroplasty
    Jiang, Jin
    Kang, Xin
    Lin, Qiao
    Teng, Yuanjun
    An, Liping
    Ma, Jingling
    Wang, Jing
    Xia, Yayi
    ORTHOPEDICS, 2015, 38 (04) : E305 - E313
  • [28] Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation
    Smolle, Maria Anna
    Koutp, Amir
    Clar, Clemens
    Leitner, Lukas
    Leithner, Andreas
    Sadoghi, Patrick
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5867 - 5872
  • [29] Restoring tibial obliquity for kinematic alignment in total knee arthroplasty: conventional versus patient-specific instrumentation
    Maria Anna Smolle
    Amir Koutp
    Clemens Clar
    Lukas Leitner
    Andreas Leithner
    Patrick Sadoghi
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5867 - 5872
  • [30] The Effect of Patient-Specific Instrumentation Incorporating an Extramedullary Tibial Guide on Operative Efficiency for Total Knee Arthroplasty
    Kwon, Oh-Ryong
    Kang, Kyoung-Tak
    Son, Juhyun
    Suh, Dong-Suk
    Heo, Dong Beom
    Koh, Yong-Gon
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017