Measurement error analysis of binocular stereo vision: effective guidelines for bionic eyes

被引:18
|
作者
Wang, Qingbin [1 ,2 ]
Yin, Yingjie [1 ]
Zou, Wei [1 ]
Xu, De [1 ,2 ]
机构
[1] Chinese Acad Sci, Res Ctr Precis Sensing & Control, Inst Automat, 95 Zhongguancun East Rd, Beijing 100190, Peoples R China
[2] Univ Chinese Acad Sci, 19 Yuquan Rd, Beijing 100049, Peoples R China
基金
国家高技术研究发展计划(863计划); 中国国家自然科学基金;
关键词
measurement errors; stereo image processing; biocybernetics; spatial variables measurement; feature extraction; measurement error analysis; binocular stereo vision; bionic eyes; active cameras; rotation angle errors; image feature extraction errors; depth measurement; calculation formula; angular velocity; DESIGN;
D O I
10.1049/iet-smt.2016.0359
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The depth measurement error of bionic eyes consisting of two active cameras is derived by considering the eyes' rotation angle errors and image feature extraction errors. The effect factors of the depth measurement are obtained from the calculation formula of depth error. Based on the analysis of these effect factors, some effective guidelines for bionic eyes are proposed to reduce the measurement errors. The guidelines suggest keeping long baseline, observing the target as nearly as possible, controlling two active cameras with the same angular velocity and keeping the target on Z(w) axis if possible. The simulation experiments and practical experiments in bionic eyes platform validate the effectiveness of the proposed guidelines.
引用
收藏
页码:829 / 838
页数:10
相关论文
共 50 条
  • [1] Error analysis and compensation of binocular-stereo-vision measurement system
    Zhang Tao
    Guo Junjie
    [J]. NINTH INTERNATIONAL SYMPOSIUM ON LASER METROLOGY, PTS 1 AND 2, 2008, 7155
  • [2] Error analysis of binocular stereo vision system applied in small scale measurement
    Lu, Bao-Li
    Liu, Yu-Liang
    Sun, Liang
    [J]. Guangzi Xuebao/Acta Photonica Sinica, 2015, 44 (10):
  • [3] A New Method for Error Analysis of Binocular Stereo Vision System
    Chen, Wenwen
    Zhang, Zhibin
    Li, Hui
    Hou, Shuaimin
    [J]. 2019 INTERNATIONAL CONFERENCE ON CYBER-ENABLED DISTRIBUTED COMPUTING AND KNOWLEDGE DISCOVERY (CYBERC), 2019, : 125 - 130
  • [4] Measurement error analysis of three dimensional coordinates of tomatoes acquired using the binocular stereo vision
    Xiang, Rong
    [J]. 7TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTOELECTRONICS MATERIALS AND DEVICES FOR SENSING AND IMAGING, 2014, 9284
  • [5] The analysis of measurement accuracy of the parallel binocular stereo vision system
    Yu Huan
    Xing Tingwen
    Jia Xin
    [J]. 8TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGY: OPTICAL TEST, MEASUREMENT TECHNOLOGY, AND EQUIPMENT, 2016, 9684
  • [6] The AUV location and location error analysis based on binocular stereo vision
    Gao, Jun-Chai
    Liu, Ming-Yong
    Xu, Fei
    [J]. Sensors and Transducers, 2013, 156 (09): : 291 - 297
  • [7] Error Analysis of Calibration Parameters Estimation for Binocular Stereo Vision System
    Xu, Yafan
    Zhao, Yan
    Wu, Falin
    Yang, Kui
    [J]. 2013 IEEE INTERNATIONAL CONFERENCE ON IMAGING SYSTEMS AND TECHNIQUES (IST 2013), 2013, : 317 - 320
  • [8] A Measurement Method Based on Binocular Stereo Vision
    Wang, Han
    Gao, Jingbo
    Huang, Lu
    [J]. 2016 INTERNATIONAL CONFERENCE ON MATERIAL, ENERGY AND ENVIRONMENT ENGINEERING (ICM3E 2016), 2016, : 339 - 342
  • [9] Measurement of curved surface by stereo vision and error analysis
    Luo, PF
    Liou, SS
    [J]. OPTICS AND LASERS IN ENGINEERING, 1998, 30 (06) : 471 - 486
  • [10] An error analysis and optimization method for combined measurement with binocular vision
    Yongkang LU
    Wei LIU
    Yang ZHANG
    Junqing LI
    Weiqi LUO
    Yanze ZHANG
    Hongwen XING
    Lei ZHANG
    [J]. Chinese Journal of Aeronautics, 2021, 34 (10) : 282 - 292