Effectiveness and Safety of Insulin Glargine 300 U/ml in Comparison with Insulin Degludec 100 U/ml Evaluated with Continuous Glucose Monitoring in Adults with Type 1 Diabetes and Suboptimal Glycemic Control in Routine Clinical Practice: The OneCARE Study

被引:13
|
作者
Conget, Ignacio [1 ]
Angel Mangas, Miguel [2 ]
Morales, Cristobal [3 ,4 ]
Caro, Juan [5 ]
Gimenez, Margarita [1 ]
Borrell, Mireia [6 ]
Delgado, Elias [7 ,8 ,9 ,10 ]
机构
[1] Hosp Clin Barcelona, C Villarroel 170, Barcelona 08036, Spain
[2] Hosp Univ Virgen Rocio, Ave Manuel Siurot S-N, Seville 41013, Spain
[3] Hosp Univ Virgen Macarena, Calle Dr Fedriani 3, Seville 41009, Spain
[4] Hosp Vithas Sevilla, Avda Placido Fernandez Viagas S-N, Seville 41950, Spain
[5] Clin MediNorte, Av Marques Sotelo 13,1 2, Valencia 46002, Spain
[6] C Josep Pla 2, Barcelona 08019, Spain
[7] Univ Oviedo, Oviedo, Spain
[8] Hosp Univ Cent Asturias, Ave Roma S-N, Oviedo 33011, Spain
[9] Inst Invest Biomed Principado Asturias, Oviedo, Spain
[10] CIBERER, Oviedo, Spain
关键词
CGM; Gla-300; Glycemic control; T1D; LESS HYPOGLYCEMIA; PEOPLE; VARIABILITY; UNITS/ML; TRIAL; MULTICENTER; PROTRACTION; INJECTIONS; AWARENESS; PROFILES;
D O I
10.1007/s13300-021-01153-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Data regarding efficacy of second-generation basal insulins (BI) using continuous glucose monitoring (CGM) come from clinical trials. We evaluated the effectiveness of insulin glargine 300 U/ml (Gla-300) compared to insulin degludec 100 U/ml (IDeg-100) in terms of percentage of time in range (TIR); 70-180 mg/dl was obtained from CGM in sub-optimally controlled patients with type 1 diabetes (T1D) in routine clinical practice. Methods This observational, multicenter, cross-sectional study included patients with T1D (> 3 years diabetes duration, HbA(1c) >= 7.5%) who had switched from first-generation BI to Gla-300/IDeg-100 within the past 24 months according to physician discretion. Clinical and laboratory data were obtained from clinical records and during study visit, and CGM data were collected prior to the visit. Results One hundred ninety-nine people with T1D were included [42.6 +/- 13.4 (mean +/- SD) years, 18.4 +/- 10.4 years diabetes duration]; 104 received Gla-300, 95 IDeg-100. TIR 70-180 throughout whole day was similar in both groups, 52.4 +/- 14.0 vs. 49.3 +/- 13.9% Gla-300/IDeg-100, respectively. At night, TIR 70-180 and TIR 70-140 were significantly higher in the Gla-300 group compared to the IDeg-100 (52.4 vs. 46.2 and 31.8 vs. 26.9%, respectively, p = 0.0209 and p = 0.0182), and time above range (180) was significantly lower in the Gla-300 group (40.1% vs. 47.2%, p = 0.0199). Additional CGM glucometric data were comparable in both groups. Patient treatment satisfaction score assessed through the Diabetes Treatment Satisfaction Questionnaire (DTSQ) was high and similar for both insulins. Conclusion This real-world study shows the effectiveness and safety of Gla-300 are more similar to than different from IDeg-100, with a slightly better nocturnal glucose profile, in sub-optimally controlled T1D patients switching from a first-generation BI.
引用
收藏
页码:2993 / 3009
页数:17
相关论文
共 50 条
  • [1] Effectiveness and Safety of Insulin Glargine 300 U/ml in Comparison with Insulin Degludec 100 U/ml Evaluated with Continuous Glucose Monitoring in Adults with Type 1 Diabetes and Suboptimal Glycemic Control in Routine Clinical Practice: The OneCARE Study
    Ignacio Conget
    Miguel Ángel Mangas
    Cristóbal Morales
    Juan Caro
    Margarita Giménez
    Mireia Borrell
    Elías Delgado
    Diabetes Therapy, 2021, 12 : 2993 - 3009
  • [2] In Silico Head-to-Head Comparison of Insulin Glargine 300 U/mL and Insulin Degludec 100 U/mL in Type 1 Diabetes
    Schiavon, Michele
    Visentin, Roberto
    Giegerich, Clemens
    Sieber, Jochen
    Dalla Man, Chiara
    Cobelli, Claudio
    Klabunde, Thomas
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 (08) : 553 - 561
  • [3] Improved Glycemic Control with Insulin Glargine 300 U/mL vs. Glargine 100 U/mL in Type 1 Diabetes
    Paola, Lucidi
    Cioli, Patrizia
    Candeloro, Paola
    Andreoli, Anna Marinelli
    Bolli, Geremia B.
    Fanelli, Carmine G.
    Porcellati, Francesca
    DIABETES, 2020, 69
  • [4] Insulin glargine 300 U/ml versus insulin degludec 100 U/ml improves nocturnal glycaemic control and variability in type 1 diabetes under routine clinical practice: A glucodensities-based post hoc analysis of the OneCare study
    Gomez-Peralta, Fernando
    Ballesteros, Ana Chico
    Martinez, Amparo Marco
    Corral, Begona Perez
    Donlo, Ignacio Conget
    Melo, Paulina Fuentealba
    Arnaez, Fernando Zaragoza
    Rodriguez, Marcos Matabuena
    DIABETES OBESITY & METABOLISM, 2024, 26 (05): : 1993 - 1997
  • [5] Comparative effectiveness of insulin glargine 300 U/mL and insulin degludec 100 U/mL in insulin naive type 2 diabetes adults: the Restore-2 naive cohort
    Fadini, G. P.
    Buzzetti, R.
    Larosa, M.
    Rossi, M. C.
    Nicolucci, A.
    Cucinotta, D.
    DIABETOLOGIA, 2021, 64 (SUPPL 1) : 74 - 74
  • [6] COST-UTILITY ANALYSIS OF INSULIN GLARGINE 300 U/ML VERSUS INSULIN GLARGINE 100 U/ML AND INSULIN DEGLUDEC 100 U/ML IN PATIENTS WITH TYPE 2 DIABETES MELLITUS IN CROATIA
    Bogdanovic, M.
    Fournier, M.
    Vitezic, D.
    VALUE IN HEALTH, 2018, 21 : S131 - S132
  • [7] COST-UTILITY EVALUATION OF INSULIN GLARGINE (300 U/ML) VERSUS INSULIN GLARGINE (100 U/ML) AND INSULIN DEGLUDEC (100 U/ML) IN PATIENTS WITH TYPE 2 DIABETES MELLITUS IN SLOVENIA
    Bogdanovic, M.
    Krnel, Rados S.
    Foumier, M.
    VALUE IN HEALTH, 2017, 20 (09) : A481 - A481
  • [8] COST-UTILITY ANALYSIS OF INSULIN GLARGINE 300 U/ML VERSUS INSULIN GLARGINE 100 U/ML AND INSULIN DEGLUDEC 100 U/ML IN PATIENTS WITH TYPE 2 DIABETES MELLITUS IN BULGARIA
    Bogdanovic, M.
    Mihajlovic, J.
    Fournier, M.
    VALUE IN HEALTH, 2018, 21 : S133 - S133
  • [9] An Exploratory Study to Evaluate the Glycemic Variability by Continuous Glucose Monitoring (CGM) with Insulin Glargine 300 U/mL vs. Glargine 100 U/mL in Patients with Type 2 Diabetes
    Franco, Denise R.
    Visconti, Guilherme D.
    Feder, Cecilia
    Baptista, Juliana
    Vianna, Andre G.
    Guimaraes, Mariana T.
    Souza, Flavia V.
    Tagata, Luciana A.
    Eliaschewitz, Freddy
    DIABETES, 2020, 69
  • [10] InRange: Comparison of the Second-Generation Basal Insulin Analogues Glargine 300 U/mL and Degludec 100 U/mL in Persons with Type 1 Diabetes Using Continuous Glucose Monitoring—Study Design
    Tadej Battelino
    Zsolt Bosnyak
    Thomas Danne
    Bhaswati Mukherjee
    Steve Edelman
    Valerie Pilorget
    Pratik Choudhary
    Eric Renard
    Richard Bergenstal
    Diabetes Therapy, 2020, 11 : 1017 - 1027