Residual Deformity After Treatment of Pediatric Femur Fractures With Flexible Titanium Nails

被引:35
|
作者
Sagan, Michelle L. [1 ]
Datta, Jason C. [2 ]
Olney, Brad W. [3 ]
Lansford, Todd J. [1 ]
McIff, Terence E. [1 ]
机构
[1] Univ Kansas, Med Ctr, Dept Orthoped Surg, Kansas City, KS 66160 USA
[2] UMKC Sch Med, Kansas City, MO USA
[3] Childrens Mercy Hosp, Kansas City, MO 64108 USA
关键词
pediatric femur fracture; flexible titanium nail; titanium elastic nail; deformity; ELASTIC NAILS; INTRAMEDULLARY NAILS; FEMORAL FRACTURES; FIXATION; COMPLICATIONS;
D O I
10.1097/BPO.0b013e3181efb8e2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Procurvatum or anterior bow deformity is a potential complication after treatment of femur fractures with flexible titanium nails (FTNs). This article reports on a clinical evaluation of angulation after treating pediatric femur fractures with FTNs. The article also reports on a complementary investigation of potential causes of these deformities using a biomechanical model. Methods: All pediatric femoral shaft fractures treated with FTNs over a 4-year period were reviewed. Fracture location, pattern, angulation, and nail shoe tip orientation were recorded from postoperative radiographs. Malunion was defined as greater than 10 degrees of angulation on the AP radiograph or greater than 15 degrees on the lateral view. As an adjunct to the clinical study, a synthetic femur model was created using midtransverse fractures. These femurs were nailed using 2 FTNs inserted so as to create constructs having the following combinations of nail shoe tip orientation: both anterior (AA), both posterior (PP), both neutral (NN), or 1 anterior and 1 posterior(AP). The resulting angular deformities noticeable upon gross inspection were then measured. Results: Of the 70 fractures reviewed, malunion occurred in 16 fractures, of which 11 had increased anterior bow. A majority of malunions was observed in older children with middle third of the femur fractures. They were significantly more prevalent in transverse fractures compared with all other fracture patterns. Clinically, increased anterior bowing did not occur if 1 of the nails was positioned to resist procurvatum, as seen in the lateral radiograph. Depending on nail tip orientation, the biomechanical femur fracture model showed significant differences in mean deformations after nail placement: AA had 12.6 degrees of posterior bow compared with 14.8, 3.7, and 0.3 degrees of anterior bow for PP, NN, and AP, respectively. Conclusion: Anterior bowing greater than 15 degrees is the most common malunion noted in this series of femur fractures that were nailed using FTN's. We conclude that final nail shoe tip orientation influences the likelihood of anterior bow deformity. The likelihood of large anterior bowing may be reduced if at least 1 of the nails is inserted with the tip pointing in an anterior direction. Level of Evidence/Clinical Relevance: Level III.
引用
收藏
页码:638 / 643
页数:6
相关论文
共 50 条
  • [41] A Quartet of Elastic Stable Intramedullary Nails for More Challenging Pediatric Femur Fractures
    Busch, Michael T.
    Perkins, Crystal A.
    Nickel, Brian T.
    Blizzard, Daniel J.
    Willimon, Samuel Clifton
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2019, 39 (01) : E12 - E17
  • [42] Treatment of Midshaft Clavicular Fractures With Elastic Titanium Nails
    Shokouh, Hassan Keihan
    Naderi, Mohammad Nasir
    Shokouh, Mahsa Keihan
    TRAUMA MONTHLY, 2014, 19 (03) : 8 - 11
  • [43] Elastic Stable Titanium Flexible Intramedullary Nails Versus Plates in Treating Low Grade Comminuted Femur Shaft Fractures in Children
    Luo, Yi
    Wang, Lin
    Zhao, Li-hua
    Wang, Yi-cheng
    Chen, Meng-jie
    Wang, Sun
    Ma, Qi-chao
    ORTHOPAEDIC SURGERY, 2019, 11 (04) : 664 - 670
  • [44] Functional Outcome of Intramedullary Fixation with Titanium Elastic Nails in Diaphyseal Fractures of Femur in Children
    Mahar, Sijad Ahmed
    Abbasi, Mohammad Kashif
    Bhayo, Azizullah
    Chandio, Mohammad Shoaib
    Palh, Hussain Bux
    Bhatti, Sajjad Hussain
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (02): : 610 - 612
  • [45] Diaphyseal Fractures of Femur in Children: Functional Outcome of Intramedullary Fixation with Titanium Elastic Nails
    Ahmed, Zulfiqar
    Buzdar, Muhammad Iqbal
    Alamzeb, Syed
    Rajput, Irfan Muhammad
    Jalal, Sayed Farooq
    Tippu, Abdul Rauf
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2020, 14 (04): : 1339 - 1341
  • [46] Research Progress on the Treatment of Geriatric Intertrochanteric Femur Fractures with Proximal Femur Bionic Nails (PFBNs)
    Duan, Wenyu
    Liang, Hao
    Fan, Xiaolong
    Zhou, Dongming
    Wang, Yulu
    Zhang, Haidong
    ORTHOPAEDIC SURGERY, 2024, 16 (10) : 2303 - 2310
  • [47] Complications and failures of titanium elastic nailing in pediatric femur fractures
    S. Saseendar
    J. Menon
    D. K. Patro
    European Journal of Orthopaedic Surgery & Traumatology, 2010, 20 : 635 - 644
  • [48] Management of Length Unstable Femur Fractures in Children by Flexible Intramedullary Nails: A Systematic Review
    Garg, V.
    Gowda, A. K. S.
    Regmi, A.
    Barik, S.
    Maheshwari, V. K.
    Singh, V.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2024, 91 (01) : 44 - 51
  • [49] Complications and failures of titanium elastic nailing in pediatric femur fractures
    Saseendar, S.
    Menon, J.
    Patro, D. K.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2010, 20 (08): : 635 - 644
  • [50] Recurrent rotational deformity of the femur after static locking of intramedullary nails - Case reports
    Krettek, C
    Miclau, T
    Blauth, M
    Lindsey, RW
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (01): : 4 - 8