Simulation Study on Lightning Protection of Distribution Transformer with Zinc Oxide Arrester

被引:0
|
作者
Hou, Mengqian [1 ]
Gao, Houlei [1 ]
Zhang, Shuai [1 ]
Wang, Fei [1 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan, Peoples R China
关键词
zinc oxide arrester; distribution transformer; PSCAD; lightning protection;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Currently, few researches related to lightning protection of distribution transformer with zinc oxide arrester are reported on both home and abroad. This paper establishes a model of zinc oxide arrester and distribution transformer under lightning stroke. In order to verify the lightning protection of zinc oxide arrester to distribution transformer, two distribution network simulations are carried out by using PSCAD. One is the condition without zinc oxide arrester, another one is with zinc oxide arrester to be installed in distribution transformer's high voltage side. Besides, this paper also carries out a distribution network simulation with zinc oxide arrester installed in both high voltage side and low voltage side of a distribution transformer. The importance of zinc oxide arrester for preventing distribution transformer from damage of lighting is shown by comparison of different simulation results.
引用
收藏
页码:1763 / 1767
页数:5
相关论文
共 50 条
  • [41] Applicability Analysis of Simulation Model of Metal Oxide Arrester and Experimental Study
    Liu, Shoubin
    Yao, Yapeng
    Liu, Chongxin
    Zhu, Jiantong
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON COMPUTER MODELING, SIMULATION AND ALGORITHM (CMSA 2018), 2018, 151 : 56 - 62
  • [42] BLOWING OF DISTRIBUTION TRANSFORMER FUSES BY LIGHTNING
    GAIBROIS, GL
    HUBER, WJ
    STOELTIN.HO
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1973, PA92 (06): : 1808 - 1808
  • [43] Influence of Grounding Resistance Connecting to Surge Arrester on Effectiveness of Lightning Protection Caused by Direct Hit for Power Distribution Lines
    Takahashi, Akihisa
    Hidaka, Tetsuya
    Ishimoto, Kazuyuki
    Asakawa, Akira
    ELECTRICAL ENGINEERING IN JAPAN, 2012, 179 (03) : 10 - 22
  • [44] Valve-Type Arrester and Spark Gap Separation in Lightning Protection.
    Neuhaus, Hermann
    Elektrotechnische Zeitschrift Ausgabe B, 1975, 27 (23): : 623 - 628
  • [45] LIGHTNING PROTECTION OF DISTRIBUTION LINES
    MCDERMOTT, TE
    SHORT, TA
    ANDERSON, JG
    IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) : 138 - 146
  • [46] Simulation Study on the Lightning Overvoltage Invasion Control Transformer Intelligent Substation
    Xi, Chuyan
    Hao, Jie
    Zhang, Ying
    ADVANCES IN MATERIALS, MACHINERY, ELECTRONICS II, 2018, 1955
  • [47] Practical methodology for modeling and simulation of a lightning protection system using metal-oxide surge arresters for distribution lines
    Araujo, Marcel A.
    Flauzino, Rogerio A.
    Altafim, Ruy A. C.
    Batista, Oureste E.
    Moraes, Lucas A.
    ELECTRIC POWER SYSTEMS RESEARCH, 2015, 118 : 47 - 54
  • [48] Study of the electric filed around a metal oxide surge arrester: Measurement and simulation
    High Voltage Laboratory, School of Electrical and Computer Engineering, National Technical University of Athens Iroon Polytechneiou 9, 15780, Zografou Campus, Athens, Greece
    Gaodianya Jishu, 2013, 8 (2014-2021):
  • [49] A study of Degradation Characteristics and Diagnostic Method of Lightning Surge Arrester for 6.6 kV Power Distribution Lines
    Yoneda, Yasuaki
    Koga, Yoshiyasu
    Sato, Tomoyuki
    Yokoyama, Shigeru
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [50] Lightning impulse voltage distribution over voltage transformer windings-Simulation and measurement
    Trkulja, Bojan
    Drandic, Ana
    Milardic, Viktor
    Zupan, Tomislav
    Ziger, Igor
    Filipovic-Grcic, Dalibor
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 147 : 185 - 191