Comparison of Outcomes of Glaucoma Drainage Implant Surgery With or Without Prior Failed Trabeculectomy

被引:3
|
作者
Dawson, Emily F. [1 ]
Rosenberg, Nicole C. [1 ,2 ]
Meyer, Alissa M. [1 ]
Culpepper, Brady E. [1 ]
Bolch, Charlotte A. [1 ]
Wilson, Mary K. [1 ]
Nguyen, Phuong T. [1 ]
Rodgers, Cooper D. [1 ]
Smith, Ryan J. [1 ]
Blake, Charles R. [1 ]
Sherwood, Mark B. [1 ]
机构
[1] Univ Florida, Dept Ophthalmol, Gainesville, FL USA
[2] Edward Via Coll Osteopath Med, Spartanburg, SC USA
关键词
glaucoma drainage device; trabeculectomy surgery; intraocular pressure; glaucoma; TUBE; PRESSURE;
D O I
10.1097/IJG.0000000000001852
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: A comparison of 186 glaucoma patients with mixed diagnoses who underwent nonvalved glaucoma drainage device (GDD) implant surgery showed similar long-term intraocular pressure (IOP), medication, and visual acuity (VA) outcomes between those with prior failed trabeculectomy surgery versus those without. Purpose: The purpose of this study was to evaluate whether prior failed trabeculectomy adversely affects the outcome of glaucoma tube surgery. Patients and Methods: A total of 186 eyes of 186 patients who underwent a nonvalved GDD implant surgery by a single surgeon between 1996 and 2015 at a University practice were included. Patients were of mixed diagnoses and over 18 years old. Before the GDD surgery, 65 had a previous failed glaucoma filtering surgery and 121 had no prior glaucoma surgery. Demographic information, preoperative and postoperative IOP, medication, VA, and complications were collected from chart review. Results: No significant difference was noted in mean IOP and mean medication use (13.0 and 12.6 mm Hg on 2.0 and 1.7 medication classes at 5 y postoperatively, respectively), mean VA and change in VA from baseline, or numbers of complications (P>0.05), between eyes that had a prior failed filtration surgery and those that had not. Kaplan-Meier plots for failure over 5 years using a lower limit of <5 mm Hg and an upper limit of >= 18, >= 15, or >= 12 mm Hg did not show a significant difference between groups. Subanalyses were performed to examine only primary glaucoma eyes and results were similar. Further group subanalyses comparing those with baseline IOP >= 25 or <25 mm Hg, age 65 and above or below 65 years and those specifically with Baerveldt 350 mm(2) implants also did not show significant differences. Conclusion: Prior failed filtration surgery does not appear to affect the outcome of future GDD surgery.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [31] Treatment of Uveitis and Outcomes of Glaucoma Drainage Implant Surgery: A Meta-Analysis
    Chaku, Meenakshi
    Bajwa, Asima
    Lee, Jae K.
    Netland, Peter A.
    OCULAR IMMUNOLOGY AND INFLAMMATION, 2020, 28 (05) : 833 - 838
  • [32] Trabeculectomy can be Successful after Glaucoma Drainage Device surgery
    Alizadeh, Reza
    Akil, Handan
    Tan, James C.
    Law, Simon K.
    Caprioli, Joseph
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [33] Recent developments in glaucoma drainage implant surgery
    Whitson, JT
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1999, 39 (03) : 43 - 55
  • [34] Endophthalmitis Following Glaucoma Drainage Implant Surgery
    Kocaturk, Tolga
    Erkan, Erol
    Cakmak, Harun
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2014, 44 (02): : 138 - 143
  • [35] DRAINAGE IMPLANT-SURGERY FOR REFRACTORY GLAUCOMA
    LIEBERMAN, MF
    EWING, RH
    INTERNATIONAL OPHTHALMOLOGY CLINICS, 1990, 30 (03) : 198 - 208
  • [36] Comparison of subconjunctival microinvasive glaucoma surgery and trabeculectomy
    Wagner, Felix M.
    Schuster, Alexander K.
    Munder, Annika
    Muehl, Marius
    Pfeiffer, Norbert
    Hoffmann, Esther M.
    ACTA OPHTHALMOLOGICA, 2022, 100 (05) : E1120 - E1126
  • [37] Outcomes of Gonioscopy-Assisted Transluminal Trabeculotomy in Eyes With Prior Failed Glaucoma Surgery
    Siddhartha, Srihari
    Krishnamurthy, Rashmi
    Dikshit, Siddharth
    Garudadri, Chandrasekar
    Ali, Md Hasnat
    Senthil, Sirisha
    JOURNAL OF GLAUCOMA, 2024, 33 (08) : 612 - 617
  • [38] Failed Ahmed glaucoma valves: trabeculectomy versus repeat shunt surgery
    Einollahi, Neda
    Doozandeh, Azadeh
    Sharifipour, Farideh
    Hassanpour, Kiana
    Rezaei, Javad
    Radmehr, Hamed
    Yazdani, Shahin
    BMC OPHTHALMOLOGY, 2024, 24 (01)
  • [39] Surgical outcomes of combined phacoemulsification and glaucoma drainage implant surgery for Asian patients with refractory glaucoma with cataract
    Chung, AN
    Aung, T
    Wang, JC
    Chew, PTK
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 137 (02) : 294 - 300
  • [40] Clinical Factors Impacting Outcomes From Failed Trabeculectomy Leading to Glaucoma Drainage Device Implantation and Subsequent Penetrating Keratoplasty
    Chen, Jessica L.
    Elhusseiny, Abdelrahman M.
    Khodeiry, Mohamed M.
    Smith, Michael P.
    Sayed, Mohamed S.
    Banitt, Michael
    Feuer, William
    Yoo, Sonia H.
    Lee, Richard K.
    JOURNAL OF GLAUCOMA, 2023, 32 (09) : 800 - 806