Comparison of Outcomes of Glaucoma Drainage Implant Surgery With or Without Prior Failed Trabeculectomy

被引:3
|
作者
Dawson, Emily F. [1 ]
Rosenberg, Nicole C. [1 ,2 ]
Meyer, Alissa M. [1 ]
Culpepper, Brady E. [1 ]
Bolch, Charlotte A. [1 ]
Wilson, Mary K. [1 ]
Nguyen, Phuong T. [1 ]
Rodgers, Cooper D. [1 ]
Smith, Ryan J. [1 ]
Blake, Charles R. [1 ]
Sherwood, Mark B. [1 ]
机构
[1] Univ Florida, Dept Ophthalmol, Gainesville, FL USA
[2] Edward Via Coll Osteopath Med, Spartanburg, SC USA
关键词
glaucoma drainage device; trabeculectomy surgery; intraocular pressure; glaucoma; TUBE; PRESSURE;
D O I
10.1097/IJG.0000000000001852
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis: A comparison of 186 glaucoma patients with mixed diagnoses who underwent nonvalved glaucoma drainage device (GDD) implant surgery showed similar long-term intraocular pressure (IOP), medication, and visual acuity (VA) outcomes between those with prior failed trabeculectomy surgery versus those without. Purpose: The purpose of this study was to evaluate whether prior failed trabeculectomy adversely affects the outcome of glaucoma tube surgery. Patients and Methods: A total of 186 eyes of 186 patients who underwent a nonvalved GDD implant surgery by a single surgeon between 1996 and 2015 at a University practice were included. Patients were of mixed diagnoses and over 18 years old. Before the GDD surgery, 65 had a previous failed glaucoma filtering surgery and 121 had no prior glaucoma surgery. Demographic information, preoperative and postoperative IOP, medication, VA, and complications were collected from chart review. Results: No significant difference was noted in mean IOP and mean medication use (13.0 and 12.6 mm Hg on 2.0 and 1.7 medication classes at 5 y postoperatively, respectively), mean VA and change in VA from baseline, or numbers of complications (P>0.05), between eyes that had a prior failed filtration surgery and those that had not. Kaplan-Meier plots for failure over 5 years using a lower limit of <5 mm Hg and an upper limit of >= 18, >= 15, or >= 12 mm Hg did not show a significant difference between groups. Subanalyses were performed to examine only primary glaucoma eyes and results were similar. Further group subanalyses comparing those with baseline IOP >= 25 or <25 mm Hg, age 65 and above or below 65 years and those specifically with Baerveldt 350 mm(2) implants also did not show significant differences. Conclusion: Prior failed filtration surgery does not appear to affect the outcome of future GDD surgery.
引用
收藏
页码:585 / 595
页数:11
相关论文
共 50 条
  • [1] Postoperative management of trabeculectomy and glaucoma drainage implant surgery
    Panarelli, Joseph F.
    Nayak, Natasha V.
    Sidoti, Paul A.
    CURRENT OPINION IN OPHTHALMOLOGY, 2016, 27 (02) : 170 - 176
  • [2] Comparison between surgical outcomes of glaucoma drainage implant surgery performed with and without intraluminal stent
    Tao, Lingwei W.
    Atik, Alp
    Kwon, Hye J.
    Green, Catherine
    Coote, Michael
    Kong, Yu X. G.
    Ruddle, Jonathan B.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2020, 48 (04): : 525 - 528
  • [3] Trabeculectomy Outcomes After Glaucoma Drainage Device Surgery
    Alizadeh, Reza
    Akil, Handan
    Tan, James
    Law, Simon K.
    Caprioli, Joseph
    JOURNAL OF GLAUCOMA, 2018, 27 (02) : 133 - 139
  • [4] Outcomes of Glaucoma Drainage Implant Surgery in Uveitic Glaucoma
    Huh, Eun Sara
    Sambhara, Deepak
    Aref, Ahmad
    Vajaranant, Thasarat S.
    Wilensky, Jacob T.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2014, 55 (13)
  • [5] Kahook Dual Blade goniotomy after failed trabeculectomy or glaucoma drainage implant in patients with uveitic glaucoma
    Krause, Michael Allen
    Lowder, Careen Y.
    Eisengart, Jonathan
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2020, 61 (07)
  • [6] Comparison of refractive outcomes after combined cataract and glaucoma surgery: trabeculectomy and glaucoma drainage device implantation
    Asano, Shotaro
    Koh, Teck Chang Victor
    Aquino, Maria Cecilia
    Lim, Ka-Ann Dawn
    Sng, Chelvin Cheryl Anges
    Loon, Seng Chee
    Chew, Tec Kuan Paul
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (09): : 1133 - 1138
  • [7] Surgical outcomes of trabeculectomy and glaucoma drainage implant for uveitic glaucoma and relationship with uveitis activity
    Kwon, Hye Jin
    Kong, Yu Xiang George
    Tao, Lingwei William
    Lim, Lyndell L.
    Martin, Keith R.
    Green, Catherine
    Ruddle, Jonathan
    Crowston, Jonathan G.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2017, 45 (05): : 472 - 480
  • [8] Long-term results of non-valved Glaucoma drainage implant surgery and glaucoma drainage implant combined with trabeculectomy
    Hamanaka, Teruhiko
    Otora, Keiko
    Ono, Koichi
    Ishida, Nobuo
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2014, 62 (09) : 911 - 916
  • [9] Outcomes of Glaucoma Drainage Implant Surgery Performed by Residents
    Lee, Jennifer
    Choi, John
    Tai, Tak Yee Tania
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [10] Outcomes of inferonasal Baerveldt glaucoma drainage implant surgery
    Harbick, KH
    Sidoti, PA
    Budenz, DL
    Venkatraman, A
    Bruther, M
    Grayson, DK
    Ko, A
    Yi, GN
    JOURNAL OF GLAUCOMA, 2006, 15 (01) : 7 - 12