Enantiospecific determination of arotinolol in rat plasma by LC-MS/MS: Application to a stereoselective pharmacokinetic study

被引:11
|
作者
Qian, Zheyuan [1 ,2 ]
Xu, Yanhai [1 ]
Zheng, Leyi [1 ]
Zhang, Jingbo [1 ]
Hong, Zhanying [1 ]
Shen, Xiaohang [2 ]
机构
[1] Second Mil Med Univ, Sch Pharm, Shanghai Key Lab Phamaceut Metabol Res, Shanghai 200433, Peoples R China
[2] WuXi AppTec Co Ltd, Bioanalyt Serv, Shanghai 200131, Peoples R China
关键词
LC-MS/MS; Arotinolol enantiomers; Stereoselective pharmacokinetics; LIQUID-CHROMATOGRAPHIC DETERMINATION; BIOLOGICAL SAMPLES; MAIN METABOLITE; AC-623; PHASE; DRUGS;
D O I
10.1016/j.jpba.2014.09.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and selective liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and fully validated for quantification of arotinolol enantiomers in rat plasma using haloperidol as the internal standard. After solid phase extraction of 50.0 mu L rat plasma in 96 well plate, a baseline resolution of arotinolol enantiomers was achieved on a CHIRALPAK AD-H column using the mobile phase of n-hexane and ethanol in 0.02% diethylamine (20:80, v/v) at a flow rate of 0.550 mL/min within 11.0 min. Acquisition of mass spectrometric data was performed on a triple-quadrupole mass spectrometer in multiple-reaction-monitoring (MRM) mode with an ESI source using the transition m/z 372.1 -> 316.1 for (+/-)-arotinolol and m/z 376.1 -> 165.1 for haloperidol. The calibration curves of both enantiomers were linear over the range of 1.00-200.0 ng/mL (r(2) > 0.992) and the lower limit of quantification was 1.00 ng/mL. Intra- and inter-day precision ranged from 5.6% to 8.9% for R-( -)-arotinolol and 4.6-7.4% for S-(+)-arotinolol. Accuracy varied from 0.0% to 7.0% for R-(-)-arotinolol and 5.0-10.0% for S-(+)-arotinolol. For R-(-)-arotinolol, the recovery ranged from 87.2% to 99.2% and the matrix factor was 1.03-1.09; for S-(+)-arotinolol, the recovery ranged from 88.0% to 92.4% and the matrix factor was 0.84-0.95, both were not concentration dependent. The method was demonstrated with acceptable accuracy, precision and specificity for the determination of arotinolol enantiomers and has been successfully applied to a stereoselective pharmacokinetic study. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:299 / 304
页数:6
相关论文
共 50 条
  • [21] LC-MS/MS METHOD FOR DETERMINATION OF FORSYTHIASIDE IN RAT PLASMA AND ITS APPLICATION TO A PHARMACOKINETIC STUDY
    Chang, Qi
    Wang, Geng Nan
    Zuo, Zhong
    Wang, Yu Qi
    Sun, Lan
    DRUG METABOLISM REVIEWS, 2008, 40 : 46 - 47
  • [22] Quantitative determination of euphol in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
    Xie, Xu
    Li, Yongning
    Gao, Dongna
    Zhang, Yu
    Ren, Yanbo
    BIOMEDICAL CHROMATOGRAPHY, 2014, 28 (09) : 1229 - 1234
  • [23] Quantitative determination of glaucocalyxin A in rat plasma by LC-MS/MS: Application to a preclinical pharmacokinetic study
    Ren, Lili
    Ma, Bo
    Chen, Guoguang
    Zhang, Qi
    Wei, Ping
    Liu, Yinhui
    Li, Jing
    ANALYTICAL METHODS, 2013, 5 (18) : 4890 - 4897
  • [24] Determination of aloesone in rat plasma by LC-MS/MS spectrometry and its application in a pharmacokinetic study
    Ren, Xikang
    Wang, Zheng
    Wang, Xuesong
    Li, Youbin
    Tan, Yinfeng
    BIOANALYSIS, 2024, 16 (10) : 453 - 460
  • [25] LC-MS Determination of Crizotinib in Rat Plasma and its Application to a Pharmacokinetic Study
    Huang, Xueli
    Cai, Jinzhang
    Wang, Xiaoyuan
    LATIN AMERICAN JOURNAL OF PHARMACY, 2014, 33 (07): : 1188 - 1192
  • [26] Determination of Itraconazole in Rat Plasma by LC-MS and its Application to Pharmacokinetic Study
    Deng, Mingjie
    Li, Ping
    Zhang, Qingwei
    Bao, Shihui
    Lin, Guanyang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2013, 32 (05): : 769 - 773
  • [27] LC-MS/MS determination of pogostone in rat plasma and its application in pharmacokinetic studies
    Chen, Haiming
    Li, Yucui
    Wu, Xiaoli
    Li, Chuwen
    Li, Qingguo
    Qin, Zhen
    Yi, Yuyang
    Chen, Jiannan
    Lai, Xiaoping
    Su, Ziren
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (09) : 1092 - 1099
  • [28] LC-MS/MS determination of etravirine in rat plasma and its application in pharmacokinetic studies
    Abobo, Cyril V.
    Wu, Lei
    John, Jyothy
    Joseph, Mathew K.
    Bates, Theodore R.
    Liang, Dong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (30): : 3181 - 3186
  • [29] LC-MS/MS determination of nevadensin in rat plasma and its application in pharmacokinetic studies
    Liu, Hongju
    Yan, Chong
    Li, Chunmin
    Lin, Li
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2013, 74 : 56 - 61
  • [30] Enantioseparation and Determination of Penconazole in Rat Plasma by Chiral LC-MS/MS: Application to a Stereoselective Toxicokinetic Study
    Ma, Siman
    Lun, Jia
    Liu, Yanru
    Jiang, Zhen
    Guo, Xingjie
    MOLECULES, 2020, 25 (13):