Quantitative Analysis of Airway Tree in Low-dose Chest CT with a New Model-based Iterative Reconstruction Algorithm: Comparison to Adaptive Statistical Iterative Reconstruction in Routine-dose CT

被引:3
|
作者
Jia, Yongjun [1 ,2 ]
Ji, Xing [3 ]
He, Taiping [2 ]
Yu, Yong [2 ]
Yu, Nan [2 ]
Duan, Haifeng [2 ]
Guo, Youmin [1 ]
机构
[1] Xi An Jiao Tong Univ, Affiliated Hosp 1, Dept Radiol, Yanta Western Rd, Xian 710061, Shaanxi, Peoples R China
[2] Shaanxi Chinese Med Univ, Affiliated Hosp, Dept Radiol, Xianyang 712000, Peoples R China
[3] Yanan Univ, Affiliated Hosp, Dept Radiol, Yanan 716000, Peoples R China
关键词
Model-based iterative reconstruction; computer-aided detection; tomography; X-ray computed; radiation dosage; COMPUTER-AIDED DETECTION; ABDOMINAL CT; IDENTIFICATION; REDUCTION; WALL;
D O I
10.1016/j.acra.2018.03.021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: We aimed to evaluate a new model-based iterative reconstruction (MBIRn) algorithm either with spatial resolution and noise reduction balance (MBIRSTND) or spatial resolution preference (MBIRRP20) for quantitative analysis of airway in low-dose chest computed tomography (CT) with a computer-aided detection (CAD) software, in comparison to adaptive statistical iterative reconstruction (ASIR) in routine-dose CT. Methods: Thirty patients who underwent both the routine-dose (noise index [NI] = 14 HU) and low-dose (at 30% level with NI = 28 HU) CT examination for pulmonary disease were included. Image acquisition was performed with 120 kVp tube voltage and automatic tube current modulation. Routine-dose scans were reconstructed with ASIR, whereas low-dose scans were reconstructed with ASIR, MBIRSTND, and MBIRRP20. Airway dimensions of the right middle lobe bronchus from the four reconstructions were measured using CAD software. Two radiologists used a semiquantitative 5 scoring criteria (-2, inferior to; +2, superior to; -1 slightly inferior to; +1, slightly superior to; and 0, equal to ASIR in routine-dose CT) to rate the subjective image quality of MBIRSTND\ and MBIRRP20 of airway trees. The paired t test and Wilcoxon signed-rank test were used for statistical comparison. Results: The low-dose CT provided 70.76% dose reduction compared to the routine-dose CT (0.88 +/- 0.83 mSv vs 3.01 +/- 1.89 mSv). MBIRSTND and MBIRRP20 with low-dose CT provided longer bronchial length measurements and were better in measurement variability and continuity and completeness of bronchial walls than ASIR in routine-dose CT (P < .05). MBIRSTND was better for subjective noise and MBIRRP20 for showing distal branches. Conclusions: MBIRSTND and MBIRRP20 algorithms provide better airway quantification at 30% of the radiation dose, compared to ASIR at routine-dose CT.
引用
收藏
页码:1526 / 1532
页数:7
相关论文
共 50 条
  • [31] Reducing Radiation Dose at Chest CT: Comparison Among Model-based Type Iterative Reconstruction, Hybrid Iterative Reconstruction, and Filtered Back Projection
    de Margerie-Mellon, Constance
    de Bazelaire, Cedric
    Montlahuc, Claire
    Lambert, Jerome
    Martineau, Antoine
    Coulon, Philippe
    de Kerviler, Eric
    Beigeman, Catherine
    ACADEMIC RADIOLOGY, 2016, 23 (10) : 1246 - 1254
  • [32] QUANTIFICATION OF EMPHYSEMA USING LOW-DOSE CHEST CT: EFFECT OF ITERATIVE RECONSTRUCTION
    Park, K. J.
    Cho, J. Y.
    RESPIRATORY MEDICINE, 2017, 132 : 274 - 274
  • [33] A phantom study of the performance of model-based iterative reconstruction in low-dose chest and abdominal CT: When are benefits maximized?
    Moloney, F.
    Twomey, M.
    James, K.
    Kavanagh, R. G.
    Fama, D.
    O'Neill, S.
    Grey, T. M.
    Moore, N.
    Murphy, M. J.
    O'Connor, O. J.
    Maher, M. M.
    RADIOGRAPHY, 2018, 24 (04) : 345 - 351
  • [34] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Ji Yung Choo
    Jin Mo Goo
    Chang Hyun Lee
    Chang Min Park
    Sang Joon Park
    Mi-Suk Shim
    European Radiology, 2014, 24 : 799 - 806
  • [35] Quantitative analysis of emphysema and airway measurements according to iterative reconstruction algorithms: comparison of filtered back projection, adaptive statistical iterative reconstruction and model-based iterative reconstruction
    Choo, Ji Yung
    Goo, Jin Mo
    Lee, Chang Hyun
    Park, Chang Min
    Park, Sang Joon
    Shim, Mi-Suk
    EUROPEAN RADIOLOGY, 2014, 24 (04) : 799 - 806
  • [36] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [37] Comparison of low-dose CT with adaptive statistical iterative reconstruction and conventional filtered back projection in whole body PET/CT
    Tang, Yongjin
    Ling, Xueying
    Xiao, Zeyu
    Shang JingJie
    Xu, Hao
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [38] Comparison of Model-Based Iterative Reconstruction, Adaptive Statistical Iterative Reconstruction, and Filtered Back Projection for Detecting Hepatic Metastases on Submillisievert Low-Dose Computed Tomography
    Son, Jung Hee
    Kim, Seung Ho
    Yoon, Jung-Hee
    Lee, Yedaun
    Lim, Yun-Jung
    Kim, Seon-Jeong
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2017, 41 (04) : 644 - 650
  • [39] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [40] Low-dose CT statistical iterative reconstruction via modified MRF regularization
    Hong Shangguan
    Zhang, Quan
    Liu, Yi
    Cui, Xueying
    Bai, Yunjiao
    Gui, Zhiguo
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2016, 123 : 129 - 141