Readout System for Arrays of Frisch-ring CdZnTe Detectors

被引:0
|
作者
Cui, Y. [1 ]
Bolotnikov, A. E. [1 ]
Camarda, G. S. [1 ]
Carini, G. A. [1 ]
De Geronimo, G. [1 ]
O'Connor, P. [1 ]
James, R. B. [1 ]
Kargar, A. [2 ]
Harrison, M. J. [2 ]
McGregor, D. S. [2 ]
机构
[1] Brookhaven Natl Lab, Upton, NY 11973 USA
[2] Kansas State Univ, Manhattan, KS 66506 USA
关键词
CdZnTe; Data Acquisition System; Frisch-ring detector;
D O I
10.1109/NSSMIC.2006.353790
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Frisch-ring CdZnTe detectors have demonstrated good energy resolution for identifying isotopes, <1% FWHM at 662 keV, and good efficiency for detecting gamma rays. We will fabricate and test at Brookhaven National Laboratory an integrated module of a 64-element array of 6x6x12 mm(3) Frisch-ring detectors, coupled with a readout electronics system. It supports 64 readout channels, and includes front-end electronics, signal processing circuit, USB interface and high-voltage power supply. The data-acquisition software is used to process the data stream, which includes amplitude and timing information for each detected event. This paper describes the design and assembly of the detector modules, readout electronics, and a conceptual prototype system. Some test results are also reported.
引用
收藏
页码:3675 / 3679
页数:5
相关论文
共 50 条
  • [41] A generic readout system for astrophysical detectors
    Doumayrou, E.
    Lortholary, M.
    MILLIMETER, SUBMILLIMETER, AND FAR-INFRARED DETECTORS AND INSTRUMENTATION FOR ASTRONOMY VI, 2012, 8452
  • [42] A READOUT SYSTEM FOR MICROSTRIP SILICON DETECTORS
    YU, Z
    SEGEL, RE
    CHEN, FJ
    HEIMBERG, P
    BENT, RD
    BLOMGREN, J
    NANN, H
    SUN, C
    REHM, KE
    HARDIE, G
    BROWN, JD
    JACOBSEN, E
    HOMOLKA, J
    SCHNEIDER, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 351 (2-3): : 460 - 462
  • [43] Single-charge-carrier-type sensing with an insulated Frisch ring CdZnTe semiconductor radiation detector
    McNeil, WJ
    McGregor, DS
    Bolotnikov, AE
    Wright, GW
    James, RB
    APPLIED PHYSICS LETTERS, 2004, 84 (11) : 1988 - 1990
  • [44] New Myocardial SPECT System with CdZnTe Semiconductor Detectors
    Ogawa, Koichi
    Ozaku, Yuta
    Nyui, Yoshiyuki
    Fukushi, Masahiro
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2553 - 2556
  • [45] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    甘波
    魏廷存
    高武
    胡永才
    Journal of Semiconductors, 2016, (06) : 181 - 187
  • [46] A digital pulse processing system dedicated to CdZnTe detectors
    Montémont, G
    Moulin, C
    Isard, K
    Verger, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4307 - 4311
  • [47] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    Gan Bo
    Wei Tingcun
    Gao Wu
    Hu Yongcai
    JOURNAL OF SEMICONDUCTORS, 2016, 37 (06)
  • [48] Design and performances of a low-noise and radiation-hardened readout ASIC for CdZnTe detectors
    甘波
    魏廷存
    高武
    胡永才
    Journal of Semiconductors, 2016, 37 (06) : 181 - 187
  • [49] A digital pulse processing system dedicated to CdZnTe detectors
    Montémont, G
    Moulin, C
    Isard, K
    Verger, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 2017 - 2022
  • [50] Multichannel implementation of ROTOR amplifier for the readout of silicon drift detectors arrays
    Fiorini, C
    Longoni, A
    Buttler, W
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (04) : 1763 - 1768