Harmonic technology versus neodymium-doped yttrium aluminium garnet laser and electrocautery for lung metastasectomy: an experimental study

被引:18
|
作者
Fiorelli, Alfonso [1 ]
Accardo, Marina [2 ]
Carelli, Emanuele [1 ]
Del Prete, Assunta [1 ]
Messina, Gaetana [1 ]
Reginelli, Alfonso [3 ]
Berritto, Daniela [3 ]
Papale, Ferdinando [4 ]
Armenia, Emilia [4 ]
Chiodini, Paolo [5 ]
Grassi, Roberto [3 ]
Santini, Mario [1 ]
机构
[1] Univ Naples 2, Thorac Surg Unit, Piazza Miraglia 2, I-80138 Naples, Italy
[2] Univ Naples 2, Morphopatol Unit, Naples, Italy
[3] Univ Naples 2, Radiol Unit, Naples, Italy
[4] Univ Naples 2, Dept Biotechnol, Naples, Italy
[5] Univ Naples 2, Med Stat Unit, Naples, Italy
关键词
Harmonic technology; Electrocautery; Laser; Lung resection; Wedge resection; LATERAL THERMAL-DAMAGE; ND-YAG LASER; ABDOMINAL-WALL; NDYAG LASER; SCALPEL; RESECTIONS; TISSUE; LOBECTOMY; SYSTEM;
D O I
10.1093/icvts/ivw067
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES: We compared the efficacy of non-anatomical lung resections with that of three other techniques: monopolar electrocautery; neodymium-doped yttrium aluminium garnet laser and harmonic technology. We hypothesized that the thermal damage with harmonic technology could be reduced because of the lower temperatures generated by harmonic technology compared with that of other devices. METHODS: Initial studies were performed in 13 isolated pig lungs for each group. A 1.5-cm capsule was inserted within the lung to mimic a tumour and a total of 25 non-anatomical resections were performed with each device. The damage of the resected lung surface and of the tumour border were evaluated according to the colour (ranging from 0-pink colour to 4-black colour), histological (ranging from Score 0-no changes to Score 3-presence of necrotic tissue) and radiological (ranging from Score 0-isointense T-2 signal at magnetic resonance imaging to Score 3-hyperintense T-2 signal) criteria. A total of seven non-anatomical resections with harmonic technology were also performed in two live pigs to assess if ex vivo results could be reproducible in live pigs with particular attention to haemostatic and airtightness properties. RESULTS: In the ex vivo lung, there was a statistical significant difference between depth of thermal damage (P < 0.0001) in electrocautery (1.3 [1.2-1.4]), laser (0.9 [0.6-0.9]) and harmonic (0.4 [0.3-0.5]) groups. Electrocautery had a higher depth of thermal damage compared with that of the laser (P = 0.01) and harmonic groups (P = 0.0005). The harmonic group had a less depth of thermal damage than that of the laser group (P = 0.01). Also, histological damages of tumour borders (P < 0.001) and resected lung surface (P < 0.001), radiological damage of tumour borders (P < 0.001) and resected lung surface (P < 0.001) and colour changes (P < 0.001) were statistically different between three study groups. Resections of in vivo pig lungs showed no bleeding; 2 of 7 cases of low air leaks were found; however, they ceased by sealing lung parenchyma with harmonic technology. CONCLUSIONS: Our experimental data support the resections performed with the use of harmonic technology. The lack of severe tissue alterations could favour healing of parenchyma, assure air tightness and preserve functional lung parenchyma. However, randomized controlled studies are needed in an in vivo model to corroborate our findings.
引用
收藏
页码:47 / 56
页数:10
相关论文
共 50 条
  • [41] Energy analysis and quality evaluation of pulsed neodymium-doped yttrium aluminium garnet laser cladding ceramic-metal composite coating on aluminium alloys
    Chen, SL
    Hsu, RL
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART B-JOURNAL OF ENGINEERING MANUFACTURE, 1999, 213 (01) : 29 - 40
  • [42] Graphite Application and Different Powers of Neodymium-Doped Yttrium Aluminium Garnet (Nd:YAG) Laser on Dentin Surface Changes: A Scanning Electron Microscopy Study
    Birang, Reza
    Yaghini, Jaber
    Fakhari, Elham
    Hasheminia, Seyed Mohsen
    Mousavi, Maryam
    Farhadzadeh, Mahnaz
    Birang, Ehsan
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2012, 3 (04) : 153 - 159
  • [43] Clinical Evaluation of the Efficacy of Neodymium-Doped Yttrium Aluminium Garnet (Nd:YAG) Laser Therapy and Sensikin (R) in Treatment of Dentine Hypersensitivity
    Abed, Ahmad Moghareh
    Naghsh, Narges
    Birang, Reza
    Shafiei, Fatemeh
    Seifi, Massoud
    Yaghini, Jaber
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2012, 3 (02) : 61 - 66
  • [44] Picosecond 532 nm Neodymium-Doped Yttrium Aluminium Garnet Laser for the Treatment of Solar Lentigines in Darker Skin Types: Safety and Efficacy
    Guss, Lark
    Goldman, Mitchel P.
    Wu, Douglas C.
    DERMATOLOGIC SURGERY, 2017, 43 (03) : 456 - 459
  • [45] Long-term result of out-patient neodymium-doped yttrium aluminium garnet laser photocoagulation surgery for patients with epistaxis
    Zhang, J.
    Qiu, R.
    Wei, C.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2016, 130 (01): : 76 - 81
  • [46] A Split-Face, Single-Blinded, Randomized Controlled Comparison of 532 nm Picosecond Neodymium-Doped Yttrium Aluminum Garnet Laser versus 532 nm Q-Switched Neodymium-Doped Yttrium Aluminum Garnet Laser in the Treatment of Solar Lentigines
    Kim, Jung Yup
    Yang, Junghwa
    Huh, Gyoo
    Choi, Young-Jun
    Kim, Won-Serk
    ANNALS OF DERMATOLOGY, 2020, 32 (01) : 8 - 13
  • [47] Rare case of optic fracture in a glass intraocular lens after neodymium-doped yttrium aluminium garnet capsulotomy
    Hsieh, Meng-Wei
    Chien, Ke-Hung
    Liu, Chun-Cheng
    Lu, Da-Wen
    Tai, Ming-Cheng
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (04): : 414 - 415
  • [48] Comparing the effects and safety of dorzolamide hydrochloride plus timolol maleate versus brimonidine after neodymium-doped yttrium aluminium garnet laser capsulotomy posterior capsule opacification
    Cakmak, Kaan
    Erbil, Hasan
    Mesci, Cem
    Korkmaz, Safak
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (05) : 2928 - 2934
  • [49] Quasi-three-level neodymium-doped yttrium aluminum garnet laser emitting at 885 nm
    Lu, Yanfei
    Zhao, Lianshui
    Zhai, Pei
    Xia, Jing
    Li, Shutao
    Fu, Xihong
    OPTICS LETTERS, 2012, 37 (15) : 3177 - 3179
  • [50] Clinical Experience in the Treatment of Different Vascular Lesions Using a Neodymium-Doped Yttrium Aluminum Garnet Laser
    Civas, Ekrem
    Koc, Erol
    Aksoy, Berna
    Aksoy, Hasan Mete
    DERMATOLOGIC SURGERY, 2009, 35 (12) : 1933 - 1941