Climatic influences on the energy performance of air-conditioned buildings

被引:20
|
作者
Lam, JC [1 ]
机构
[1] City Univ Hong Kong, Dept Bldg & Construct, Bldg Energy Conservat Unit, Tat Chee Ave, Kowloon, Peoples R China
关键词
building energy conservation; computer simulations; DOE-2.1E; weather data sets;
D O I
10.1016/S0196-8904(98)00112-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
The computer package DOE-2.1E was used to simulate the thermal and energy performance of fully air-conditioned office buildings in Hong Kong. Seventeen weather data sets from 1979 to 1995 were used for the computer simulation. The objective was to investigate the likely diversity in computer predictions based on different weather years. Predictions of annual cooling loads, peak cooling loads and annual electricity consumption were found to differ by up to about 14%. Implications for the development of a building energy code are discussed. (C) 1998 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:39 / 49
页数:11
相关论文
共 50 条
  • [41] An evaluation of the appropriateness of using overall thermal transfer value (OTTV) to regulate envelope energy performance of air-conditioned buildings
    Yik, FWH
    Wan, KSY
    [J]. ENERGY, 2005, 30 (01) : 41 - 71
  • [42] Modeling of simultaneous heat and moisture transfer in air-conditioned buildings
    Qin, Meng-Hao
    Belarbi, Rafik
    Ait-Mokhtar, Abdelkarim
    [J]. Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL.) : 72 - 75
  • [43] Dynamic evaluation of thermal comfort environment of air-conditioned buildings
    Wang Hanqing
    Huang Chunhua
    Liu Zhiqiang
    Tang Guangfa
    Liu Yingyun
    Wang Zhiyong
    [J]. BUILDING AND ENVIRONMENT, 2006, 41 (11) : 1522 - 1529
  • [44] Indoor air quality and ventilation measurements in nine air-conditioned buildings in Singapore
    Sekhar, SC
    Tham, KW
    Cheong, D
    [J]. PROCEEDINGS OF THE 4TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY, VENTILATION AND ENERGY CONSERVATION IN BUILDINGS, VOLS I-III, 2001, : 715 - 722
  • [45] Comparative assessment of external and internal thermal insulation for energy conservation of intermittently air-conditioned buildings
    Zhang, Xu
    Cheng, Fei
    [J]. JOURNAL OF BUILDING PHYSICS, 2019, 42 (04) : 568 - 584
  • [46] DISINFECTING AIR-CONDITIONED AIR
    不详
    [J]. BMJ-BRITISH MEDICAL JOURNAL, 1962, (5288): : 1357 - +
  • [47] Lighting and energy performance of solar film coating in air-conditioned cellular offices
    Li, DHW
    Lam, JC
    Lau, CCS
    Huan, TW
    [J]. RENEWABLE ENERGY, 2004, 29 (06) : 921 - 937
  • [48] Changing microbial concentrations are associated with ventilation performance in Taiwan's air-conditioned office buildings
    Wu, PC
    Li, YY
    Chiang, CM
    Huang, CY
    Lee, CC
    Li, FC
    Su, HJ
    [J]. INDOOR AIR, 2005, 15 (01) : 19 - 26
  • [49] Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China
    Chan, A. L. S.
    Chow, T. T.
    [J]. APPLIED ENERGY, 2014, 114 : 45 - 57
  • [50] AIR-CONDITIONED HANDPIECE
    KILLILEA, JF
    [J]. JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1945, 32 (15): : 966 - 975