Dentin permeability:: Self-etching and one-bottle dentin bonding systems

被引:36
|
作者
Grégoire, G [1 ]
Joniot, S [1 ]
Guignes, P [1 ]
Millas, A [1 ]
机构
[1] Univ Toulouse 3, Biomat Lab, Fac Odontol, F-31062 Toulouse 4, France
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2003年 / 90卷 / 01期
关键词
D O I
10.1016/S0022-3913(03)00258-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. There are many bonding systems available, with or without a prior acid etch. The mechanisms differ from system to system. Therefore it is important that the clinician know which are the most effective and which provide the best seal. Purpose. This study measured the infiltration of physiological saline solution across dentin after application of self-etching or 1-bottle dentin bonding systems. Material and methods. Thirty-six extracted noncarious human third molars from patients 18 to 25 years old were used for this study. Dentin disks were cut from crown segments parallel to the occlusal surface at the incisal portion of the pulp cavity. The 36 disks, each 1 mm thick, were divided into 6 groups (n = 6 per group), each of which received one of the following dentin bonding systems: Optibond Solo Plus and Excite, which have ethanol as the solvent; Prime & Bond NT, which has acetone as the solvent; Single Bond, which has a mixed solvent; and Clearfil SE Bond or Prompt L-Pop, both self-etching systems The hydraulic conductance, the Volume of fluid transported across a known area of surface (0.28 cm(2)) per unit time under a unit pressure gradient (200 cm H2O), was analyzed for the self-etching and 1-bottle dentin bonding systems with the Flodec apparatus. Both sides of each specimen were etched with 36% phosphoric acid for 30 seconds. Measurements were made every 30 seconds for 15 minutes. The initial measurement served as the reference value for each specimen. The measurements were repeated when a smear layer had been formed and, finally, after one of the 6 bonding systems had been applied. The data were analyzed by use of analysis of variance and a posteriori tests (Fischer's PLSD, Duncan's new multiple range) with alpha=.05. Results. The greatest mean reduction (40%, P<.05) in penetration was observed with the 4 products with conventional etching: Optibond Solo Plus, Single Bond, Excite, and Prime & Bond NT. The self-etching products were associated with reductions of 36% (Clearfil SE Bond) and 16% (Prompt L Pop). Standard deviations were high, 50% of the mean value, except for the Single Bond group (-42 +/- 13) and Prime & Bond NT (-41 +/- 14). Conclusion. Within the limitations of this study, the 4 bonding systems tested with a phosphoric acid before etching provided a greater decrease in dentin permeability than the 2 self-etching systems. The difference in permeability decrease was significant for Prompt L-Pop but not for Clearfil SE Bond.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [41] Comparative investigation of bond strength to dentin of three one-bottle adhesive systems
    Sarajlija, Mubera
    HEALTHMED, 2008, 2 (03): : 114 - 121
  • [42] Dentin demineralization with a self-etching primer.
    Oliveira, SSA
    Marshall, SJ
    Gansky, SA
    Habelitz, S
    Marshall, GW
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A468 - A468
  • [43] Bonding of Self-adhesive (Self-etching) Root Canal Sealers to Radicular Dentin
    Babb, Brian R.
    Loushine, Robert J.
    Bryan, Thomas E.
    Ames, Jason M.
    Causey, Mark S.
    Kim, Jongryul
    Kim, Young Kyung
    Weller, R. Norman
    Pashley, David H.
    Tay, Franklin R.
    JOURNAL OF ENDODONTICS, 2009, 35 (04) : 578 - 582
  • [44] In vivo effect of a self-etching primer on dentin
    Milia, E
    Lallai, MR
    García-Godoy, F
    AMERICAN JOURNAL OF DENTISTRY, 1999, 12 (04): : 167 - 171
  • [45] Bonding of mild self-etching primers/adhesives to dentin with thick smear layers
    Chan, KM
    Tay, FR
    King, NM
    Imazato, S
    Pashley, DH
    AMERICAN JOURNAL OF DENTISTRY, 2003, 16 (05): : 340 - 346
  • [46] Effects of Different Tooth Conditioners on the Bonding of Universal Self-etching Adhesive to Dentin
    Sato, Takaaki
    Takagaki, Tomohiro
    Baba, Yuta
    Vicheva, Martina
    Matsui, Naoko
    Hiraishi, Noriko
    Ikeda, Masaomi
    Nikaido, Toru
    Tagami, Junji
    JOURNAL OF ADHESIVE DENTISTRY, 2019, 21 (01): : 77 - 85
  • [47] Influence of Bonded Enamel Margins on Dentin Bonding Stability of One-Step Self-etching Adhesives
    Torkabadi, Shiva
    Nakajima, Masatoshi
    Ikeda, Masaomi
    Foxton, Richard M.
    Tagami, Junji
    JOURNAL OF ADHESIVE DENTISTRY, 2009, 11 (05): : 347 - 353
  • [48] Water concentration in self-etching primers affects their aggressiveness and bonding efficacy to dentin
    Hiraishi, N
    Nishiyama, N
    Ikemura, K
    Yau, JYY
    King, NM
    Tagami, J
    Pashley, DH
    Tay, FR
    JOURNAL OF DENTAL RESEARCH, 2005, 84 (07) : 653 - 658
  • [49] Comparison of microleakage for three one-bottle and three multiple-step dentin bonding agents
    Pilo, R
    Ben-Amar, A
    JOURNAL OF PROSTHETIC DENTISTRY, 1999, 82 (02): : 209 - 213
  • [50] Shear bond strength of a new one-bottle dentin adhesive
    Swift, EJ
    Bayne, SC
    AMERICAN JOURNAL OF DENTISTRY, 1997, 10 (04): : 184 - 188