An echelle polychromator for inductively coupled plasma optical emission spectroscopy with vacuum ultraviolet wavelength coverage and charge injection device detection

被引:11
|
作者
Luan, S [1 ]
Schleicher, RG [1 ]
Pilon, MJ [1 ]
Bulman, FD [1 ]
Coleman, GN [1 ]
机构
[1] Thermo Elemental, Franklin, MA 02038 USA
关键词
echelle polychromator; charge injection device; vacuum ultraviolet;
D O I
10.1016/S0584-8547(01)00179-3
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The development and evaluation of a simultaneous inductively coupled plasma optical emission spectrometer with vacuum ultraviolet (VUV) wavelength coverage and charge injection device (CID) detection are described. The spectrometer is an echelle polychromator with a magnesium fluoride prism as a cross-disperser. A thin coating of Lumogen, used as a wavelength conversion phosphor, is applied to the surface of the CID detector. The Lumogen coating increases sensitivity in the VUV region dramatically. Wavelengths between 130 and 800 nm can be measured by this spectrometer. A measured spectral bandwidth of 0.006 nm at 134.724 nm is achieved. The analytical performance in radial viewing mode is evaluated. The 3 sigma, detection limit measured for Cl at 134.724 nm in aqueous solution is 100 ng ml(-1). (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1143 / 1157
页数:15
相关论文
共 50 条
  • [31] Analytical performance of inductively coupled plasma spectrometer with charge injection device for rare earth elements
    Xin, RX
    Song, CL
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (08) : 978 - 981
  • [32] Adulteration detection of argan oil by inductively coupled plasma optical emission spectrometry
    Gonzalvez, A.
    Armenta, S.
    de la Guardia, M.
    FOOD CHEMISTRY, 2010, 121 (03) : 878 - 886
  • [33] In-laboratory sensitivity calibration of an optical emission spectroscopy system in vacuum ultraviolet wavelength range
    Soma, Shuntaro
    Kurihara, Kazuaki
    Sasaki, Koichi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (04)
  • [34] Diagnostics of the diamond depositing inductively coupled plasma by electrostatic probes and optical emission spectroscopy
    Teii, K
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1999, 17 (01): : 138 - 143
  • [35] Inductively coupled plasma optical emission spectroscopy as a tool for evaluating lateral flow assays
    DeSousa, Jenna M.
    Jorge, Micaella Z.
    Lindsay, Hayley B.
    Haselton, Frederick R.
    Wright, David W.
    Scherr, Thomas F.
    ANALYTICAL METHODS, 2021, 13 (18) : 2137 - 2146
  • [36] Inductively coupled RF oxygen plasma studied by spatially resolved optical emission spectroscopy
    Kregar, Zlatko
    Krstulovic, Niksa
    Milosevic, Slobodan
    Kenda, Klemen
    Cvelbar, Uros
    Mozetic, Miran
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) : 1368 - 1369
  • [37] A molecular kinetic model for the optical emission spectroscopy technique in inductively coupled nitrogen plasma
    Zhu, Xi-Ming
    Pu, Yi-Kang
    PHYSICS OF PLASMAS, 2006, 13 (06)
  • [38] Analysis of atherosclerosis by inductively coupled plasma optical emission spectroscopy and scanning acoustic microscopy
    Tanoren, Bukem
    Ugurlucan, Murat
    Alkan, Fatma Ates
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2020, 6 (04):
  • [39] Detection and identification of bacteria using direct injection inductively coupled plasma mass spectroscopy
    Gikunju, CM
    Lev, SM
    Birenzvige, A
    Schaefer, DM
    TALANTA, 2004, 62 (04) : 741 - 744
  • [40] WIDE DYNAMIC-RANGE DETECTION WITH A CHARGE INJECTION DEVICE (CID) FOR QUANTITATIVE PLASMA EMISSION-SPECTROSCOPY