AcrySof phakic angle-supported intraocular lens for the correction of high to extremely high myopia: one-year follow-up results

被引:3
|
作者
Yang, Rui-Bo [1 ]
Zhao, Shao-Zhen [1 ]
机构
[1] Tianjin Med Univ, Eye Ctr & Coll Optometry, Tianjin 300384, Peoples R China
关键词
phakic eye; lens; intraocular; high myopia; foldable; angle-supported; LONG-TERM; IMPLANTATION; 5-YEAR; EYES;
D O I
10.3980/j.issn.2222-3959.2012.03.21
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
AIM: To assess the safety, efficacy and predictability of the AcrySof phakic angle-supported intraocular lens (IOL) (Alcon Inc., U.S.A.) for correction of high-to-extremely high myopia in adults. METHODS: In this prospective study performed in Tianjin Medical University Eye Center & College of Optometry, Tianjin, China, 25 eyes of 13 patients were implanted with AcrySof phakic angle-supported IOLs and followed for 1 year postoperatively. Preoperative manifest refractive sphere was (-12.08 +/- 2.44) diopters (D) and cylinder was (-1.35 +/- 0.62)D. Visual acuity, predictability and stability of manifest refraction spherical equivalent (MRSE), adverse events, and endothelial cell density were analyzed during 1-year of follow-up. RESULTS: After 1 year of follow-up, no eyes lost 1 line (best spectacle-corrected visual acuity)BSCVA; an uncorrected visual acuity (UCVA) of 20/20 or better was achieved in 60% of eyes; 100% had an UCVA of 20/40 or better; a BSCVA of 20/30 or better was achieved by 100% of eyes; 84% had a BSCVA of 20/20 or better. The overall mean percentage change in endothelial cell density 1 year after surgery was (-0.27 +/- 3.60)%. Two eyes (8%) had increased intraocular pressure (IOP) on the day of surgery. No pupil ovalization, pupillary block, or retinal detachment events were observed. CONCLUSION: After 1 year of follow-up, the implantation of AcrySof phakic angle-supported IOL is proved to be safe, effective and predictable with minimal complications in patients with high-to-extremely high myopia. Due to the limitation of visiting time, long-term of clinical investigation is necessary to verify the safety and efficacy of this IOL.
引用
下载
收藏
页码:360 / 365
页数:6
相关论文
共 50 条
  • [31] One-year follow-up of a new posterior chamber toric phakic intraocular lens implantation for moderate-to-high myopic astigmatism
    Sucu, M. E.
    Agca, A.
    Tulu, B.
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (09) : 2941 - 2949
  • [32] One-year follow-up of a new posterior chamber toric phakic intraocular lens implantation for moderate-to-high myopic astigmatism
    M. E. Sucu
    A. Agca
    B. Tulu
    International Ophthalmology, 2021, 41 : 2941 - 2949
  • [33] Foldable Artiflex Phakic Intraocular Lens for the Correction of Myopia Two-Year Follow-up Results of a Prospective European Multicenter Study
    Dick, H. Burkhard
    Budo, Camille
    Malecaze, Francois
    Gueell, Josep L.
    Marinho, Antonio A. P.
    Nuijts, Rudy M. M. A.
    Luyten, Gregorius P. M.
    Menezo, Jose L.
    Kohnen, Thomas
    OPHTHALMOLOGY, 2009, 116 (04) : 671 - 677
  • [34] Follow-up Study of More Than 15 Years of an Angle-Supported Phakic Intracalar Lens Model (ZB5M) for High Myopia Outcomes and Complications
    Alio, Jorge L.
    Abbouda, Alessandro
    Pena-Garcia, Pablo
    Huseynli, Samira
    JAMA OPHTHALMOLOGY, 2013, 131 (12) : 1541 - 1546
  • [35] Phacoemulsification of the crystalline lens and implantation of an intraocular lens for the correction of moderate and high myopia:: Four-year follow-up
    Güell, JL
    Rodriguez-Arenas, AF
    Gris, O
    Malecaze, F
    Velasco, F
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (01): : 34 - 38
  • [36] Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design
    Alfonso, Jose F.
    Fernandez-Vega-Cueto, Luis
    Alfonso-Bartolozzi, Belen
    Montes-Mico, Robert
    Fernandez-Vega, Luis
    JOURNAL OF REFRACTIVE SURGERY, 2019, 35 (03) : 169 - +
  • [37] Two-year follow-up of angle supported myopic phakic intraocular lenses
    Allemann, N
    Chamon, W
    Campos, M
    Schor, P
    Nose, W
    Baikoff, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S104 - S104
  • [38] Collagen copolymer toric posterior chamber phakic intraocular lens for myopic astigmatism One-year follow-up
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Fernandes, Paulo
    Gonzalez-Meijome, Jose M.
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04): : 568 - 576
  • [39] Implantation of a diffractive trifocal intraocular lens: One-year follow-up
    Mojzis, Peter
    Majerova, Katarina
    Hrckova, Lucia
    Pinero, David P.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (08): : 1623 - 1630
  • [40] 36 MONTH FOLLOW-UP OF A CONTEMPORARY PHAKIC INTRAOCULAR-LENS FOR THE SURGICAL-CORRECTION OF MYOPIA
    PRAEGER, DL
    MOMOSE, A
    MUROFF, LL
    ANNALS OF OPHTHALMOLOGY, 1991, 23 (01): : 6 - 10